GB 62
16 A
installer's information
connecting up
As a specialist, you alone are competent to install and connect
up Atag appliances.
Our guarantee therefore applies only and exclusively to
appliances which have been installed and connected up by
you in accordance with the provisions of current regulations.
Failure to meet this requirement would incur the fitter's liability
and release the Atag company from any liability.
Electrical connections must be made as per the connection plate fixed
to the back of the appliance, by an electrical fitter. Who must ensure that
the appliance has been connected up in accordance with fitting instruc-
tions and local regulations.
Where the appliance is not connected to the mains electricity supply by
a plug, an omni polar cutout device (with a contacts gap of at least 3
mm) must be fitted on the supply side of the connection to meet safe-
ty requirements.
NOTE: When power is connected, the electronics of the oven are initia-
lised; this neutralizes the lighting for a few seconds.
If the oven is connected to the power supply by a plug, this must
remain accessible once the oven has been fitted.
We cannot accept any liability in the event of an accident resulting
from non-existent or faulty earthing.
If the power supply cable is damaged, it presents a potential hazard. It
must be replaced by the manufacturer, its after-sales service or a
qualified electrician.
installer's information
technical details
Operating voltage....................................................220-240 V ~ 50 Hz
Nominal power of grill........................................................2,925 kW
Total power used in cooking...................................................2,65 kW
Energy consumption
- while heating to175°C......................................................0,205 kWh
- to maintain175°C for 1 hour..............................................0,410 kWh
Total....................................................................................0,615 kWh
Inside dimensions of oven
Width................................................................................ .......43 cm
Height.......................................................................................19 cm
Depth........................................................................................38 cm
Effective volume....................................................................32 litres
network voltage connection
fuse
min.
diameter of cable
220-240V~50Hz
1 Ph + N
1,5 mm²