Before starting up
Did you transport the air dehumidifier in horizontal position or
at an angle large than 45°?
L Allow the device to stand in vertical position for at least
one hour.
L Notes
1. The air dehumidifier will not work if the set humidity value
is higher than that of the environment.
2. Only use the air dehumidifier at a room temperature
between 5 °C and 32 °C. The air dehumidifier will not
function out of this range.
3. Do not operate the air dehumidifier in heavily dust-laden
or chloric atmospheres.
4. Once the compressor has been started the fan motor and
the compressor must run for at least 3 minutes during
dehumidification. To prevent damages to the compressor,
you should wait for 3 minutes after a shut-down of the air
dehumidifier before you restart the device.
5. If the room temperature is under 10 °C and the relative
humidity of the ambient air is rather low an operation of
the air dehumidifier will not be necessary.
6. The device’s air dehumidification performance depends on
room design, room temperature and relative humidity of
the room air.
7. Drain the container when it is full. Then, reinsert the empty
water container so that the device can work again.
8. Tranport this device only in upright (vertical) position.
9. If the device does not work or if the operation is suddenly
interrupted for unknown reasons, ¨ see “Possible faults“.
10. When the air dehumidifier is in operation the compressor
generates waste heat and the room temperature slightly
increases. This is considered a normal process.
Control panel
1 ¨ ON/OFF button
2 ¨ Relative humidity (in %) or fault display
3 ¨ “Increase RH” button
4 ¨ Operating hour counter
5 ¨ “Reduce RH” button
6 ¨ Defrosting icon
7 ¨ “Fan ON” icon
8 ¨ “Water container full” icon
9 ¨ “Dehumidification mode” icon
Continuous display = dehumidfication is running
(compressor and fan on)
Flashing display = dehumidification is not
running (compressor off -
fan on)
Fault code
If the fault codes E3 – E4 – E5 are indicated in the “RH
display” ¨ see “Possible faults”.
Start-up
L An acoustic signal will sound if you connect the power
cable to an electrical socket.
A fault has occurred when this acoustic signal does not
sound. Check the power supply cable, the electrical
socket and the fuse.
Powering up
Press the button to switch on the power to the air
dehumidifier.
The display 2 ¨ “RH of air” indicates the factory-set humidity
of air of 60 %. After 5 seconds the display indicates the actual
humidity of air.
The “RH” display indicates the humidity of air in a range
between 30 % and 90 %.
Shutting down
Press the button again to switch off the power to the air
dehumidifier.
Setting the humidity value
Press the button (Increase the RH setting) or
(Reduce the RH setting) to set your desired relative humidity
of air.
If the set RH value is lower than 30 %, the device will
continuously dehumidify and the indicator 2 displays “CO”.
Hint: Normally, a relative humidity of air between 50 %
and 60 % is sufficient to have a convenient indoor
climate and to prevent condensation on structural
components and furnishing.
L If your desired RH value is lower than the actual RH by
3 %, the air dehumidifier will automatically start
(compressor). The
icon (dehumidification) is
continuously displayed.
If your desired RH value exceeds the actual RH by 3 %,
the air dehumidifier will automatically shut down
(compressor). The
icon (dehumidification) is flashing.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

atika-ale-500

Suche zurücksetzen

  • Mein Atika 500 Luftentfeuchter - der Ventilator läuft die Anzeige zeigt keine Störung an der Kompressor wird sehr heiß und es kommt kein Wasser raus. Was ist da defekt.Das Hygrostat ist auf 32% eingestellt die Umluft hat 56%.
    Wie wo kann ich den KD erreichen. Eingereicht am 29-9-2020 09:00

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Atika ALE 500 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info