EF1210 C
OMMAND
S
ET
R
EFERENCE
ASPI Digital - The Sound of DSP Technical Support: 404.892.3200 59
AECS
N
-
SET
SUPPRESSION
MODE
ON
CHANNEL
N
TO
NORMAL
OR
AGGRESSIVE
.
Suppression Level
Selection
The EF1210 has been designed and carefully optimized to provide the best possible
balance between removing as much vestigial echo as possible and maintaining natu-
ral, full-duplex performance when both parties speak at the same time or one party
tries to interrupt the other. As designed, the EF1210 should have no difficulty com-
pletely removing audible echo and adapting almost instantaneously to movements
and level changes within the room as long as the EF1210 is set up correctly. How-
ever, it is possible that some room environments may be so harsh as to strain the
boundaries of the operation of the EF1210. This may occur if the room is exceed-
ingly reverberant, the room acoustic gain limit is exceeded, or there is an excessive
amount of background room noise which results in a low signal-to-noise ratio on both
local speech and echo signals.
In conditions of excessive background noise, the signal-to-noise ratio of the local
speech signal can drop so low as make the conferencing system virtually unusable. In
such conditions, it is difficult for the AEC to cancel echoes much below the noise
floor. While the EF1210’s superior noise cancellation subsystem can reduce the
objectionable audible impact of high room noise to make the conferencing experience
more enjoyable and less fatiguing, in certain very harsh conditions this may mean that
the residual echo is now more audible because the noise floor has been so dramati-
cally reduced.
Another difficult situation for the EF1210 arises when the room acoustic gain limit is
approached or exceeded. As the acoustic gain limit is approached, it becomes more
difficult for the EF1210 to adapt to level changes or movement in the room (including
normal conferencing participant movement, movement of papers, etc.) as a result of
which snippets of echo may be heard for longer periods than would be desirable.
Should it be necessary to operate the EF1210 in such hostile conditions, the echo sup-
pression performance of the EF1210 may be enhanced to remove any vestigial traces
of echo, at the expense of doubletalk performance. In aggressive suppression mode,
users on the remote end will hear dropouts and clipping artifacts when they attempt to
talk across a local participant. The AECSn command may be used to select either
normal suppression mode (default) or aggressive suppression mode if required by
harsh room conditions.
The factory default setting for AECS
n
is 0 (normal).
Remote Commands
The following commands can be sent by the remote control device to set the suppres-
sion mode level.
Remote Command Effects
AECS
n
x Set suppression mode on channel n to x.
x is the noise suppression mode (0 = normal; 1 =
aggressive).
AECS
n
? Request AECS status for channel n.
61

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aspi EF1210 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Aspi EF1210

Aspi EF1210 Zusatzinformation - Englisch - 3 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info