english 5 Yan Xtra / Ray Xtra
1. TECHNICAL DATA
As a stove of construction type 1, it is possible to connect it
to the chimney together with an existing other stove or
another hearth for solid fuels, as long as the chimney
calculation complies with DIN 4705, Part 3.
TECHNICAL DATA
Yan
Ray
Height
1480 mm
1368 mm
Width
490 mm
634 mm
Depth
400 mm
472 mm
Weight
263 kg
327 kg
Weight HMS
115 kg
115 kg
Flue pipe outlet diameter
150 mm
150 mm
Nominal thermal output
7 kW
7 kW
Max. thermal capacity
9 kW
9 kW
Smallest heating capacity
3,5 kW
3,5 kW
Room heating capacity (depending on
building insulation)
82210 m³
2. IMPORTANT INFORMATION
The installation and operation information given here is of
general nature. National and European standards, local and
building regulations as well as fire prevention laws must be
observed during the operation of the stove.
General safety instructions for the
operation of your stove
Read the entire manual before starting up your stove
thoroughly and observe the caution notices.
Your heating unit must not be moved without approved
means of transport with sufficient load-bearing capacity.
Your heating unit is not suitable to be used as a stand or
as a ladder.
Please keep in mind that your
stove’s surface heats up considerably
during operation. We therefore
recommend wearing a safety mitten
when operating your stove.
Attention stove varnish is no rust prevention!
Make your children aware of this particular danger and
keep them at a distance from the heating unit whenever it is
in operation.
Only burn approved fuels and materials as listed in the
chapter “Clean Burning”.
The burning or placing of flammable or explosive
materials, such as empty spray cans, etc. into the firebox as
well as the storage of such materials in the immediate
vicinity of your heating unit is strictly forbidden due to the
danger of explosion.
Do not wear loose or flammable clothing when adding
fuel to the fire.
Placing non-heat-resistant objects on the heating unit or
in the vicinity of the heating unit is forbidden.
Do not lay laundry onto the stove for drying. Laundry
hung up to dry must be kept at a safe distance from the
stove because of the danger of fire.
The wood stove is not suitable for long term heating.
During the operation of your heating unit it is forbidden to
use flammable or explosive materials in the same or an
adjacent room to the one in which your heating unit is
located.
The appliance must be operated with the stove door
closed.
The stove door and all fittings for adjusting the stove
must be closed, if the appliance is out of use.
Setting up your stove
Required safety distances (Minimum distances
see name plate - in Fig. 2)
a > 800 mm - towards the front in the radiated area
b > 100 mm to the side
c > 110 mm to the back
Make sure that the room in which the stove is set up has at
least one door or window into the outside or is directly
adjacent to such a room. Other fireplaces and extractor
hoods must not be operated in the same room as the stove.
Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the entire
unit, before the heating unit is installed.
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the calculation of
the chimney measurements in accordance with DIN 4705,
Part 2
Fluegas mass flow
closed
5,4 g/s
Fluegas temperature
closed
340 °C
Minimum feed pressure
Nominal thermal output
closed
12 Pa
at 0.8 times n.
ther. outp.
10 Pa
Subject to technical and optical modifications. Formatting and printing errors excepted.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Austroflamm Ray Xtra wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info