Page 16
Select
Press for approx. 3 seconds
Programming of operating times
62.5
15:30
MO. 22. AUG.;05
°C
TIMEPjOGjAMS
HHCC
TIMEPjOGjAMS
DHW
TIMEPjOGjAMS
Enter operating times level
Standard display
accept
For example unmixed heating circuit HC
accept
With this mode of operation individual programs, other than standard programs for heating and hot-
water mode can be set up. For this purpose after selecting the heating- resp. hot-water circuit the
factory preset standard program (P1) is called an can be overwritten individually.
For programming the operation times, for each week day maximum three heating cycles with one
switch-on and switch-off time each are available. Further more, the heating- resp. hot-water cycle can
be combined with a required room temperature resp. hot-water temperature for the duration of the
cycle.
select program P1...P3, if released
heating circuit
3sec