INSTALLATION INSTALLATION
Installing the Boiler
Please check that you are familiar with the installation
requirement before commencing work (pages 11 - 15).
The installation accessories described in the following list are
included in the boiler packaging:
- Hanging bracket
- A paper template (showing the dimensions of the boiler with
5 mm side clearances)
- Connection valves (compression)
- Screws and washers
- Filling loop
- Installation, Servicing and User manual
Method of positioning the boiler on the wall
The paper template can be used to ensure the correct positioning
of kitchen cabinets etc.
The paper template has to be xed to the wall and used to
locate the position of the hanging bracket and the centre for the
ue hole.
Drill and plug the wall and secure the hanging bracket using the
screws provided ensure the hanging bracket is level. Remove
the boiler from its packaging and remove the front casing panel.
Place the boiler on the hanging bracket.
Note: the appliaNce must Not be fitted oN a combustible wall surface.
Connecting the boiler to the system
- Remove the boiler casing as described on page 14
- Remove the caps and connect the valves to the boiler using
the washers provided
- 5 x bre washers for the CH ow and return, cold water inlet, gas
and hot water outlet connections
Safety Valve Discharge
The pressure relief valve pipe is made of copper. It should
terminate below the boiler safely outside the premises. Care
should be taken that it does not terminate over an entrance or
window or where a discharge of heated water could endanger
occupants or passers by.
Fill the central heating and DHW system and bleed air from the
system as described in the Commissioning instructions (page
32).
The system should be carefully checked for leaks, as frequent
relling could cause premature system corrosion or unnecessary
scaling of the heat exchanger. The pipe from the trap should be
connected to a drain as described in the relevant regulations.
Pay special attention not to bend the condensate silicone drain
pipe is such a way as to interrupt the ow. Please only use drain
pipe material compatible with condensate products (refer to BS
6798:2009).
The condensate ow can reach 2 litres/hour because of the
acidity of the condensate products (Ph close to 2), take care
before operation.
See page 15 for condensate discharge options.
Note: Connections viewed from behind boiler
CLAS ONE / CLAS NET ONE
CLAS SYSTEM ONE
Note.
Connections viewed from
behind boiler.
WARNING!
DO NOT APPLY HEAT TO THE COPPER
SAFETY VALVE OUTLET PIPE WHILST IT IS
CONNECTED TO THE 3 BAR SAFETY RELIEF
VALVE.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ariston Clas One wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info