english 5 G3
Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the
entire unit
, before the heating unit is installed.
Combustion air
Being the user of the stove you must take care of a
sufficient combustion air supply. Sealed-up windows
and doors may not allow a sufficient combustion air
supply or disturb the draught behaviour of your stove.
Please ensure the additional supply of fresh
combustion air if necessary. For details please
consult your specialist retailer.
Stove pipe connection
For your own safety stringent laws apply for
connecting the stove pipes to the chimney. Your
professional dealer or distributor knows these laws.
Please have your certified retailer carry out the
connection of your stove.
3. CORRECT OPERATION OF YOUR STOVE
Approved fuels
Dry, well cured and natural wood (hardwood
preferred), wood briquettes.
Maximum amount of fuel
Maximum amount of fuel to be added: 1,6 kg wood
or appr. 1,8 kg wood briquettes. Larger amounts of
fuel can lead to overheating and thus damage the
stove.
Clean burning
The wood must be dry (relative wood moisture
< 15%) and untreated. The right amount of wood
must be burned in order to ensure a clean fire that
releases only small amounts of emission
s.
Making a fire
Prepare everything you need for starting the firesoft
wood chips, igniter materials (such as Austroflamm
lighter), wood. Figure 1 provides a good overview of
the quantity of the materials you will need.
Open the air all the way. See figure 2.
Open the stove door.
Put ignition aid on the floor of the firebox.
Lay soft wood chips onto the paper.
Lay one or two logs of wood on the wood chips.
Figure 3: Igniting the Fire
Light the ignition aid. Close the firebox door.
.
Figure 4: Close the Primary Air
As soon as the wood logs are burning well, you
can regulate the heating capacity with the air
slider. (slider set to the maximum (“AUF”) setting
produces maximum heat – see figure 2.)
When adding wood to the fire, follow the same
procedure as when igniting the fire: Open
secondary air, carefully open firebox door, lay
wood on the fire, close the firebox door.
Wait until the added wood catches fire and is
burning. Subsequently regulate the fire with the
secondary air supply.
Heating in between seasons
Heating the stove in between seasons, when the
outside temperatures are higher, the flue gases may
not be able to escape completely and this may lead to
disturbances in the chimney draught, especially if the
temperatures are rising suddenly. The stove has to
be charged with less wood and the primary air has to
be increased so that the wood can burn down faster
(with visible flames) and thus the chimney flue can
stabilize.
symbol figures
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

austroflamm-gussofen-g3

Suche zurücksetzen

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Austroflamm Gussofen G3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info