GB 18
16 A*
installer's information
connecting up
Electrical connection should be done before installing the appliance in
the cabinet, in compliance with the assembly instructions and with local
regulations.
When the appliance is connected to the power grid, an all-pole cutoff
device (with a contact opening of at least 3 mm) must be installed on
the power side in order to respect safety recommendations.
NOTE: When powering up your appliance, your oven's electronic
system will switch on. Lighting will be disactivated for a few sec-
onds.
We cannot be held responsible for any accident resulting from an
inexistent, defective or incorrect ground lead.
If the power supply cable is damaged, it must be replaced by the
manufacturer or its after-sales service department to prevent haz-
ards.
The safety wire (green-yellow) is connected to the appliance's
ground terminal and must be connected to the ground lead of
the electrical set-up.
installer's information
technical details
Operating voltage...................................................220-240 V ~ 50 Hz
Nominal power of grill...........................................................1,5 kW
Total power used in cooking...................................................3,56 kW
Power output in microwaves....................................................1000W
Energy consumption
- while heating to175°C.......................................................0,29 kWh
- to maintain175°C for 1 hour...............................................0,78 kWh
Total.....................................................................................1,07 kWh
Microwaves 1 hour at 1000W............................................2,06 kWh
Effective volume....................................................................32 litres
network voltage
connection
fuse
min.
diameter of cable
220-240V~50Hz
1 Ph + N
1,5 mm²