In order to obtain an optimal operation of the heat pump, certain norms must be respected:
Use of free chlorine: 0.5 – 2 ppm.
Bromine: 6.6 mg/l max.
pH: Between 7.2 and 7.6
Salt: 4-6 gr/l.
When backwashing the filter of the swimming pool filtration system, the heat pump must be
disconnected.
SPECIFIC
SPECIFIC SPECIFIC
SPECIFIC INSTRUCTIONS:
INSTRUCTIONS:INSTRUCTIONS:
INSTRUCTIONS:
It is obligatory for users contact a specialized company that has
experience installing and repairing heat pumps. Users should not install or repair the heat pump
themselves nor should another person do it.
The operating environment of the unit usually varies between 10 ºC and 35 ºC.
4.
4. 4.
4. START UP OF THE HEAT PUMP
START UP OF THE HEAT PUMPSTART UP OF THE HEAT PUMP
START UP OF THE HEAT PUMP
4.1.
4.1. 4.1.
4.1. INSTALLATION RULES
INSTALLATION RULESINSTALLATION RULES
INSTALLATION RULES
It is necessary to determine the unit location according to certain criteria:
The unit must be secured on a firm and flat surface (concrete or hard steel frame type)
and must be protected from flood risk.
The unit must be installed outdoors, taking advantage of the sun’s direct rays.
Clearance space around the unit is necessary: 0.6 meters at the front, adequate for
servicing, and a minimum of 0.5 meters at the back and sides of the unit.
If the heat pump is to be installed in a garage or under a vertical overhang, the unit
must have a minimum of 2.5 meters clearance at the top.
The air caused by the helix must be directed away from the limits of the work
environment (windows, doors...).
The minimum distance between the heat pump and the rim of the swimming pool must
be at least 3.5 meters (Electrotechnic Regulations for Low Voltage, Supplementary
Technical Instructions, Low Voltage, 31, ITC-BT-31).
The electrical and hydraulic connections must be in accordance to the applicable
regulations (NF C 15 100, EC 1 364). The water tubing must be fixed.
During normal operation of the heat pump, the evaporation coil will produce a certain
amount of water which has to be evacuated. The heat pumps are equipped with a 12
mm diameter adapter drain in 100/150 models and a 19 mm diameter barbed adapter
in 200/250/300 models. This drain is located on the side of the base plate and always
should be free of any obstruction.
It is important to remember that no part of the tubing or hose may be above the level
of the drain hole in the base of the heat pump.
This condensation water does not have to be treated in any special manner.
Keep lawn sprinkler heads from spraying on the heat pump to prevent corrosion and
damage. Use a deflector if needed.
Make sure the heat pump is not located where large amounts of water may run off
from a roof into the unit. Sharp sloping roofs without gutters will allow massive
amounts of rain water, mixed with debris from the roof, to be forced through the unit.
4.2.
4.2. 4.2.
4.2. HYDRAULIC CONNECTIONS
HYDRAULIC CONNECTIONSHYDRAULIC CONNECTIONS
HYDRAULIC CONNECTIONS
Remove the seals from the three piece connections of the water intake on the heat pump.
Connect the PVC 50 piping water inlets and outlets of the swimming pool to the heat pump inlet
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Astralpool ASTRALPOOL HEAT II wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info