INSTALLATION INSTRUCTIONS
1 - GENERAL INFORMATION
This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or electric hotplate
and can be used either in the extraction mode (ducted to the outside) or in the recircu-lation mode
(internal recycling). Before commencing the installation, consi-deration should be given to the
difficulties to be found during installation and to the bulky weight of the hood. The installation
work must be undertaken by a qualified and competent person in conformity to the rules
concerning the evacuation of contaminated air. The manufacturer disclaims all liability for any
damage or injury caused as a result of not following the instructions for instal-lation contained in
the following text.
2 - COMPONENTS.
The hood comprises (fig. 1):
2.1 - No. 1 canopy C including controls, illumination and fan unit
2.2 - No. 1 telescopic chimney stack comprising:
No. 1 top section S
No. 1 bottom section I
2.3 - No. 1 evacuation spigot A Ø 120-100
2.4 - No. 1 metal plug T
2.5 - No. 1 plastic bag containing:
screws, plugs, 2 rings D to fix the hood to the wall and documentation
2.6 - No. 1 splashback B (optional).
3 - SAFETY WARNINGS
3.1 - When used in the extraction mode the cooker hood ducting must not be connected to
a flue which is used for exhausting fumes from appliances supplied with energy other
than electric such as a central heating flue or water heating flue.
3.2 -Before connecting to the mains supply ensure that the mains voltage corresponds with
the voltage on the rating plate inside the hood.
3.3 - Connect the cooker hood to the mains via a double pole switch which has 3 mm
clearance between the contacts.
3.4 -The appliance must be earthed.
3.5 - When istalled, the hood must be positioned at least 65 cm above a cooking appliance.
3.6 -Never do flambé cooking under this cooker hood.
3.7 -Never leave frying pans unattended during use as overheated fats and oils may catch
fire.
3.8 -Before carring out any kind of maintenance or cleaning, disconnect the hood from the
mains supply.
3.9 - If the room where the cooker hood is to be used contains a fuel burning appliance
such as a central heating boiler then this must be of the room sealed or balanced flue
type. If other types of flue or appliance are fitted ensure that there is an adequate