1. TECHNICAL DATA
As a stove of construction type 1, it is possible to
connect it to the flue pipe of an existing other stove
or another furnace for solid and liquid fuels, as
long as the chimney does complies with DIN 4705,
Part 3.
TECHNICAL DATA
Hei
g
ht 1815 mm
Width 980 mm
De
th 817 mm
Wei
g
ht 344 k
g
Wei
g
ht with ceramic shell 391 k
g
Flue
p
i
p
e outlet diameter 180 mm
Nominal thermal out
p
ut
(
DIN 18891
)
9 kW
Maximum thermal ca
p
acit
y
13 kW
Smallest heating capacity
4,5 kW
Room heating capacity (depending
on building insulation)
100 – 200
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
accordance with DIN 4705, Part 2
Fluegas mass flow closed 11 g/s
Fluegas temperature closed 280 °C
Minimum feed pressure
Nominal thermal output
closed 0.12 mbar
at 0.8 times
n. ther. outp.
0.09 mbar
2. IMPORTANT INFORMATION
The installation and operation information given
here is of a general nature, exact regulations may
vary from country to country. The rules in force in
your country should always take precedence.
General Safety Instructions for
the Operation of Your Stove
Thoroughly read the entire manual before
starting up your stove and ensure compliance with
the warnings.
Your heating unit may not be moved without
approved means of transport with sufficient load-
bearing capacity.
Your heating unit is not suitable to be used as
a stand or as a ladder.
The burning of fuel releases thermal energy
that leads to a substantial heating up of the surface
of the heating unit, the doors, the parts mounted
on the door, door glass, flue pipe and in some
cases the front wall of the heating unit. Do not
touch any of these surfaces without respective
protective clothing or without the help of
accessories such as heat-resistant gloves or a cold
hand.
Make your children aware of this particular
danger and keep them at a distance from the
heating unit whenever it is in operation.
Only burn approved fuels and materials listed
in the section entitled Clean Burning.
The burning or introduction of flammable or
explosive materials, such as empty spray cans and
the like into the firebox as well as the storage of
such materials in the immediate vicinity of your
heating unit is strictly forbidden due the danger of
explosion.
Do not wear loose or flammable clothing when
adding fuel to the fire.
Placing non-heat-resistant objects on the
heating unit or in the vicinity of the heating unit is
forbidden.
Do not lay laundry onto the stove for drying.
Laundry hung up to dry must be kept at a safe
distance from the stove because of the danger of
fire.
When operating your heating unit it is
forbidden to use flammable or explosive materials
in the same or an adjacent room to the one in
which your heating unit is located.
Setting Up Your Stove
Safety Clearances (Minimum Distances in
Fig. 2)
3. To nonflammable objects:
a > 400 mm b > 200 mm
4. To flammable objects and to supporting walls of
reinforced-concrete construction with
convection shell:
a > 800 mm b > 200 mm
(a – toward the front in the radiated area)
(b – to the side and to the back)
Make sure that the room in which the stove is set
up has at least one door or window to the outside
or is directly adjacent to such a room.
Subject to technical and optical modifications. Formatting and printing errors excepted.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Austroflamm IRONY XL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info