Heat pump water heater – INSTALLATION
35
4. INSTALLATION
WARNING! Observe the general warnings and safety instructions listed in the previous
paragraphs and strictly adhere to the indications therein contained.
4.1 Location of the internal unit
WARNING! Prior to starting any installation activities, ensure that the location where the water heater is to be
installed satisfies the following requirements:
a) Respect the Minimum installation dimensions specified in Figure 5,
b) Avoid installing the appliance in rooms which may favour frost build-up. The product is designed for
indoor installations, the product’s safety and performance levels are not guaranteed in the event of
outdoor installation.
c) Ensure that the installation site and the electrical and hydraulic systems to which the appliance must be
connected fully comply with the regulations in force.
d) The chosen site must have, or must be suitable to house, a single-phase 220-230 V ~ 50 Hz power
supply socket.
e) The support surface must ensure a perfectly horizontal operating position, and can withstand the weight
of the water heater filled with water.
f) The chosen site must conform to the appliance’s IP protection rating (protection against the penetration of
liquids) as specified by the regulations in force.
g) The appliance must not be exposed to direct sunlight, even when windows are present.
h) The appliance must not be exposed to particularly aggressive substances such as acidic vapours, dust or
gas-filled environments.
i) The appliance must not be directly installed on lines that are unprotected against overvoltage.
j) The appliance must be installed as close as possible to the points of use to limit heat dispersion along the
piping.
Positioning on the ground – 300 litres floor standing model
a) Once the suitable installation position has been located, remove the packaging and remove the fixings
visible on the pallet where the product is based (fig.6).
b) Fix the feet on the ground (through the appropriate holes) using suitable screws and rawlplugs.
Positioning on the ground – 150-200 litres wall hung model
a) Fix the product through the brackets on a bearing wall, using the installation template printed on the
packaging. For each bracket using two bolts,and two chrome screws concrete type Fischer M10, M12 or
M14, No. 2 nuts M10, M12 or M14, No. 2 washers M10, M12 or M14. Make sure the screws and bolts are
tight. (see Figure 7).
b) This model can be installed on a support tripod only use the appropriate model provided by the
manufacturer of the water heater. In this case the product must be secured to a bearing wall over
the upper bracket, or both.
4.2 Location of the external unit
WARNING! Prior to starting any installation activities, ensure that the location where the water heater is to be
installed satisfies the following requirements:
a) establish the most suitable position on the wall, allowing enough room to easily perform any maintenance
(see fig. 3);
b) Install the outdoor unit on a solid wall in a very secure way, in a place where noise and exhaust air do not
cause trouble. Choose a place that does not obstruct the free passage and which is easy to evacuate the
condensate produced.
c) The plan of operation must be exactly horizontal, check with a level (Fig. 3).
d) Follow the steps and only then start making the connections of the pipes and electric cables;
e) secure the brackets to the wall using suitable fixings for the wall (be careful to cables and pipes in the
wall), use dowels larger than the weight would require: while operating the machine vibrates and must be
installed for years without any screw come loose.
35

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ariston NUOS 200 SPLIT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info