ELECTRICALCONNECTION(SEE THE TABLE OF DIAGRAMS PAGE AND REFER TO THERELEVANTDIAGRAMS)
The water heater can be connected and powered only by a single-phase 220/240V AC or a three-phase 400V mains supply according to model. Connectthe water heater via a
fixedduct with a crosssection of 2.5 mm
2
.For that,use standard channeling (fixed or fluted conduit) to the calibrated receptacle in the cover. For appliances supplied with a
cable or a plug (prohibited in France),connectdirectly. The earthwire of the cable must be connectedto earth or lead the earthwire tothe terminal providedindicatedbythe
symbol :
This connection is absolutely necessary for safetyreasons.Thegreen/yellowearthleadmustbe longer thanthe two live wires. Installation mustinclude upstream of the
appliance, anall-pole cut-out device (contact opening atleast 3mm:fuse, breaker switch). Where the water pipes are are made of insulating material, the electrical contacts must
be protectedby a30mA earth-leakagebreaker conformingto the standards in force.Adapt the connection to the power supply. (see diagramsA1 to F2 and table p. 4)
Thermal circuit breaker:
All our mixed products are equipped with a thermostat with thermal circuit breakerwith manualresettingwhich cuts off the power supply to the water
heater in case of overheating.
Warning:If the safetytrips a) switch off the power before takingany further action, b) remove the cover, c) check theelectricalconnections, d) reset the thermal circuit
breaker.If the circuit breaker keeps tripping, replace the thermostat.Never shortcircuit the safety cut out or the thermostat. Connect the power supply onlyvia the
terminal.
ELECTRICAL CONNECTION. -Optionalkits: For the installation and electricalconnectionof the kits refer to the instructionincludedwith each package. (electrical kit,
pump kit) Whenusing atankfor asolar system take not of locallegislation.(E.g.: prohibitedinSpain)
SETUP/OPERATION
WARNING: Never switch on the water heater without water.
The secondarycircuitmust be filled.Before switching on, openthe hotwater taps, ventthepipesofair andfill the appliance.
Fill the primary circuit (circuit connected to the boiler) Open the water tap, unscrew the air venttopurge air introduced by the filingoperation. For an installation fitted
with a booster pump, switch it on for a moment or two to speed up de-gassing. Checkthat the system is full of water, either by checking the level of waterin the openheadertank,
or by opening the vent at the top of the installation.
Check the watertightness of the pipework and the door seal below the cover. In case of a leak, tighten slightly. Checkthat the water safety devices are working and fill the
drain.Switch on the appliance.After 15– 30 minutes, depending on the capacity of the appliance, water should drip from the drain hole.This phenomenon is due to
water expansion and is normal. Check the watertightness of the joints and the seal. During heating anddepending on water quality, room-sealed water heaters can produce a
boiling noise; this is normal and does not indicateany defect onthe appliance.
To avoid the development of bacteria (legionella…) ensure that a temperature of60°C is reachedevery day. The thermostat is set atthe factoryat the stop (65°C+- 5°C ).
IMPORTANT : If steam or boiling water emerges continuously from a supply tap or a drain valve,switch off the electricity to the water heater or boilerand call a professional
plumbingcontractor.
FOR ACIMODEL WITH CONNECTION OF THE CATHODIC PROTECTION
No other action is required (internal connections are already made).
A3 solid core power cable form the appliance powering your anti-corrosionprotection (ACI) system isready to be connected to thebridging terminal, with poweron 24/24
hours.
After switching on the appliance, check that the green ACI indicatorLED on the cover flashes no later than 15 minutes after the appliance is switchedon.
YOUR APPLIANCE IS IN WORKING ORDER
A) INWINTER
:Without electric kit: The domestic water is heated bythe primary circuit (thermalexchange).The aquastat diverter valve controls the starting of the booster
pump andallowsthe primaryfluid tocirculate;it canalsobe connected to the heatingsystempump.
B) IN SUMMER ORIN MID-SEASON
:If you have an electric kit,the boiler being disconnected , domestic hotwater will be produceby the electric current.
Cut the power supply linking the pumpcontrol thermostat.
Turn theswitchonthe electric panelfeeding the thermostatconnected to thepower supply.
Push the switch“Summer/Winter” found onthe electrical cover of the heat exchanger tank.
If you do not have anelectric kit, hotwater willbe produce by the primarycircuit (thermalexchange) -samefor winter.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Atlantic Solerio Optimum wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.