800541
19
Zoom out
Zoom in
Vorherige Seite
1/72
Nächste Seite
19
Id.Nr. 235161-13
4. HEATING INSERTS
Important: All metallic components such as SH, RWT, and/or EBH are to be inserted electrically insulated from the tank. To
protect the built-in parts from corrosion, a transition resistance of about 600 Ω is to be provided (if not yet installed in the
built-in parts at the factory).
Screw-in heater
Water heaters whose model name contains an „..M.., are tted with a 1 1/2“ sleeve which can be used to install an electric
screw-in heater for supplementary or auxiliary heating. Screw-in heaters are designed technically as supplementary heating,
and should not be used for continuous heating (failure due to natural calcication is not a sucient reason for claim). It is also
important to ensure that when an SH heater is used in enamelled hot water tanks, an insulated design is available opposite
the tank (see RWT).
Ribbed tube heat exchanger
All metallic insert (ush mounted) components having a larger metallic surface area (e.g., condenser insert heat pumps,
ribbed tube heat exchangers, electric heaters) must be electrically isolated from the water heater. In order to protect these
insert (ush mounted) components against current-induced corrosion, we recommend installing a dened contact resis-
tance of approx. 600 Ω (unless already installed in the components ex works). The water heaters may not be transported with
the ribbed tube heat exchanger installed. Installation must be performed on-site. Attention must be paid to full overlapping
of screw threads on all coupling sleeves. When installing a ribbed tube heat exchanger, make sure that the storage tank is still
protected against corrosion.
Therefore, an appropriate external current anode or magnesium reactive anode must be mounted when the magnesium
reactive anode is removed from the storage tank with the ange plate during assembly of a ribbed tube heat exchanger.
Electric built-in heater
Appliances with electrically powered built-in heaters are equipped with a safety temperature limiter which turns o further
heating of the appliance at a temperature of max. 110 °C (EN 60335-2-21; ÖVE-EW41, Part 2 (500)/1971). Therefore, select the
connection components (pipe ttings, circulation, safety valve combination, etc.) such that they will resist temperatures of
110 °C in the event of any possible malfunction of the thermostat and thus preventing consequential damage.
Assembly and installation may be performed only by authorized specialists.
A built-in heater, installed via the ange, is provided for continuous operation.
The built-in or screw-in heaters must be installed or designed with insulation (at least 600 Ω), as otherwise the tank interior
may corrode.
If the corrosion protection is built-in to the ange plate as standard, alternative corrosion protection must be provided if the
ange plate is removed.
Due to the hysteresis of the thermostat (±7 K) and potential dissipation losses (cooling of the pipelines) the temperatures can
deviate by ±10 K.
If the water heater is heated via its heat exchanger, ensure that the hot water temperature cannot exceed 85 °C under any
circumstances, as it could trigger the safety temperature limiter of the electric heater, and shut the heater down.
5. FLANGE INSERTION OPENING
Depending on the system design, electric built-in heaters or heat exchangers
can be installed on the boiler ange Ø240 mm (clear diameter Ø173 mm,
hole circle Ø210 mm, 12 x M12) and Ø180 (clear diameter Ø117 mm, hole
circle Ø150 mm, 8 x M12).
Built-in electric heating elements are to be installed so that the thermostat
probe is at the top.
The screws must be tightened in a cross pattern with a tightening torque of
23 Nm - 25 Nm.
Flange ring
Gasket
Spacer
Range plate
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Austria Email KDU 102 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info