5. Keyboard manipulation
Note: Keys "AUX1", "AUX2", "F3", "F4", "MON ", "ACK " and "MSK " are invalid and will not be used. Use the "SAL"
key to clear your input.
1. How to choose a camera:
• Press "-1" to choose the previous camera.
• Press "+1" to choose the next camera.
• To choose a specific camera, press a camera number from 1-99 and then press "CAM".
2. Pan/tilt and lens control:
• Input a camera number from 1-99 and press "CAM". You can also choose a camera by pressing
"-1" (previous camera) or "+1" (next camera).
• Press "I+" or "I-" to open or close the iris, press "Z+" or "Z-" to zoom in or out, press "F+" or "F-"
to focus in or out. You can also use the keyboard joystick.
• Press "PAN" for a continuous horizontal rotation. Press "PAN" to stop or to start again
(depending on the type of camera).
3. How to preset positions (depending on the dome camera type):
• Move the joystick and adjust to the desired location.
• Press "F1" and then press "8".
• Input the preset number (1-64).
• Press "PRE".
4. How to view the preset positions:
a) Manually:
• Choose a camera by pressing a camera input number.
• Input the pre-position number (1-64).
• Press "CALL" to view the pre-set position and to stop.
b) Automatically:
• Choose a camera by pressing a camera input number (2-16). The maximum transfer length is
16.
• Input the number of pre-positions you want to view sequentially (2-16).
• Press "RUN".
c) Stop the auto-touring:
• Choose the scanning camera.
• Press "HOLD". The camera will stop scanning and the other cameras will continue working
normally.
5. Decoder switch control:
"AUX1" and "AUX2" are invalid.
6. There are two methods to set the delay time:
• Press "DWL" to add 1 unit at a time. The delay time ranges from 1 to 60 sec.
• Input the desired delay time (with a minimum of 4) and press "DWL".
7. Press "SAL" to reset the number previously keyed in.
8. Address:
Standard address is on PELCO-P protocol.
Example: Camera 1 on 1
st
address (OFF, OFF, OFF, OFF, OFF, OFF)
Camera 2 on 2
nd
address (ON, OFF, OFF, OFF, OFF, OFF)
Camera 3 on 3
rd
address (OFF, ON, OFF, OFF, OFF, OFF)
Camera 4 on 4
th
address (ON, ON, OFF, OFF, OFF, OFF)
Etc.
Last camera: Jumper K4 on PCB OFF