PC36 frequency range must be set according to the cut-off frequency chosen for HI-PASS filter it must be used with.
PC36 module is able to vary relative phase
between two ways of a multiamplified system. Its
purpose is to make the emission of a speakers
system, located in different places in car, more
homogeneous. Generally speaking, PC36
module allows you to put the HI-PASS filtered way with electronic crossover in phase with regards to the one which
is LO-PASS filtered in a bi-amplified system. It is possible to use two PC36 in a three way amplified system: one to
align tweeters with regards to midwoofers and one to align midwoofers with regards to subwoofer.
Used into VRx4 and VRx6, PC36 allows the front system phase alignment with regards to subwoofer. Applied into
VRx2 and VRx1, it permits to put all crosses of a multiamplified system in phase if it is used together with HI-PASS
sections of HL12, HL24, BH12 modules or with BAND-PASS sections of BH12.
Pre-select frequencies ranges through jumpers according
to cut-off frequencies of the HI-PASS filter it is used with.
PC36 is originally set on 40 ÷ 200 Hz.
- 7 -
VRx Control Extensions PC36
Frequencies ranges: 40Hz÷200Hz; 200Hz÷800Hz; 800Hz÷4,5kHz
Phase range: 0°÷360°
360˚ phase controller
Controls panel
Functions diagram
YH - Phase adjustment.
YB - Switch: PC36 ACTIVE (ON)/BYPASS (OFF).
Controls description
Short guide
Freq. range 40Hz÷200Hz
Freq. range 200Hz÷800Hz
Freq. range 800Hz÷4.5kHz
Analogue phase controller acting on the higher
frequencies of a multiamplified audio chain.
WARNING
The use of PC36 into VRx1 and VRx2 depends
on the installation of HL12, BH12, HL24
multichannel extensions, since PC36 acts only
on HI-PASS section.
Where PC36 acts:
VRx6.420
Technical features
POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 ÷ 15 VDC
IDLING CURRENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.6 A
IDLING CURRENT WHEN OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .< 0.04 mA
CONTINUOUS NOMINAL POWER Tol.: (+10%/-5%); 0.3% THD; 12 VDC
A,B,C stereo ch. on 4 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2x65W + 2x65W + 2x80 (RMS)
CONTINUOUS POWER 6 CHANNELS Tol.: (+10%/-5%); 1% THD; 12.6 VDC
A,B,C stereo ch. on 4 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2x75W + 2x75W + 2x85 (RMS)
CONTINUOUS POWER 6 CHANNELS Tol.: (+10%/-5%); 1% THD; 13.8 VDC
1) A,B,C stereo ch. on 4 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . .2x75W + 2x75W + 2x85 (RMS)
2) A,B,C stereo ch. on 2 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . . .2x120W + 2x120W + 2x150 (RMS)
3) A,B stereo ch. on 4 Ohms, C stereo ch. on 2 Ohms . . . . . . . . . . .2x75W + 2x75W + 2x165 (RMS)
4) A,B stereo ch. on 4 Ohms, C stereo ch. on 1 Ohm . . . . . . . . . . . .2x75W + 2x75W + 2x250 (RMS)
CONTINUOUS POWER 5 CHANNELS Tol.: (+10%/-5%); 1% THD; 13.8 VDC
5) A,B stereo ch. on 4 Ohms, C bridged ch. on 4 Ohms . . . . . . . . . .2x75W + 2x75W + 1x330 (RMS)
6) A,B, stereo ch. on 4 Ohms, C bridged ch. on 2 Ohms . . . . . . . . .2x75W + 2x75W + 1x500 (RMS)
7) A,B stereo ch. on 2 Ohms, C bridged ch. on 2 Ohms . . . . . . . . .2x110W + 2x110W + 1x430 (RMS)
CONTINUOUS POWER 3 CHANNELS Tol.: (+10%/-5%); 1% THD; 13.8 VDC
8) A,B,C bridged ch.on 4 Ohms . . . . . . . . . . . . . . . . . . . . . . . . . . .1x240W + 1x240W + 1x300 (RMS)
9) A,B bridged ch. on 4 Ohms, C bridged ch. on 2 Ohms . . . . . . . . .1x220W + 1x220W + 1x430 (RMS)
THD DISTORTION (1 kHz; 90% Nominal Power) . . . . . . . . . . . . . . . . . . . . . .0.02%
IMD DISTORTION (90% Nominal Power) . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.04%
BANDWIDTH (-3dB; Nominal Power) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Hz ÷ 70 kHz
S/N RATIO (A weighed - 1 VRMS input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 dBA
REMOTE IN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 ÷ 15 VDC
REMOTE OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 VDC - 150 mA
INPUT SENSITIVITY (high) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.15 ÷ 1.5 VRMS
INPUT SENSITIVITY (low) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.50 ÷ 5.0 VRMS
INPUT IMPEDANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 kOhms
LOAD IMPEDANCE (stereo) ch.A and ch.B . . . . . . . . . . . . . . . . . . . . . . . . . . .8 - 4 - 2 Ohms
LOAD IMPEDANCE (bridged) ch.A and ch.B . . . . . . . . . . . . . . . . . . . . . . . . .8 - 4 Ohms
LOAD IMPEDANCE (stereo) ch.C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 - 4 - 2 -1 Ohm
LOAD IMPEDANCE (bridged) ch.C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 - 4 - 2 Ohms
SIZE (W x H x D) mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240 x 64 x 585
SIZE (W x H x D) inches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9.4 x 2.5 x 23
INTERNAL FUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80A
ABSORBED CURRENT AT MAXIMUM MUSICAL POWER - EXTERNAL FUSE CHOICE
13.8V - configuration 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33A
13.8V - configurations 2) and 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64A
13.8V - configurations 3) and 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47A
13.8V - configurations 4) and 6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66A
13.8V - configurations 7) and 9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80A
Measures were realised through a test-set consisting of Rohde & Schwarz UPD audio analyser, HP 6453A power supply
(200A continuous) and 14F capacitive booster made with audison cable Superfarad capacitors.
Please always choose a fuse of equal or slightly higher value (max 10%) than indicated.
Note:
The use of MAC2 cooling system is strongly recommended when the amplifier is employed at full power with 1 Ohm
stereo or 2 Ohm bridged loads.
- 62 -