GB
www.atmos.cz
6 - GB
Operation Manual - GB
Layout of the instrument panel
1. Thermometer
2. Main switch 7. 6.3A fuse - T6, 3A/1500 - type H
3. Control thermostat (of the boiler) 8. Place for an electronic control unit (92x138 mm)
4. Pump thermostat 9. Automatic deashing switch
5. Safety thermostat 10. Burner switch
Description:
1. Thermometer - monitors the output temperature of the boiler water
2. Main switch - allows you to switch off the whole boiler if necessary (restart the pellet burner)
3. Control thermostat - control the operation of the pellet burner by the output temperature of the
boiler water
4. Pump thermostat - it is designed to switch the pump in the boiler circuit (set to a temperature of 70-80°C)
5. Irreversible safety thermostat - it serves as protection of the boiler from overheating in case of a
failure of the control thermostat or as an indicator of exceeding of the emergency temperature - after
exceeding of the emergency temperature it must be reset
7. Fuse (6.3 A) - protection of the electronic unit of the pellet burner
8. The place for an electronic control unit of the heating system can be fitted with any control unit that match-
es the opening (92x138 cm), e.g. ACD01. The electric harness is already prepared for its power supply.
9. Automatic deashing switch - it is used to switch off deashing for the purpose of emptying of the
auxiliary ash pan and restart of automatic deashing. By turning the switch off and on you will ac-
tivate the deashing module in such a way that it will stop emitting the warning sound and start the
automatic deashing operation.
10. Burner switch - it is used to start the burner and to stop it (initiate the burn-down process) before
cleaning of the boiler.