Technical characteristics
This appliance conforms with the following
European Community Directives:
- 73/23/EEC of 19/02/73 (Low Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89 (Electromagnetic compatibility)
and subsequent amendments;
- 93/68/EEC of 22/07/93 and subsequent amendments;
- 2002/96/EC
The European Directive 2002/96/EC on Waste Electrical
and Electronic Equipment (WEEE), requires that old
household electrical appliances must not be disposed of
in the normal unsorted municipal waste stream. Old
appliances must be collected separately in order to optimise
the recovery and recycling of the materials they contain
and reduce the impact on human health and the
environment. The crossed out “wheeled bin” symbol on the
product reminds you of your obligation, that when you di-
spose of the appliance it must be separately collected.
Consumers should contact their local authority or retailer
for information concerning the correct disposal of their old
appliance.
Warning: If the hob is fitted above a built-in oven, the hob
and the oven must be connected to the mains separately
for safety reasons and to simplify operations when it is
necessary to pull the oven out for some reason.
Electrical connection
The electrical safety of this appliance can only be guaranteed
if the latter is correctly and efficiently earthed, in compliance
with regulations on electrical safety. Always ensure that this
vital safety measure has been taken. If you have any doubts,
call in a qualified technician to check the electrical system
thoroughly.
The manufacturer denies all responsibility for damage result-
ing from a system which has not been earthed correctly.
• Before powering the appliance, check whether the technical
characteristics featured on the appliance data plate corre-
spond with those of the mains electrical system.
• Check that the current load of the mains supply and of the
power sockets is suitable for the maximum power of the ap-
pliance, indicated on the appliance data plate. If in doubt,
contact a qualified professional.
Disconnect the appliance from the electricity supply before
all operations.
Connect your hob to the electrical system by means of a junc-
tion box: if the appliance is connected permanently to the mains,
an omnipolar circuit breaker, accessible if necessary, with a
minimum contact opening of 3 mm should be installed.
Valid only for models with a power supply cable
Some models are supplied with a single-phase power supply
cable, and should consequently only be connected to the single-
phase mains. Observe the wire colours, as indicated in the dia-
gram attached.
To install the cable, proceed as follows:
unscrew the wire clamp screw and the contact screws.
to make the desired electrical connection (see table), use the
jumpers housed inside the box. Position the power supply
cable wires according to the indications in the table.
once the connections have been made, tighten all the terminal
screws fully.
Fasten the supply cable in place with the clamp and close
the cover of the terminal board.
Valid only for models without a power supply cable
Some models are not fitted with a power supply cable, as the
cable should be sized according to the type of electrical connection
in use (see connection table below). To connect the cable, proceed
as follows:
Using a screwdriver, prise on the side tabs of the terminal
board cover;
Pull open the cover of the terminal board.
Electrical connections
Voltage,
Frequency
Fuses,
Sections
FR-AT-BE-DE-GP--
ES-IE-IL-IS-IT-LU-
RE-FI-GB-GR-PT--
SE-MA-NZ
230V-1+N~50 Hz
25 A*
2,5 mm²
FR-BE-NO
230V-2~50/60 Hz
25 A*
2,5 mm²
FR-BE-CH-DE-AT--
ES-IL-IT-NZ-PT-
MA- LU-SE-IS-NL
400V2-N~50 Hz
16 A*
1,5 mm²
FR-BE-NO
230V3~50 Hz
16 A*
1,5 mm²
NL
230V2+2-N~50 Hz
16 A*
1,5 mm²
CY-AU-NZ-KW-MT
240V-1+N~50 Hz
25 A*
2,5 mm²
* Application of the simultaneity coefficient in accordance with
cei 60335-2-6 norm
LN
12345
L1 L2
1 2 3 4 5
L1 L2 N
1 2 3 4 5
L1 L2 L3
1 2 3 4 5
L1 L2 N2N1
1 2 3 4
5
L N
1 2 3 4 5
BL
N
BR
L
BL
N
BR
L
Collegamenti elettrici Tensione Frequenza Fusibili Sezioni
FR-BE-AT-DE-GR-ES-IL-
IT-NZ-PT-GP-CH-MA-LU-
IE-FI-SE-IS-GB-NL-DK
230V - 1+N~ 50Hz
CY-MT-AU-NZ-KW
240V - 1+N~ 50Hz
25A *
2,5 mm²
FR-BE-NO
230V - 2 ~ 50Hz
BR=BRUN,BL=BLEU
BR=BRUIN, BL=BLAUW
BR=BRAUN, BL=BLAU
BR=BROWN, BL=BLUE
* Applicazione del fattore di simultaneità in conformità alla norma CEI
60335-2-6
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ariston KOT 7424 IO BI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info