800553
26
Zoom out
Zoom in
Vorherige Seite
1/30
Nächste Seite
EKL
26
Type
Tubular heating
element Reconnectable heating output in kW
kW ~230V 3N~400V 3N~400V
r3 r1 r2 16 hrs. 8 hrs. 6 hrs.
4
hrs.
3 1/3
hrs. 4 hrs.
3 1/3
hrs. 3 1/3 hrs.
EKL 080 0,85 0,30 0,85 0,85 1,15 1,70 2,00 2,00
EKL 100 1,10 0,65 1,10 1,10 1,75 2,20 2,85 2,80 2,85
EKL 120 1,35 0,65 1,35 1,35 2,00 2,70 3,35 3,20 3,35
EKL 150 1,65 0,65 1,65 1,65 2,30 3,30 3,70 3,95
FIRST COMMISSIONING
The tank must be lled with water before switching on the electricity.
The expansion water created in the internal boiler during the heating process must drip from the safety valve.
Caution: The rst heating process must be implemented and monitored by a licensed expert.
The hot water drain pipe as well as parts of the safety tting may become hot.
The preset temperature and the actual temperature of the water withdrawn should correspond approxi-
mately after completed heating.
DECOMMISSIONING, EMPTYING
If a water heater is taken out of operation or unused for a longer period of time, it must be emptied and
disconnected all-pole from the electric power grid. Turn o the lead switch or the automatic cutout.
In rooms with a permanent risk of frost, the water heater must be emptied before the start of the cold sea-
son, insofar as the device remains out of operation for several days and is not operated in the anti-frost
position.
The service water is emptied through the drain valve of the safety valve combination after closing the
shuto valve in the cold water supply line and under simultaneous opening of all hot water valves of the
connected service ttings. Emptying may also be performed through the safety valve into the expansion
water funnel (drop collector). For this purpose, the small safety valve wheel is turned to the »Test« position.
Caution: hot water may exit during emptying.
In the case of a risk of frost, it must be observed also that not only the water in the water heater and in the
hot water lines can freeze, but also in all cold water supply lines to the service ttings and to the device
itself. Therefore, it is advisable to empty all ttings and lines holding water back to the frost-safe part of
the domestic water system (domestic water supply).
If the storage tank is put back into operation, then it must bindingly be observed that it is lled with water
and water exits bubble-free at the hot water valves.
INSPECTION, MAINTENANCE, SERVICE
a) During heating, the expansion water must drip visibly from the drain of the safety valve. The expansion water
quantity is approx. 3.5% of the tank’s rated volume when fully heated (approx. 80 °C).
The function of the safety valve must be checked regularly. The water must ow freely from the safety valve
unit into the drain funnel when the safety valve test knob is lifted or turned to the Test position.
Caution: the cold water supply and parts of the storage tank connector ttings may become hot thereby.
If the water heater is not heated up or hot water is withdrawn, no water must drip from the safety valve. If this
is the case, then either the water line pressure is too high (install pressure reducing valve over 5.5 bar) or the
safety valve defect. Please call a plumbing expert immediately!
b) The boiler scale as well as the furring forming in the internal boiler of the tank must be removed by an expert
after one to two years of operation in the case of heavily calciferous water.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Austria Email EKL serie wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info