14. INSPECTION, MAINTENANCE, CARE
a) During the heat-up phase the expansion water must drip noticeably from the safety valve drain. When fully heated
(~ 80° C) the expansion water makes up approximately 3.5% of the rated capacity of the water heater.
Regularly check for proper function of the safety valve. When lifting or turning the safety valve test knob to the “Test”
position, the water must ow unhindered from the safety valve body into the funnel.
Caution: The cold water inlet and parts of the water heater tting can get hot during this process. If the tank is not hea-
ted up or hot water removed, no water is allowed to drip from the safety valve. If this is the case, either the water line
pressure is greater than the permitted value (in Switzerland more than 6 bar) or the safety valve is defective. If the water
line pressure is greater than permitted (6 bar in Switzerland), a pressure reducing valve must be used.
b) If the service water has a high lime content, removal of the scale formed in the interior boiler as well as of the free lime
particles must be performed by a technician every one to two operating years. Cleaning is done through the ange
opening – remove heater ange, clean tank, and use a new gasket when reassembling the ange. The screws must be
tightened in a cross pattern with a tightening torque of 18 Nm - 22 Nm. The special enamelled inner container of the
water heater must never come into contact with scale solvent. Do not work with the decalcication pump! Then ush
the unit thoroughly and perform the heat-up cycle as for initial startup of the unit.
c) To make a proper warranty claim as provided for by AE-AG, the installed sacricial anode must have been inspected and
this inspection documented by a technician at intervals of no more than 2 operating years. During maintenance works,
it is advisable to open the cleaning and service ange in order to check the tank for any possible washing-in of foreign
objects and contaminations, and to remove these if necessary.
The external current anode has a virtually unlimited life expectancy. Its function must be regularly checked by noting the
inspection lamp. This indicates two conditions:
green: System OK.
ashing red: Fault: Contact customer service!
The prerequisite for proper function is that the container is lled with water. Conductivity of at least 150 μs is required to
ensure that the external current anode functions properly.
d) The area in which the unit is operated must be kept from freezing. The unit must be installed in a location where it can
be easily accessed for maintenance, repair and possible replacement. When water with high lime content is used, we
recommend installing a commercially available water softener, since the natural calcium formation is not a basis for any
claims under the terms of the AE-AG warranty. For proper operation of the water heater a corresponding potable water
quality which meets national codes and laws (such as the Federal Ordinance on the Quality of Drinking Water TWV;
Federal Law Gazette II Nr. 304/2001) must be used.
32

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Austria Email HR 300 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info