Now you have purchased an Ascot product you can rest assured in the
knowledge that as well as your 3 year parts and labour warranty you
have the added peace of mind of dedicated helplines and web support.
What your three year warranty means:
Great care has gone into the manufacture of this product and it should
therefore provide you with years of good service when used properly. In
the event of product failure within its intended use over the course of the
first 3 years after date of purchase, we will remedy the problem as fast as
possible once it has been brought to our attention. In the unlikely event
of such an occurrence, or if you require any information about the
product, please contact us via our helpline support services, details of
which are to be found in this manual.
This warranty does not affect your statutory rights.
2.12 Contents
1 base station
1 external sensor
1 x 1.5v AA batteries for the base station
2 x 1.5v AAA batteries for the external sensor
1 set of operating instructions
Tip: Not included in the pack are further external sensors or sensor
extension cable for the external sensors.
3 Display and function keys
3.1 Base station
Front view of the base station
- Time, date, alarm
Radio clock time / quartz clock
Displays day, month and day of the week
Time in 12 or 24-hour clock format
Time zone setting +/- 12 hours
2 alarm settings with snooze function
Transmitter call function for the radio clock time
Radio tower symbol
- External temperature and air humidity display
External temperature for up to 3 external sensors:
- current reading
- min/max memory
- display in °C / °F
- trend display:
External air humidity for up to 3 external sensors:
- current reading
- min/max memory
- trend display
Display of selected external sensor or automatic switching between
sensors
Low battery indicator for external sensors
- Internal temperature and air humidity display
Internal temperature: - current reading
- min/max memory
- display in °C / °F
- trend display
Interior air humidity: - current reading
- min/max memory
- trend display
Low battery indicator for base station
- Weather forecast
Weather forecast with 5 symbols
Weather tendency
- Air pressure
Air pressure display:
- Display in hPa
- min/max memory
- Air pressure diagram
Display of the development of air pressure over the past
12 hours in 5 stages
- Moon phase, time of sunrise and sunset, time of moonrise and
moonset
Phase of the moon
Time of sunrise and sunset
Time of moonrise and moonset
Select region and city
- Light
View of base station from above
Rear view of base station
3.2 External sensor
Front view of external sensor
Rear view of external sensor
4 Putting the device into operation
We recommend that you read the operating instructions carefully before
using the Weather Station for the first time. In particular, before using
the device for the first time, please read point 3.1, Base station and point
3.2, External sensor to become familiar with the Weather Station’s
function keys.
Put the device into operation on a table where you can lay the base
station and the external sensor next to each other or stand them upright
1. Remove the battery compartment cover located at the rear of
the base station.
2. Also remove the battery compartment cover located at the rear
of the external sensor. First push the retractable stand in the
direction of the arrow so that you can remove the battery
compartment cover. Please unscrew the battery compartment
cover using a small screwdriver.
Tip: Please note that the batteries must be inserted in the base
station first and then in the external sensor otherwise the base
station may fail to receive the external sensor’s signal.
3. First insert the 2 x 1.5V AA batteries in the base station’s
battery compartment (note +/- polarity).
Tip: Please ensure that the batteries are new and are the correct
size.
When you have inserted the batteries correctly, this will be
confirmed by an audible tone. Now you can close the battery
compartment again with the compartment cover.
4. Then insert the 2 x 1.5V AAA batteries in the external sensor’s
battery compartment (note +/- polarity). Leave the battery
compartment open so that you can set more settings.
Tip: Please ensure that the batteries are new and are the correct
size.
1
4
5
3
2
6
7
1
2
3
4
5
6
7
Connector for
sensor extension
cable (not
included)
Display for external
temperature in °C/°F
and humidity
TX ke
y
C/F ke
y
Retractable
stan
d
Channel
Hanging kit for
wall assembl
y
Batter
y
Batter
y
com
p
artment
Screws for battery
compartment cover
Battery
com
p
artment
Battery-change
indicator
Stan
d
Transmitting
signal indicator
Channel
indicator
LIGHT/SNOOZE key
SET/ZONE key
CHANNEL key
ALARM key
MIN/MAX key
CLEAR/SET/BARO
key
‚+ key ‚- key
B key B key
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ascot AUK-WS-11 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info