USER’S MANUAL

The boiler is protected from malfunctions by means of internal
checks performed by the electronic P.C.B., which stops the boiler
from operating if necessary. In the event of the boiler being shut
o in this manner, a code appears on the control panel display
which refers to the type of shut-o and the reason behind it.
Two types of shut-o may occur:

This type of error is “volatile”, which means
that the boiler starts up again automatically
as soon as the problem which caused the
shut-o is removed;
and the error
code
(e.g. / ) ash on the
display and the symbol appears.
In fact, soon as the cause of the shut-o
disappears, the boiler starts up again and
continues to operate normally.
If the boiler still indicates a safety shut-o,
switch it o. Make sure the external electric
switch is in the OFF position, shut o the gas valve and contact a
qualied technician.

If the water pressure inside the heating circuit is insucient, the
boiler will perform a safety shut-o.
Code 108 (
/ ) will appear on
the display.
The system may be restarted, re-balancing
the water pressure, by using the lling
procedure - see note 1.
If the re-balancing request is performed
on a frequent basis, switch the boiler o,
bring the external electric switch to the OFF
position, shut o the gas valve and contact
a qualied technician to check for any leaks
of water.
Important
If this shutdown occurs frequently, contact an authorised
service centre for assistance. For safety reasons, the boiler
will allow a maximum of 5 reset operations to take place in 15
minutes (individual presses of the button).
If the shutdown is occasional or an isolated event, this is not
Necessarily a problem.
Anti-frost Device.
The anti-frost function acts on the central heating ow temperature pro-
be, independently from other settings, when the electrical supply is tur-
ned on. If the primary circuit temperature falls below 8°C the pump will
run for 2 minutes.
After the two minutes of circulation (xed) the boiler will check the fol-
lowing:
a - if the central heating ow temperature is > 8°C, the pump stops;
b - if the central heating ow temperature is between 4 and 8°C, the
pump will run for another two minutes;
c - if the central heating ow temperature is
< 4°C, the burner will re (heating posi-
tion) at minimum power until the tempe-
rature reaches 33°C, the burner will go o
and the pump will continue to run for two
minutes.
The activation of the Anti-Frost feature is
symbolised by
.
The anti-frost device activates only when (with
the boiler operating correctly):
- the system pressure is correct;
- the boiler is electrically powered;
- there is a supply of gas.
Operation shutdown error table
Display Description
1 01 Overheating
1 03
Insucient circulation
1 04
1 05
1 06
1 07
1 08 Insucient water pressure - see Note 1
3 05 P.C.B. error
3 06 P.C.B. error
3 07 P.C.B. error
5 01 No ame detection




PURGE




Operation shutdown
This type of error is “non-volatile”, which means that it is not
removed automatically.
On the display ash
and the error code
,
e.g.
Err/501
and appears the symbol
.
In this case the boiler does not restart automatically, but it may be
reset by pressing the
button.
If the problem manifests itself again after several attempts to
reset the appliance, contact a qualied technician.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ariston E-System One wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Ariston E-System One

Ariston E-System One Installationsanweisung - Englisch - 80 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info