128520
10
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
- 10 -
GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations.
The appliance has been designed as a exhausting version
(external exhaust), as a filter version (internal air recycle)
cooker hood or as use in homes with centralised vacuum
system.
SAFETY PRECAUTION
1. Take care when the cooker hood is operating
simultaneously with an open fireplace or burner that
depend on the air in the environment and are supplied by
other than electrical energy, as the cooker hood removes
the air from the environment which a burner or fireplace
need for combustion.
The negative pressure in the environment must not
exceed 4 Pa (4 x 10 -5 bar).
Provide adequate ventilation in the environment for a
safe operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
If the power supply cable is damaged it must be replaced
with a cable or a special assembly; both of these are
available direct from the manufacturer or from its special
technical assistance service.
2. WARNING!!
In certain circumstances electrical appliances may
be a danger hazard.
A) Do not check the status of the filters while the
cooker hood is operating
B) Do not touch the light bulbs after appliance use
C) Flambè cooking is prohibited underneath the
cooker hood
D) Avoid free flame, as it is damaging for the filters
and a fire hazard
E) Constantly check food frying to avoid that the
overheated oil may become a fire hazard
F) Disconnect the electrical plug prior to any
maintenance
This appliance conforms to the European Directive EC/
2002/96, Waste Electrical and Electronic Equipment
(WEEE). By making sure that this appliance is disposed
of in a suitable manner, the user is helping to prevent
potential damage to the environment or to public health.
The
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to a
suitable electric and electronic appliance recycling
collection point.
Follow local guidelines when disposing of waste.
For more information on the treatment, re-use and
recycling of this product, please contact your local
authority, domestic waste collection service or the shop
where the appliance was purchased.
ENGLISH
INSTALLATION INSTRUCTIONS
• Electric Connection
The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load
indicated on the description label. Where a plug is provided,
the cooker hood must be installed in order that the plug is
easily accessible.
An omnipolar switch with a minimum aperture of 3mm
between contacts, in line with the electrical load and local
standards, must be placed between the appliance and the
network in the case of direct connection to the electrical
network.
• The appliance must be installed at a minimum height of
700 mm from an cooker stove in case of a gashob or an
electrical hob.
If a connection tube composed of two parts is used, the
upper part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating fumes
from other appliances generated by other than an electrical
source.
INSTALLATION
The following instruction should be followed to carry out
the correct installation of the cooker hood.
1) Mounting of the cooker hood on the lower side of the
cupboard.
2) Selection of the version (extraction or filtration)
Mounting the cooker hood on the lower side of the cupboard.
This appliance must be fitted to a cupboard or other suitable
support. For fixing use 4 screws suitable for the cupboard,
using the hole in Fig.1. When mounting align the front of
the cooker hood to the door of the cupboard and regulate
the L wall spacer through the screws marked P (Fig. 2).
The rear of the appliance must then align with the cupboard.
EXTRACTION THROUGH AN OUTSIDE WALL
The appliance expels the fumes through an outside wall or
a duct. It is necessary to buy a telescopic pipe in
accordance with the standards in use (not inflammable
with diameter 150mm) and connect it to flange F (Fig. 3).
RECIRCULATION
To transform the cooker hood from the extraction version
to the re circulating one ask your supplier for an activated
carbon filter. The activated carbon filter cleans the air of
the room. This filter is not washable or re-usable and must
be substituted at least every 4 months. Saturation of the
activated charcoal depends on how often the appliance is
used, the type of kitchen and how regularly the grease
filter is cleaned. The filter must be fitted to the extracting
group cooker hood in the centre of the fan grille by twisting
it by 90 degrees until it is gripped securely. For this
operation remove the grill G (Fig. 2). The clean air is
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für ATAG wv9011lm wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info