Note: During the operation of the sand lter
pump, check the pressure reading of the
manometer.
Generally, when the pressure of the
recommended sand lter pump is less than
0.2bar (3psi) (green area) , it runs normally.
Note: You must make sure that maintenance
begins only after the sand filter pump is
unplugged. Otherwise serious risks such as
personal injury and even death may occur.
Note: Record the reading of the manometer
during the operation of the sand lt er pump.
When the manometer shows a pressure
of 0.2bar (3psi) or higher, please clean up
the sand bend or replace the sand. Use
"backwash" and "rinse" functions.
Note: regular rinsing according to use
situation is recommended.
Long-term storage and storage in winter
Using the product in a frozen pool may damage the product and invalidate the
quality warranty. If the product has to be used with antifreeze, propylene glycol
may also be used. Propylene glycol is a nontoxic chemical unharmful to any plastic
parts. Other types of antifreeze are highly toxic and may be harmful to the product’s
plastic elements.
1.Before discharging the water or repostioning of the pool, make sure the discharge
direction is towards the discharging ditch and away from the home. Review local
regulations for special water treatment requirements.
2.Switch off the product and remove the power plug.
3.After emptying, remove all connected sand filter pumps, corrugated tubes and
lter hoods on the pool wall.
4.Unscrew the drain valve (8) in an anticlockwise direction to completely empty
water inside the body. The drain plug is at the bottom of the body.
5.Dry the parts of the sand lter pump and corrugated tubes.
6.Lubricate the seal rings and washers in the order below for long-term storage.
7.The best practice for product storage is to dry the parts and motor and replace
them in the original package. To avoid shrinkage or corrosion, do not cover or wrap
the motor with a plastic bag.
8.Please store the motor and parts in a dry place at 32°F (0°C) ~104°F (40°C).
Diagnosis of Problems and Solutions
Problems Checking Solutions
The motor can not be
started normally
Power plug not properly
inserted
Leakage protection
disconnected
Motor overheated or
overloaded
Causes motor to stop
Make sure the power cord is inserted
into the 3-core grounded metal
receptacle.
Reset circuit breaker. If the problem
persists, the power system may be
defective. Power off immediately and
confer with an expert.
Allow the motor to cool naturally and
start it again.
Filter
Unable to rinse the pool
No sand in the body
Location error of the control
valve
Excessive dirt in water
Filter barrel blocked
Sand filling Refer to sand filling
instructions
The control valve rotates to the filter
position
to prolong the running time
Clean the lter barrel
The filter is unable to
discharge water or the water
ow rate is too slow
There is blockage at the
inlet
There is an air leakage at
the gap of the inlet
Excessive dirt in water
Filter medium is blocked by
impurities
The pool is connected with
a cleaning device
Check and clear away the blockage in
the water pipes
Tighten the nozzle nuts and check the
damaged point of the nozzle and water
height
Clean the lter screen
Backwash
Disassemble the cleaning device
connected to the pool
Filter fails to run Water level is too low
Filter screen is blocked
Air leakage from the inlet
pipe
Motor or blade is blocked
Inject water to adjust water level
Clean the lter screen in the pool
Tighten the nozzle and check the
damaged point
Replace the ttings
Water leakage on the control
valve or upper cover
The seal ring of the body is
lost or too dirty
The control valve retainer
is not tightly secured
ordamaged
Remove the upper cover of the control
valve and sleeve the seal ring of the
body
Clean the seal ring of the body with a
water pipe
Tighten the screw with a screwdriver
Replace the ttings
The manometer fails to run The inner wall of the
manometer is blocked
The manometer is damaged
Remove the manometer from the
control valve and clear away the
impurities on the inner wall
Replace the ttings
Sand enters the pool The sand particles are too
ne
Use 20# quartz sand only
Particle size of the sand is 0.45-0.85mm
Or replace the sand
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Avenli 290732 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Avenli 290732

Avenli 290732 Bedienungsanleitung - Englisch, Italienisch, Portugiesisch, Spanisch, Polnisch - 23 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info