103
INSTALLATION GUIDE built in HL60..E
Fitting the hob
Above a drawer or fixed decorative trim. Above a 60 cm ATAG oven.
Above an oven of another make with casing cooling.
Ensure that there is a space of at least 10 mm between a drawer and the
hob. Take care that the drawer cannot put any mechanical pressure on
the connection cable.
Make an opening in the side wall of the kitchen cupboard for leading
the connection cable through (for building-in in combination with an
oven). This is necessary when the plug can no longer be reached after
building in. Wall socket and plug must be accessible at all times.
A certain height under the worktop is necessary if the hob is installed
above an oven. This height under the worktop depends on the
following:
– Worktop thickness;
– Installed height of the hob (see table);
– Height of oven at highest point (not including the operating
panel).
The required height under the worktop is the height of the oven at
the highest point plus the installed height of the hob less the worktop
thickness.
102
INSTALLATION GUIDE
Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately
(see table). Also saw out any partitions that may be present.
The distance from the saw line to the rear wall and/or side wall is
indicated in the table.
Table
Space to be left free around the appliance
built in HL60..E
Type of hob
HL60..E
Appliance width x depth
575 x 505 mm
x
Installation height from top of worktop
56
x
Cut out dimensions width x depth
560 x 490 mm
x
Distance from saw line to rear wall
50 mm
Distance from saw line to side wall
50 mm