Preparation manual
Gas Fire Front 70-75 PF2
---- Floating Frame --------------- Floating Frame + ----
---- Hidden Door --------------------- Hidden Door + ----
Serial number:
Production date:
© Barbas Bellfires BV
This document or parts thereof may not be reproduced, stored in a retrieval system, ortransmitted,
in any form or by any means, electronic, mechanical, photocopying,recording, nor otherwise,
without the prior written permission of Barbas Bellfires BV.This document could contain technical
inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document
from time to time in thecontents thereof.
Contact information
Barbas Bellfires BV
Hallenstraat 17, 5531 AB Bladel, The Netherlands
Phone: +31 49 733 9200
E-mail: info@barbas.com
Introduction
2Gas Fire Front 70-75
Contents
1 About this document................................................................................ 4
1.1 How to work with this document.................................................................................................. 4
1.2 Warnings and cautions used in this document............................................................................ 4
1.3 Related documentation................................................................................................................4
2 Overview of the concentric flue system................................................... 5
3 Safety.......................................................................................................6
3.1 Safety instructions for installation................................................................................................ 6
4 Requirements...........................................................................................7
4.1 Requirements on the location...................................................................................................... 7
4.2 Requirements on the convection package (option)......................................................................7
4.3 Other requirements......................................................................................................................7
4.4 Requirements on the roof and wall outlet.................................................................................... 8
4.5 Requirements on the concentric flue system.............................................................................10
4.5.1 Possibilities for a concentric flue system with a roof outlet............................................. 11
4.5.2 Possibilities for a concentric flue system with a wall outlet............................................. 17
5 Technical specification...........................................................................22
5.1 Gas Fire Front 70-75 PF2 with Floating Frame......................................................................... 22
5.2 Gas Fire Front 70-75 PF2 with Floating Frame +...................................................................... 23
5.3 Gas Fire Front 70-75 PF2 with Floating Frame and adjustable legs......................................... 24
5.4 Gas Fire Front 70-75 PF2 with Floating Frame + and convection casing..................................25
5.5 Gas Fire Front 70-75 PF2 with Hidden Door............................................................................. 26
5.6 Gas Fire Front 70-75 PF2 with Hidden Door +.......................................................................... 27
5.7 Gas Fire Front 70-75 PF2 with Hidden Door and adjustable legs............................................. 28
5.8 Gas Fire Front 70-75 PF2 with Hidden Door and convection casing.........................................29
5.9 Dimensions of the restriction plate.............................................................................................30
6 Available components for the concentric flue system - natural
draught........................................................................................................31
6.1 Appliance part list.......................................................................................................................31
6.2 Bellfires - Muelink & Grol system Ø100 - Ø150......................................................................... 32
6.3 Bellfires - Muelink & Grol system Ø130 - Ø200......................................................................... 38
6.4 Poujoulat - DUOGAS system Ø100 - Ø150...............................................................................42
6.5 Poujoulat - DUOGAS system Ø130 - Ø200...............................................................................45
6.6 Ontop - Metaloterm US system Ø100 - Ø150............................................................................47
6.7 Ontop - Metaloterm US system Ø130 - Ø200............................................................................51
6.8 Jeremias/STB - H-Twin system Ø100 - Ø150............................................................................56
6.9 Jeremias/STB - H-Twin system Ø130 - Ø200............................................................................60
6.10 Jeremias - TWIN-GAS system Ø100 - Ø150.............................................................................63
6.11 Jeremias - TWIN-GAS system Ø130 - Ø200.............................................................................69
6.12 Modinox - PLA system Ø100 - Ø153......................................................................................... 75
6.13 Modinox - PLA system Ø130 - Ø200......................................................................................... 85
Contents
Gas Fire Front 70-75 3
1 About this document
This document shows the necessary information to do these tasks on the Gas Fire Front
70-75 PF2:
Preparation for installation
This document refers to the Gas Fire Front 70-75 PF2 as 'the appliance'. This document
is an essential part of your appliance.Read it carefully before you do work on the
appliance. Keep it in a safe place.
The original instructions of the document are in English. All other language versions
of the document aretranslations of the original instructions.It is not always possible to
provide a detailed illustration of every single item of theequipment. The illustrations in this
document show a typical setup. The illustrationsare for instructional use only.
1.1 How to work with this document
1. Make yourself familiar with the structure and content of the document.
2. Read the safety section in detail.
3. Make sure that you understand all theinstructions.
4. Do the procedures completely and in the given sequence.
1.2 Warnings and cautions used in this document
Warning
If you do not obey these instructions, there is a risk that can cause personal injury or
death.
Caution
If you do not obey these instructions, there is a risk of damage to the equipment or to
property.
Note
A note shows more information.
Symbol Description
Visual sign that there is a hazard
Visual sign that there is a notice
1.3 Related documentation
Preparation manual
Installation and maintenance manual
User manual
Assembly instructions for concentric flue system
About this document
4Gas Fire Front 70-75
2 Overview of the concentric flue system
The concentric flue system provides the appliance with combustion air and removes the
flue gases from the appliance. The concentric flue system is made of these items:
Item Description
Concentric flue
The concentric flue is a pipe with an inner pipe. The
inner pipe is used as flue gas channel and the space
between the inner pipe and the outer pipe is used as
combustion air channel
Flue gas channel
The flue gases from the appliance flow through the
channel to the outlet by natural draught or, with the
Opti-Vent installed, forced draught.
Combustion air channel Supplies the appliance with fresh air from the outlet
through the channel
Outlet/terminal Entry for the combustion air channel and exit for the
flue gas channel
Overview of the concentric flue system
Gas Fire Front 70-75 5
3 Safety
3.1 Safety instructions for installation
Caution:
The appliance must be installed as a 'room sealed system' appliance
by a certified and registered gas installation engineer in accordance with
the supplied installation instructions, and nationally and locally applicable
regulations.
If you have any questions regarding the installation, consult your local gas
company.
Before the installation starts, make sure that the details on the rating plate
correspond with the gas type and supply pressure as intended for the
appliance.
Only use items in the installation that are specified in this manual and the
related documents.
Only use the following brands for the installation of the concentric flue
system:
Manufacturer System Flue gas extraction
Bellfires Muelink & Grol system Natural draught
Poujoulat DUOGAS system Natural draught
Ontop Metaloterm US system Natural draught
Jeremias/STB (STB =
Schoorsteen Techniek-
Brummen NL)
H-Twin system Natural draught
Jeremias TWIN-GAS system Natural draught
Modinox PLA system Natural draught
Barbas Opti-Vent system 1Forced draught
Do not use a combination of parts from different brands for the installation
of the concentric flue system.
All concentric flue systems in this list can be installed with (prefabricated)
building materials that are suitable for T400 or higher.(T400 as described
in the standard: prEN 1856-1; Chimneys - Requirements for metal
chimneys - Part 1: System chimney products ). Concerns building
materials according to DIN 18160 Chimney systems.
1For installation and use of the Opti-Vent system refer to the Barbas manual "installation and mainte-
nance manual Opti-Vent system.
Safety
6Gas Fire Front 70-75
4 Requirements
4.1 Requirements on the location
Never use combustible building materials for the fireplace.
Do not install the appliance against a flammable rear wall.
Install a non-flammable insulation plate of at least 12 mm between the appliance and
a non-flammable rear wall. The insulation plate must cover the entire area of the rear
of the appliance.
For details about the installation, minimum clearances to flammable materials,
permitted insulation materials and air gaps, refer to the "installation and maintenance
manual".
If the fire burns in the appliance, make sure that the floor temperatures below and in
front of the appliance cannot be higher than 85 °C .
Make sure that the room where the appliance is installed is properly ventilated.
4.2 Requirements on the convection package (option)
The convection outlet opening must be at least 0,5 meter above the appliance.
No flammable material is present within 10 cm on both sides and 20 cm above the
convection outlet opening.
The convection outlet opening must be at least 15 cm below the ceiling.
4.3 Other requirements
The gas supply connection is located near the right side of the appliance for an easy
connection.
Only use gas piping of at least ½" and a shut-off valve to connect the gas supply to the
gas connection of the appliance.
Make sure that there is a wall socket with an earth connection nearby the appliance.
The socket must be accessible at all times. The power cable (+/- 0.5 m) is coming
from the right side of the appliance.
Install the fireplace on a solid floor that can bear the weight of the appliance and the
fireplace.
If the floor is made of flammable material, take correct safety measures. Install a
temperature protection plate made of nonflammable material between the appliance
and the floor.
Install the appliance as a built-in appliance in a new fireplace.
If the concentric flue system is installed in an existing chimney that is used for wood or
coal fire, clean the chimney.
If you built a new fireplace, make sure that it is ventilated with vents at the bottom and
top of the fireplace. If the fireplace is not ventilated the temperature of the appliance
can increase to dangerous temperatures and damage the fireplace.
Keep a minimum distance between the appliance and flammable mantelpieces. Refer
to the chapter "Mantelpiece clearances" in the "installation and maintenance manual":
for the correct minimum clearances.
Requirements
Gas Fire Front 70-75 7
4.4 Requirements on the roof and wall outlet
Location of roof and wall outlets
Refer to the table hereunder for explanation of the figure.
Note: All the minimum distances in the table are guidelines. Consult your
national and local regulations for the exact minimum distances.
Requirements
8Gas Fire Front 70-75
Minimum separation distances for roof and wall outlet(terminal) in mm
Location
Minimum
distance
[mm]
A Below an opening 2 on the same wall/roof 2000
B Above an opening 3 on the same wall/roof 700
C Horizontally to an opening 3 on the same wall/roof 700
D Horizontally to a facing opening 3 in a opposite wall 2000
E From a roof terminal under an opening 3 in a nearby rising wall 4000
F Above a flat or pitched roof 300
G Horizontally from a terminal on the same roof 300
H From a structure (e.g. brick chimney) on the roof 300
I Below a roof window in a pitched roof 2000
J Above a roof window in a pitched roof 600
K Horizontally to a roof window in a pitched roof 600
L From an internal or external corner 500
M From a vertical drainpipe or soil pipe 300
NBelow gutters, soil pipes or drainpipes, made of flammable materials 500
Below gutters, soil pipes or drainpipes, made of non-flammable materials 300
OBelow eaves, made of flammable material 500
Below eaves, made of non-flammable material 300
P Below balcony 3 or car port roof 2000
Q Beyond the balcony 4 edge 0
R On either side of a balcony 41500
S Above ground, roof or balcony 4 level 300
T From a surface facing the terminal 500
U From a terminal facing the terminal (at the same height) 600
V From an opening in the car port into the building 1200
W Vertically from a terminal on the same wall 1200
X Horizontally from a terminal on the same wall 300
Y From a boundary alongside the terminal 1000
Z From a boundary facing the terminal 2000
If the outlet is installed less than 0.5 m horizontally and less than 2 m vertically from a
public area, install an effective protector.
Make sure that the mesh size of the guard does not effect the operation of the
appliance.
If the height of the outlet is less than 3 meter from the floor, the distance between the
outlet and a garden or a terrace must be minimum 2 meter.
2An opening here means an element that is permanent open (example: an air vent) or that can open
(example: a door or window). But, in addition, the distance between outlet and built-in elements
(example: window, door) must be minimum 300 mm.
3Balcony or gallery of an apartment building.
Requirements
Gas Fire Front 70-75 9
4.5 Requirements on the concentric flue system
Caution:
Make sure that no flammable materials are located close to the flue
system. The outer walls of the flue system can be 150 °C.
Make sure that the concentric flue system is in a casing.
Make sure that the casing is made of heat resistant material.
Make sure that air can flow in the casing. Use grates near the floor and
near the ceiling. Do this for every floor where the casing is located.
Do not insulate the concentric flue.
The parts that are required for the installation of the concentric flue system are numbered
in the illustrations and refer to the part list in
6
.
Use the universal wall/floor support (number 36 in the part list) to attach the concentric
flue system to the casing and/or the floor.
Floor support Wall support
Install a concentric flue system as described in this section.
Some configurations of the concentric flue system require the installation of a flue
restriction plate. Different sizes of the flue restriction plate are delivered with the
appliance. Refer to the Installation and maintenance manual.
Requirements
10 Gas Fire Front 70-75
4.5.1 Possibilities for a concentric flue system with a roof outlet
Rigid concentric flue systems
Note: Refer to chapter
6
for a description of the numbers in the figures.
4,28,(100)
1
10/11/12/13
23
24
17
16
24
18
16
Y
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appli-
ance is Ø100-Ø150 mm
Concentric connection on the appli-
ance is Ø130-Ø200 mm
2.0 - 4.0 m 30 mm 65 mm
4.0 - 12.0 m 40 mm 80 mm
Requirements
Gas Fire Front 70-75 11
4,28,(100)
1
10/11/12/13
14,15
17
16
24
23
23
Y1
X
Y2
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y1
(min. - max.)
X
(min. - max.)
Y1 + Y2
(min. - max.)
Flue gas restriction plate width
Concentric connection
on the appliance is
Ø100-Ø150 mm
Concentric connection
on the appliance is
Ø130-Ø200 mm
1.0 - 11.0 m 0 - 3.0 m 2.0 - 11.0 m - 40 mm
Caution:
Make sure that Y1 + Y2 is at least 2 times larger than X.
Requirements
12 Gas Fire Front 70-75
Flexible concentric flue systems
4,28,(100)
1
30
32
29
5
7
26
29
23
25
18
10/11/12/13
Y
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appli-
ance is Ø100-Ø150 mm
Concentric connection on the appli-
ance is Ø130-Ø200 mm
2.0 - 4.0 m 30 mm 65 mm
4.0 - 12.0 m 40 mm 80 mm
Roof outlet using an flexible Ø100 mm liner in an existing lined chimney.
Requirements
Gas Fire Front 70-75 13
4,28,(100)
1
30
32
29
5
7
26
23
25
29
≥45°
18
10/11/12/13
Y3
Y1
Y2
X
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y1
(min. - max.)
X
(min. - max.)
Y1 + Y2 + Y3
(min. - max.)
Flue gas restriction plate width
Concentric connection
on the appliance is
Ø100-Ø150 mm
Concentric connection
on the appliance is
Ø130-Ø200 mm
1.0 - 11.0 m 0 - 3.0 m 2.0 - 11.0 m - 40 mm
Caution:
Make sure that Y1 + Y2 + Y3 is at least 2 times larger than X.
Roof outlet using an flexible Ø100 mm liner in an existing lined chimney.
Requirements
14 Gas Fire Front 70-75
4,28,(100)
1
31
30
32
29
6
8
7
26,29
27,28,29
18
29
Y
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appli-
ance is Ø100-Ø150 mm
Concentric connection on the appli-
ance is Ø130-Ø200 mm
2.0 - 4.0 m 30 mm 65 mm
4.0 - 12.0 m 40 mm 80 mm
Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing
unsound lined chimney.
Requirements
Gas Fire Front 70-75 15
4,28,(100)
1
30
31
32
29
6
7
8
26,29
27,28,29
≥45°
18
29
Y3
Y1
Y2
X
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y1
(min. - max.)
X
(min. - max.)
Y1 + Y2 + Y3
(min. - max.)
Flue gas restriction plate width
Concentric connection
on the appliance is
Ø100-Ø150 mm
Concentric connection
on the appliance is
Ø130-Ø200 mm
1.0 - 11.0 m 0 - 3.0 m 2.0 - 11.0 m - 40 mm
Caution:
Make sure that Y1 + Y2 + Y3 is at least 2 times larger than X.
Roof outlet using an flexible Ø100 mm liner and flexible Ø150 mm liner in an existing
unsound lined chimney.
Requirements
16 Gas Fire Front 70-75
4.5.2 Possibilities for a concentric flue system with a wall outlet
Note: Refer to chapter
6
for a description of the numbers in the figures.
Install the wall outlet in the correct position as shown in the figure. The centre of the inner
pipe must be positioned above the centre of the outer pipe.
Rigid concentric flue systems
19
1
10/11/12/13
4,28,(100)
14
Y
0.16 m
X
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y
(min. - max.)
X
(min. - max.)
Flue gas restriction plate
Concentric connection
on the appliance is
Ø100-Ø150 mm
Concentric connection on
the appliance is Ø130-
Ø200 mm
1.5 - 2.5 m 0 - 0.6 m - -
2.5 - 3.5 m 0 - 1.6 m - -
Requirements
Gas Fire Front 70-75 17
19
1
110/111/113
4,128
14
100
Y
0.16 m
X
Concentric flue connection on appliance Ø130-Ø200 mm
Y
(min. - max.)
X
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance
is Ø130-Ø200 mm
0.5 - 1.0 m 0 - 0.6 m -
1.0 - 2.0 m 0 - 2.6 m -
Requirements
18 Gas Fire Front 70-75
19
1
4,128
123
100
Y
0.25 m
X
114
110/111/113
Concentric flue connection on appliance Ø130-Ø200 mm
Y
(min. - max.)
X
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance
is Ø130-Ø200 mm
0.5 - 1.0 m 0 - 1.6 m -
1.0 - 3.0 m 0 - 4.6 m -
Requirements
Gas Fire Front 70-75 19
19
1
4,128
114
100
110/111/
113
110/111/113
0.16 m
14
114
110/113
X2
X1
Y1
Y2
Concentric flue connection on appliance Ø130-Ø200 mm
Y1
(min. - max.)
X1
(min. - max.)
Y2
(min. - max.)
X2
(min. - max.)
Flue gas restriction plate
width
Concentric connection on
the appliance is Ø130-
Ø200 mm
0 - 0.5 m 0 - 0.5 m 0.5 - 1.0 m 0 - 0.6 m -
0.5 - 1.0 m 0 - 0.5 m 0 - 0.5 m 0 - 0.6 m -
1.0 - 3.0 m 0 - 1.0 m 0.5 - 2.0 m 0 - 0.6 m -
1.0 - 3.0 m 0 - 3.0 m 1.0 - 3.0 m 0 - 0.6 m -
Requirements
20 Gas Fire Front 70-75
119
1
4,128
123
Y
0.25 m
X
114
110/111/113
Concentric flue connection on appliance Ø130-Ø200 mm
Y
(min. - max.)
X
(min. - max.)
Flue gas restriction plate width
Concentric connection on the appliance
is Ø130-Ø200 mm
0 - 0.5 m 0 - 0.6 m -
0.5 - 1.0 m 0 - 3.6 m -
1.0 - 3.0 m 0 - 8.6 m -
Requirements
Gas Fire Front 70-75 21
5 Technical specification
5.1 Gas Fire Front 70-75 PF2 with Floating Frame
* = Gas connection
Technical specification
22 Gas Fire Front 70-75
5.2 Gas Fire Front 70-75 PF2 with Floating Frame +
* = Gas connection
Technical specification
Gas Fire Front 70-75 23
5.3 Gas Fire Front 70-75 PF2 with Floating Frame and adjustable
legs
With optional adjustable legs
* = Gas connection
** = Maximum height with adjustable legs
Technical specification
24 Gas Fire Front 70-75
5.4 Gas Fire Front 70-75 PF2 with Floating Frame + and convection
casing
With optional convection case
Technical specification
Gas Fire Front 70-75 25
5.5 Gas Fire Front 70-75 PF2 with Hidden Door
* = Gas connection
Technical specification
26 Gas Fire Front 70-75
5.6 Gas Fire Front 70-75 PF2 with Hidden Door +
* = Gas connection
Technical specification
Gas Fire Front 70-75 27
5.7 Gas Fire Front 70-75 PF2 with Hidden Door and adjustable legs
With optional adjustable legs
* = Gas connection
** = Maximum height with adjustable legs
Technical specification
28 Gas Fire Front 70-75
5.8 Gas Fire Front 70-75 PF2 with Hidden Door and convection
casing
With optional convection case
* = Gas connection
Technical specification
Gas Fire Front 70-75 29
5.9 Dimensions of the restriction plate
Width of the delivered flue restriction plates in mm
Concentric flue connection Ø100 - Ø150 Concentric flue connection Ø130 - Ø200
Roof-mounted outlet Horizontal wall outlet
30 mm 40 mm
40 mm 50 mm
50 mm 65 mm
65 mm 80 mm
Technical specification
30 Gas Fire Front 70-75
6 Available components for the concentric flue
system - natural draught
Caution:
Observe the installation instructions that are supplied with the components of
the concentric flue system.
The appliance with extraction of the flue gasses by natural draught, in combination with
the concentric flue system [Ø100 mm - Ø150 mm] and/or [Ø130 mm - Ø200 mm] (rigid
and/or flexible) for the brand types mentioned below, has been approvedin accordance
with the European CE-norm for gas appliances and may therefore beused only with these
systems.
Manufacturer system
Bellfires Muelink & Grol system
Poujoulat DUOGAS system
Ontop Metaloterm US system
Jeremias/STB (STB = Schoorsteen Techniek-
Brummen NL) H-Twin system
Jeremias TWIN-GAS system
Modinox PLA system
The permitted components for these systems are listedin this chapter. The guarantee on
the appliance lapses if it is installed, fully or partially,with other components or a different
flue system.The concentric flue [Ø100 mm - Ø150 mm] and [Ø130 mm - Ø200 mm]
systems can beused with either a newly-built or existing chimney.
Make sure that the wall or roof termination kit that is used for the installation of the
concentric flue system is also listed in the available parts list.
6.1 Appliance part list
Fig No. Description
1 Gas fire; Concentric flue connection Ø130/Ø200 mm or Ø100/Ø150 mm.
2 -
3 -
4Restriction plate (The different sizes restriction plates are supplied with every appli-
ance).
5 Chimney, min. Ø150 mm internal, totally gas tight.
6 Chimney or fireproof sleeving. min. Ø160 mm internal.
7 Ø100 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
8 Ø150 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
9 -
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 31
6.2 Bellfires - Muelink & Grol system Ø100 - Ø150
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
10
302289 Twin-wall balanced flue
pipe. L= 500 mm.
346236
Twin-wall balanced flue
pipe. L= 500 mm.
BLACK
11
302290 Twin-wall balanced flue
pipe. L= 1000 mm.
346234
Twin-wall balanced flue
pipe. L= 1000 mm.
BLACK
12
302291
Telescopic twin-wall
balanced flue pipe, L=
min. 325 / max. 440
mm.
346511
Telescopic twin-wall
balanced flue pipe, L=
min. 965 / max. 1750
mm.
13
302292
Adjustable length twin-
wall balanced flue pipe,
L= 500 mm.
346237
Adjustable length twin-
wall balanced flue pipe,
L= 500 mm. BLACK
14
302299 Twin-wall balanced flue
elbow 90°. (smooth)
346238
Twin-wall balanced flue
elbow 90°. (smooth),
black
Available components for the concentric flue system -
natural draught
32 Gas Fire Front 70-75
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
14
302297 Twin-wall balanced flue
elbow 90°. (ribbed)
346239
Twin-wall balanced flue
elbow 90°. (segment)
BLACK
15
302298 Twin-wall balanced flue
elbow 45°. (ribbed)
346240
Twin-wall balanced flue
elbow 45°. (segment)
BLACK
329514 Twin-wall balanced flue
elbow 30°. (ribbed)
346507 Twin-wall balanced flue
elbow 15°. (segment)
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 33
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
16 302295
Vertical (roof) termina-
tion kit, L= 1360 mm.
ANTHRACITE
17 302212
Adjustable roof flash-
ing. Roof pitch 20° - 45°
(**),with lead flashing.
18 302213 Roof flashing for exist-
ing chimney or flat roof.
19
302296
Horizontal (wall) termi-
nation kit, L= 600 mm
(adjustable), including
a set of wall spacer
plates. ANTHRACITE
346241
Horizontal (wall) termi-
nation kit, L= 600 mm
(adjustable), including
a set of wall spacer
plates. Stainless steel.
BLACK
●●●
343949
Horizontal (wall) termi-
nation kit, L= 600 mm
(adjustable), including
a set of wall spacer
plates. Stainless steel.
20 302293
Stainless steel locking
band Ø150 mm, quick-
fastening.
21 302210 Silicone seal Ø150 mm.
Available components for the concentric flue system -
natural draught
34 Gas Fire Front 70-75
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
23 302215 Wall strap.
24 302214 Set of ceiling finishing
plates / Fire stops.
25 302189
Ceiling plate for transi-
tion Ø100 mm / Ø150
mm rigid -Ø100 mm
flex.).
26 302278
Stainless steel adapt-
er piece (100) from
appliance to flexible,
Ø100 mm external (rig-
id) x Ø107 mm inter-
nal (flex.). [appliance
- Ø100 mm flex.] and
[Ø100 mm rigid - Ø100
mm flex.].
27 302279
Stainless steel adapter
piece (150) fire to flexi-
ble, Ø148 mm external
(rigid) x Ø148 mm in-
ternal (flex.)[appliance -
Ø150 mm flex.].
28 302217
Stainless steel locking
band Ø150 mm. For
adapter 150 [appliance
- Ø150 mm (flex.)],
Screw-fastening.
29 303776
Stainless steel screws
Ø3.5 mm x 9.5 mm.
For securing the flexible
concentric flue. (Mini-
mum 3 screws per con-
nection).
30 304041
Hose clamp Ø100 mm.
(Minimum 2 per con-
nection).
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 35
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
31 304042
Hose clamp Ø150 mm.
(Minimum 2 per con-
nection)
32 302307
Vertical (roof) termina-
tion kit, L = 610 mm.
Suitable for a flexible
flue system. ANTHRA-
CITE
33 302301 Concentric T-piece with
gauging orifice.
34 302302
Concentric pipe with
gauging orifice, L = 165
mm.
35 302303 90° concentric bend
with inspection panel.
36 321948 Universal wall / floor
support Ø150 mm
(*)Color
Stainless steel, polished
antr. : Anthracite or Black color lacquer, matt
(**) Adjustable roof flashing for a slope > 45° can be supplied on request.
When installing a balanced-flue “closed” gas appliance in an existing chimney, ensure
stainlesssteel flexible liners (Ø100 mm or Ø130 mm) conforming with EN 1856-2 are
Available components for the concentric flue system -
natural draught
36 Gas Fire Front 70-75
used to extractthe flue gasses. The temperature classification of the flexible pipe must be
at least T450.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 37
6.3 Bellfires - Muelink & Grol system Ø130 - Ø200
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
100 302319
Concentric reduc-
tion of Ø130 /
Ø200 to Ø100 /
Ø150
110 302308
Twin-wall balanced
flue pipe. L= 500
mm.
111 302309
Twin-wall balanced
flue pipe. L= 1000
mm.
112
346509
Telescopic twin-
wall balanced flue
pipe, L= min. 325 /
max. 440 mm.
346512
Telescopic twin-
wall balanced flue
pipe, L= min. 965 /
max. 1750 mm.
113 302310
Adjustable length
twin-wall balanced
flue pipe, L= 500
mm.
Available components for the concentric flue system -
natural draught
38 Gas Fire Front 70-75
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
114 302314
Twin-wall balanced
flue elbow 90°. (rib-
bed)
115 302315
Twin-wall balanced
flue elbow 45°. (rib-
bed)
346510
Twin-wall balanced
flue elbow 30°. (rib-
bed)
346508
Twin-wall balanced
flue elbow 15°.
(segment)
119
302313
Horizontal (wall)
termination kit, L=
600 mm (adjusta-
ble), including a
set of wall spacer
plates. ANTHRA-
CITE
343950
Horizontal (wall)
termination kit, L=
600 mm (adjusta-
ble), including a
set of wall spacer
plates. Stainless
steel.
120 302311
Stainless steel
locking band Ø200
mm, quick-fasten-
ing.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 39
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
121 302248 Silicone seal Ø200
mm.
123 302251 Wall strap.
124 302250
Set of ceiling fin-
ishing plates / Fire
stops.
126 302281
Stainless steel
adapter piece
(130) from appli-
ance to flexible,
Ø130 mm external
(rigid) x Ø137 mm
internal (flex.). [ap-
pliance - Ø130 mm
flex.] and [Ø130
mm rigid - Ø130
mm flex.].
127 302282
Stainless steel
adapter piece
(200) appliance to
flexible, Ø198 mm
external (rigid) x
Ø198 mm internal
(flex.)[appliance -
Ø200 mm flex.].
128 302257
Stainless steel
locking band Ø200
mm. For adapter
200 [appliance -
Ø2050 mm (flex.)],
Screw-fastening.
129 303776
Stainless steel
screws Ø3.5 mm x
9.5 mm. For secur-
ing the flexible con-
centric flue. (Mini-
mum 3 screws per
connection).
Available components for the concentric flue system -
natural draught
40 Gas Fire Front 70-75
Fig.
No.
Bellfires
Art./ Order
No.
Description
Color (*) Application
stainless
steel antr. rigid flex
130 304045
Hose clamp Ø130
mm. (Minimum 2
per connection).
131 304046
Hose clamp Ø200
mm. (Minimum 2
per connection)
(*)Color
Stainless steel, polished
antr. : Anthracite or Black color lacquer, matt
(**) Adjustable roof flashing for a slope > 45° can be supplied on request.
When installing a balanced-flue “closed” gas appliance in an existing chimney, ensure
stainlesssteel flexible liners (Ø100 mm or Ø130 mm) conforming with EN 1856-2 are
used to extractthe flue gasses. The temperature classification of the flexible pipe must be
at least T450.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 41
6.4 Poujoulat - DUOGAS system Ø100 - Ø150
Fig
No.
Poujoulat
Art./ Order
No.
Description
34100403 Twin-wall balanced flue pipe, L= 250 mm.
10 34100404 Twin-wall balanced flue pipe. L= 450 mm.
11 34100405 Twin-wall balanced flue pipe. L= 950 mm.
12 34100429 Telescopic twin-wall balanced flue pipe, L= min. 390 /
max. 640 mm.
14 34100441 Twin-wall balanced flue elbow 90°.
15 34100421 Twin-wall balanced flue elbow 45°.
15 34100411 Twin-wall balanced flue elbow 30°.
15 34100401 Twin-wall balanced flue elbow 15°.
Available components for the concentric flue system -
natural draught
42 Gas Fire Front 70-75
Fig
No.
Poujoulat
Art./ Order
No.
Description
16 34100654 Vertical (roof) termination kit, L= 140 mm .
17 45150171 Roof flashing, suitable for a brick roof, with a roof pitch
of 15°- 30°.
17 45150170 Roof flashing, suitable for a tiled roof, with a roof pitch
of 15°- 30°.
17 45150172 Roof flashing, suitable for a brick roof, with a roof pitch
of 30°- 45°.
17 45150173 Roof flashing, suitable for a tiled roof, with a roof pitch
of 30°- 45°.
18 45150169 Roof flashing for existing chimney or flat roof.
19 34100610 Horizontal (wall) termination kit, L= min. 365 mm / max.
585 mm.
20 45150076 Stainless steel locking band Ø150 mm, quick-fastening.
23 45150072 Wall strap, Ø150 mm.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 43
Fig
No.
Poujoulat
Art./ Order
No.
Description
24 37100442 Ceiling/wall plate with spacers and ventilation grooves.
24 37100425 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 0°- 10°.
24 37100426 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 10°- 30°.
24 37100427 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 30°- 40°.
24 37100428 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 40°- 50°.
34 34100407 Concentric pipe with inspection opening, L= 250 mm.
36 45150165 Roof support, (universal) Ø150 mm.
36 45150081 Floor support, (universal) Ø150 mm.
37 34100611
Adapter: Bellfires Ø100-150 mm → Poujoulat DUOGAS
Ø100-150 mm(Appliance 100/150 → Poujoulat DUO-
GAS 100/150)
100 34100614
Adapter: Bellfires Ø130-200 mm → Poujoulat DUOGAS
Ø100-150 mm(Appliance 130/200 → Poujoulat DUO-
GAS 100/150)
101 34100613 Concentric reduction of Poujoulat DUOGAS Ø130-200
mm → Poujoulat DUOGAS Ø100-150 mm
Available components for the concentric flue system -
natural draught
44 Gas Fire Front 70-75
6.5 Poujoulat - DUOGAS system Ø130 - Ø200
Fig
No.
Poujoulat
Art./ Order
No.
Description
34130403 Twin-wall balanced flue pipe, L= 250 mm.
110 34130404 Twin-wall balanced flue pipe. L= 450 mm.
111 34130405 Twin-wall balanced flue pipe. L= 950 mm.
112 34130429 Telescopic twin-wall balanced flue pipe, L= min. 390 /
max. 640 mm.
114 34130441 Twin-wall balanced flue elbow 90°.
115 34130421 Twin-wall balanced flue elbow 45°.
115 34130411 Twin-wall balanced flue elbow 30°.
115 34130401 Twin-wall balanced flue elbow 15°.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 45
Fig
No.
Poujoulat
Art./ Order
No.
Description
119 34130610 Horizontal (wall) termination kit, L= min. 365 mm / max.
585 mm.
120 45200076 Stainless steel locking band Ø200 mm, quick-fastening.
123 45200072 Wall strap, Ø200 mm.
124 37130442 Ceiling/wall plate with spacers and ventilation grooves.
124
37130425 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 0°- 10°.
37130426 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 10°- 30°.
37130427 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 30°- 40°.
37130428 Set of ceiling finishing plates / Fire stops,suitable for a
roof pitch of 40°- 50°.
134 34130407 Concentric pipe with inspection opening, L= 250 mm.
136 45200165 Roof support, (universal) Ø200 mm.
136 45200081 Floor support, (universal) Ø200 mm.
137 34130615
Adapter: Bellfires Ø130-200 mm → Poujoulat DUOGAS
Ø130-200 mm(Appliance 1300/200 → Poujoulat DUO-
GAS 130/200)
Available components for the concentric flue system -
natural draught
46 Gas Fire Front 70-75
6.6 Ontop - Metaloterm US system Ø100 - Ø150
Fig.
No.
Ontop Art. /
Order No. Description
USA 10 Adapter for Bellfires appliances with Ø100-Ø150 mm
concentric connection.
US 25 10 Twin-wall balanced flue pipe, L = 250 mm.
10 US 50 10 Twin-wall balanced flue pipe. L= 500 mm.
11 US 100 10 Twin-wall balanced flue pipe. L= 1000 mm.
12 USPP 10 Telescopic twin-wall balanced flue pipe, L= min. 60 /
max. 250 mm.
14 USB 90 10 Twin-wall balanced flue elbow 90°.
15 USB 45 10 Twin-wall balanced flue elbow 45°.
15 USB 30 10 Twin-wall balanced flue elbow 30°.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 47
Fig.
No.
Ontop Art. /
Order No. Description
15 USB 15 10 Twin-wall balanced flue elbow 15°.
16 USDVC2 10 Vertical (roof) termination kit, L= 375 mm.
16 USSR 10 Storm collar Ø150 mm.
17 USLS 10 Adjustable roof flashing. Roof pitch 20° - 45°, with lead
flashing.
17 USDH 10 Roof flashing plate for roof pitch 5°- 30°.
18 USDP 10 Roof flashing for existing chimney or flat roof.
18 USDPAL 10 Roof flashing - Aluminum - For existing chimney or flat
roof.
19 USDHC5 10 Horizontal (wall) termination kit, L= 475 mm (adjusta-
ble).
20 USKB 10 Locking band, quick-fastening.
Available components for the concentric flue system -
natural draught
48 Gas Fire Front 70-75
Fig.
No.
Ontop Art. /
Order No. Description
21 USAB 10 Cover band, screw-fastening.
23 USMB 10 Wall strap, adjustable.
23 USEB 10 Fitting bracket.
24 USCP 10 Set of ceiling finishing plates / Fire stops /Centering
plates.
24 USDQ 10 Roof support.
25 USSAN 10 Renovation set.
25 USSAN1 10 Top of renovation set.
25 USSAN2 10 Bottom renovation set.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 49
Fig.
No.
Ontop Art. /
Order No. Description
28 USKBS 10 Locking band, screw-fastening.
USI 10 Concentric pipe with inspection panel,L= 250 mm.
34 USEM 10 Concentric pipe with gauging orifice,L= 150 mm.
35 USBI 10 90° concentric bend with inspection panel.
USR 10 Rosette smooth Ø150 mm.
USMPG 10 Wall plate large Ø150 mm, square 300 mm.
USAH 10 Spacer bracket.
USVG 10 13 Concentric reduction of Ø100-Ø150 mm → Ø130-Ø200
mm.
Available components for the concentric flue system -
natural draught
50 Gas Fire Front 70-75
6.7 Ontop - Metaloterm US system Ø130 - Ø200
Fig.
No.
Ontop Art. /
Order No. Description
USA 13 Adapter for Bellfires appliances with Ø100-Ø150 mm
concentric connection.
US 25 13 Twin-wall balanced flue pipe, L = 250 mm.
110 US 50 13 Twin-wall balanced flue pipe. L= 500 mm.
111 US 100 13 Twin-wall balanced flue pipe. L= 1000 mm.
112 USPP 13 Telescopic twin-wall balanced flue pipe, L= min. 60 /
max. 250 mm.
114 USB 90 13 Twin-wall balanced flue elbow 90°.
115 USB 45 13 Twin-wall balanced flue elbow 45°.
115 USB 30 13 Twin-wall balanced flue elbow 30°.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 51
Fig.
No.
Ontop Art. /
Order No. Description
115 USB 15 13 Twin-wall balanced flue elbow 15°.
116 USDVC2 13 Vertical (roof) termination kit, L= 375 mm.
116 USSR 13 Storm collar Ø150 mm.
117 USLS 13 Adjustable roof flashing. Roof pitch 20° - 45°, with lead
flashing.
117 USDH 13 Roof flashing plate for roof pitch 5°- 30°.
118 USDP 13 Roof flashing for existing chimney or flat roof.
118 USDPAL 13 Roof flashing - Aluminum - For existing chimney or flat
roof.
119 USDHC4 13 Horizontal (wall) termination kit, L= 475 mm (adjusta-
ble).
120 USKB 13 Locking band, quick-fastening.
Available components for the concentric flue system -
natural draught
52 Gas Fire Front 70-75
Fig.
No.
Ontop Art. /
Order No. Description
121 USAB 13 Cover band, screw-fastening.
123 USMB 13 Wall strap, adjustable.
123 USEB 13 Fitting bracket.
124 USCP 13 Set of ceiling finishing plates / Fire stops /Centering
plates.
124 USDQ 13 Roof support.
125 USSAN 13 Renovation set.
125 USSAN1 13 Top of renovation set.
125 USSAN1 13 Bottom renovation set.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 53
Fig.
No.
Ontop Art. /
Order No. Description
128 USKBS 13 Locking band, screw-fastening.
USI 13 Concentric pipe with inspection panel,L= 250 mm.
134 USEM 13 Concentric pipe with gauging orifice,L= 150 mm.
135 USBI 13 90° concentric bend with inspection panel.
USR 13 Rosette smooth Ø200 mm.
USMPG 13 Wall plate large Ø200 mm, square 350 mm.
Available components for the concentric flue system -
natural draught
54 Gas Fire Front 70-75
Fig.
No.
Ontop Art. /
Order No. Description
USAH 13 Spacer bracket.
USVG 13 10 Concentric reduction of Ø130-Ø200 mm → Ø100-Ø150
mm.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 55
6.8 Jeremias/STB - H-Twin system Ø100 - Ø150
Fig.
No.
Jeremias
Art. / Order
No.
Description
11 ATWINL
13100-150 Twin-wall balanced flue pipe. L= 1000 mm.
10 ATWINL
14100-150 Twin-wall balanced flue pipe. L= 500 mm.
10 ATWINL
15100-150 Twin-wall balanced flue pipe. L= 250 mm.
12 H-TWIN
742100-150
Telescopic twin-wall balanced flue pipe, L= min. 1100 /
max. 1400 mm.
12 H-TWIN
467100-150
Telescopic twin-wall balanced flue pipe, L= min. 1100 /
max. 1900 mm.
12 ATWIN
197100-150
Telescopic twin-wall balanced flue pipe, L= min. 600 /
max. 900 mm.
15 ATWIN 16
100-150 Twin-wall balanced flue elbow 15°.
Available components for the concentric flue system -
natural draught
56 Gas Fire Front 70-75
Fig.
No.
Jeremias
Art. / Order
No.
Description
15 ATWIN 17
100-150 Twin-wall balanced flue elbow 30°.
15 ATWIN 18
100-150 Twin-wall balanced flue elbow 45°.
14 ATWIN
60100-150 Twin-wall balanced flue elbow 90°.
14 ATWIN
60F100-150
Twin-wall balanced flue elbow 90° - Short.Especially for
connection to a wall termination.
16 A
463100-150
Roof termination - long, with pipe,L = 1080 mm, Verti-
cal.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 57
Fig.
No.
Jeremias
Art. / Order
No.
Description
16 ATWIN
92100-150 Roof termination - short with pipe,L = 300 mm, Vertical.
32
ATWIN
92pe100-15
0
Roof termination, with pipe,L = 495 mm, Vertical, with
roof flashing for existing chimney or flat roof.
17
ATWIN
45DD
100-150
Roof flashing for roof pitch 30°,with lead flashing and
storm collar.
17
ATWIN
60DD
100-150
Roof flashing for roof pitch 45°,with lead flashing and
storm collar.
ATWIN 307
100-150 Storm collar.
24 ADBL-
DW100-150 Set of ceiling finishing plates / Fire stops.
20 ATWIN
45100-150
Locking band, Screw-fastening (Standard on all com-
ponents).
23 ATWIN
22100-150 Wall strap, adjustable.
23 ATWIN
23100-150 Wall strap, distance adjustable 60-250 mm.
Available components for the concentric flue system -
natural draught
58 Gas Fire Front 70-75
Fig.
No.
Jeremias
Art. / Order
No.
Description
19 A681100-15
0
Horizontal (wall) termination kit, L= 495 mm (horizontal-
ly adjustable), including one set of wall spacer plates.
33 H-TWIN
752100-150
Concentric T-piece with gauging orifice. Inspection
panel with cover cap and condensation-opening.
ATWIN 465
100-150
Adapter: H-TWIN Ø100-150 → Flex Stainless steel ;
Ø100 mm Incl. Ceiling plate 300x300 mm.
ATWIN
466100-150
Adapter: Flex Stainless steel; Ø100 mm → H-TWIN
Ø100-150 Incl. Chimney(ceiling)plate 300x300 mm.
36 ASDH2
100-150 Universal wall / floor supportØ150 mm.
100 A464 130 Concentric reduction of H-TWIN Ø130 / Ø200 mm →
H-TWIN Ø100 / Ø150 mm.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 59
6.9 Jeremias/STB - H-Twin system Ø130 - Ø200
Fig.
No.
Jeremias
Art. / Order
No.
Description
111 ATWINL
13130-200 Twin-wall balanced flue pipe. L= 1000 mm.
110 ATWINL
14130-200 Twin-wall balanced flue pipe. L= 500 mm.
110 ATWINL
15130-200 Twin-wall balanced flue pipe. L= 250 mm.
112 H-TWIN
742130-200
Telescopic twin-wall balanced flue pipe, L= min. 1100 /
max. 1400 mm.
112 H-TWIN
467130-200
Telescopic twin-wall balanced flue pipe, L= min. 1100 /
max. 1900 mm.
112 ATWIN
197130-200
Telescopic twin-wall balanced flue pipe, L= min. 600 /
max. 900 mm.
115 ATWIN 16
130-200 Twin-wall balanced flue elbow 15°.
Available components for the concentric flue system -
natural draught
60 Gas Fire Front 70-75
Fig.
No.
Jeremias
Art. / Order
No.
Description
115 ATWIN 17
130-200 Twin-wall balanced flue elbow 30°.
115 ATWIN 18
130-200 Twin-wall balanced flue elbow 45°.
114 ATWIN
60130-200 Twin-wall balanced flue elbow 90°.
114 ATWIN
60F130-200
Twin-wall balanced flue elbow 90° - Short.Especially for
connection to a wall termination.
124 ADBL-
DW130-200 Set of ceiling finishing plates / Fire stops.
120 ATWIN
45130-200
Locking band, Screw-fastening (Standard on all com-
ponents).
123 ATWIN
22130-200 Wall strap, adjustable.
123 ATWIN
23130-200 Wall strap, distance adjustable 60-250 mm.
119 A681130-20
0
Horizontal (wall) termination kit, L= 495 mm (horizontal-
ly adjustable), including one set of wall spacer plates.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 61
Fig.
No.
Jeremias
Art. / Order
No.
Description
133 H-TWIN
752130-200
Concentric T-piece with gauging orifice. Inspection
panel with cover cap and condensation-opening.
ATWIN 465
130-200
Adapter: H-TWIN Ø130-200 → Flex Stainless steel ;
Ø130 mm Incl. Ceiling plate 300x300 mm.
ATWIN
466130-200
Adapter: Flex Stainless steel; Ø130 mm → H-TWIN
Ø130-200 Incl. Chimney(ceiling)plate 300x300 mm.
136 ASDH2
130-200 Universal wall / floor supportØ200 mm.
100 A464 130 Concentric reduction of H-TWIN Ø130 / Ø200 mm →
H-TWIN Ø100 / Ø150 mm.
Available components for the concentric flue system -
natural draught
62 Gas Fire Front 70-75
6.10 Jeremias - TWIN-GAS system Ø100 - Ø150
Fig.
No.
Jeremias
Art. / Order
No.
Description
TWG163410
0-150
Bellfires Appliance connection / AdapterBellfires
Ø100/150 mm → Jeremias TWIN-GAS Ø100/150 mmL
= 160 mmIncluding locking band (2x).
11 TWG13100-
150
Twin-wall balanced flue pipe, L = 1000 mmIncluding
locking band.
10 TWG14100-
150
Twin-wall balanced flue pipe, L = 500 mmIncluding
locking band.
10 TWG15100-
150
Twin-wall balanced flue pipe, L = 250 mmIncluding
locking band.
TWG180110
0-150
Twin-wall balanced flue pipe, L = 1000 mmwith 4
spacer brackets on the outsideIncluding locking band.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 63
Fig.
No.
Jeremias
Art. / Order
No.
Description
12 TWG50100-
150
Telescopic twin-wall balanced flue pipe,L= min. 330 /
max. 420 mmIncluding locking band.
15 TWG16100-
150
Twin-wall balanced flue elbow 15°. Including locking
band.
15 TWG17100-
150
Twin-wall balanced flue elbow 30°. Including locking
band.
15 TWG18100-
150
Twin-wall balanced flue elbow 45°. Including locking
band.
14 TWG60100-
150
Twin-wall balanced flue elbow 90°. Including locking
band.
14 TWG178610
0-150
Twin-wall balanced flue elbow 90° - with support leg
Including locking band and sealing cap under.
14 TWG167610
0-150
Twin-wall balanced flue elbow 90° - short - eccen-
tric.Especially for connection to a wall termination
TWG1619Including locking band.
Available components for the concentric flue system -
natural draught
64 Gas Fire Front 70-75
Fig.
No.
Jeremias
Art. / Order
No.
Description
16 TWG272100
-150
Roof termination (vertical) L= 615 mm.Including locking
band.
17 TW53150 Roof flashing with a roof pitch of 5° - 15°with flex. alu-
flashing and storm collar.
17 TW59 150 Roof flashing with a roof pitch of 16° - 25°with flex.
alu-flashing and storm collar.
17 TW38 150 Roof flashing with a roof pitch of 26° - 35°with flex.
alu-flashing and storm collar.
17 TW54 150 Roof flashing with a roof pitch of 36° - 45°with flex.
alu-flashing and storm collar.
18 TW52150 Roof flashing for existing chimney or flat roofwith storm
collar.
KL72150 Storm collar(spare part).
19 TWG161910
0-150
Wall termination kit, L= 600 mm (horizontal)Adjustable.
Incl. locking band and one set of wall spacer plates.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 65
Fig.
No.
Jeremias
Art. / Order
No.
Description
20 TW45150 Locking band, screw-fastening(spare part).
21 ALBI26150 Silicone sealing ring for outer pipe(spare part).
23 ZU-
WA704150 Wall strap. Distance to the wall: WA= 50 mm.
ZU-
WA891130
Extension pieces for the wall strap ZUWA704L= 130
mm.
ZU-
WA891200
Extension pieces for the wall strap ZUWA704L= 200
mm.
ZU-
WA891250
Extension pieces for the wall strap ZUWA704L= 250
mm.
ZUWA706 Extension pieces for the wall strap ZUWA704L= 400
mm, WA = 50 - 360 mm.
24 ZU-
DA074150
Set of ceiling finishing plates / Fire stopsfor a flat roof :
0°.
24 ZU-
DA99V150
Set of ceiling finishing plates / Fire stopsfor a pitched
roof : 0° - 30°.
24 ZU-
DA98V150
Set of ceiling finishing plates / Fire stopsfor a pitched
roof : 31° - 45°.
Available components for the concentric flue system -
natural draught
66 Gas Fire Front 70-75
Fig.
No.
Jeremias
Art. / Order
No.
Description
24
ZU-
DA99VHL15
0
Set of ceiling finishing plates / Fire stops with ventila-
tion openings for a pitched roof : 0° - 30°.
24
ZU-
DA98VHL15
0
Set of ceiling finishing plates / Fire stopswith ventilation
openings for a pitched roof : 31° - 45°.
25 FD08 100 Adapter: TWIN-GAS to FLEX. (only for the inner pipe
Ø100 mm).
25 TWG1276D
100-150
Chimney-/flat roof-/ceiling - platewith adapter: FLEX to
TWIN-GAS.
25 ZU-
WA1618100 Adapter: TWIN-GAS to ‘Schaft’ (DE).
25 TWG173210
0-150
Chimney-/flat roof-/ceiling - platewith adapter: Ø100 rig-
id/flex. to TWIN-GAS .
33 TWG317100
-150 Concentric T-piece 90°.Including locking band.
34 TWG51100-
150
Concentric pipe with gauging orificeL= 200 mm. Includ-
ing locking band.
35 TWG10
100-150
Concentric pipe, L= 300 mmwith cleaning opening/in-
spection panel.Including locking band.
35 TWG19100-
150
Concentric elbow 90°with cleaning opening/inspection
panel.Including locking band.
36 TWG05100-
150
Base plate/Cover-under with 2x ½” gauging orifice,
sealing cap and condensate drain at the bottom.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 67
Fig.
No.
Jeremias
Art. / Order
No.
Description
36 TWG07100-
150 Base plate / floor support.
DW391
Wall support with transverse supportType I: 350 mm
- Distance to wall: WA= max. 50 mm.
DW392
Wall support with transverse supportType II: 500 mm
- Distance to wall: WA= 50 - 150 mm.
DW393
Wall support with transverse supportType III: 750 mm
- Distance to wall: WA= 150 - 250 mm.
DW407
Wall support with transverse supportType IV: 1030 mm
- Distance to wall: WA= 250 - 360 mm.
(17-
24)
LUX-
ECO150
Insulation roof flashing, L= Max. 500 mm (adjustable).
Wall thickness LUX-ECO Insulation: min. 25 mm.
(19) LUX-
ECO150
Insulation wall flashing, L= Max. 360 mm(adjustable).
Wall thickness LUX-ECO Insulation: min. 25 mm.
Available components for the concentric flue system -
natural draught
68 Gas Fire Front 70-75
6.11 Jeremias - TWIN-GAS system Ø130 - Ø200
Fig.
No.
Jeremias
Art. / Order
No.
Description
TWG163413
0-200
Bellfires Appliance connection / AdapterBellfires
Ø130/200 mm → Jeremias TWIN-GAS Ø130/200 mmL
= 160 mmIncluding locking band (2x).
111 TWG13130-
200
Twin-wall balanced flue pipe, L = 1000 mmIncluding
locking band.
110 TWG14130-
200
Twin-wall balanced flue pipe, L = 500 mmIncluding
locking band.
110 TWG15130-
200
Twin-wall balanced flue pipe, L = 250 mmIncluding
locking band.
TWG180113
0-200
Twin-wall balanced flue pipe, L = 1000 mmwith 4
spacer brackets on the outsideIncluding locking band.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 69
Fig.
No.
Jeremias
Art. / Order
No.
Description
112 TWG50130-
200
Telescopic twin-wall balanced flue pipe,L= min. 330 /
max. 420 mmIncluding locking band.
115 TWG16130-
200
Twin-wall balanced flue elbow 15°. Including locking
band.
115 TWG17130-
200
Twin-wall balanced flue elbow 30°. Including locking
band.
115 TWG18130-
200
Twin-wall balanced flue elbow 45°. Including locking
band.
114 TWG60130-
200
Twin-wall balanced flue elbow 90°. Including locking
band.
114 TWG178613
0-200
Twin-wall balanced flue elbow 90° - with support leg
Including locking band and sealing cap under.
114 TWG167613
0-200
Twin-wall balanced flue elbow 90° - short - eccen-
tric.Especially for connection to a wall termination
TWG1619Including locking band.
Available components for the concentric flue system -
natural draught
70 Gas Fire Front 70-75
Fig.
No.
Jeremias
Art. / Order
No.
Description
116 TWG272130
-200
Roof termination (vertical) L= 615 mm.Including locking
band.
117 TW53200 Roof flashing with a roof pitch of 5° - 15°with flex. alu-
flashing and storm collar.
117 TW59 200 Roof flashing with a roof pitch of 16° - 25°with flex.
alu-flashing and storm collar.
117 TW38 200 Roof flashing with a roof pitch of 26° - 35°with flex.
alu-flashing and storm collar.
117 TW54 200 Roof flashing with a roof pitch of 36° - 45°with flex.
alu-flashing and storm collar.
118 TW52200 Roof flashing for existing chimney or flat roofwith storm
collar.
KL72200 Storm collar(spare part).
119 TWG161913
0-200
Wall termination kit, L= 600 mm (horizontal)Adjustable.
Incl. locking band and one set of wall spacer plates.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 71
Fig.
No.
Jeremias
Art. / Order
No.
Description
120 TW45200 Locking band, screw-fastening(spare part).
121 ALBI26200 Silicone sealing ring for outer pipe(spare part).
123 ZU-
WA704200 Wall strap. Distance to the wall: WA= 50 mm.
ZU-
WA891130
Extension pieces for the wall strap ZUWA704L= 130
mm.
ZU-
WA891200
Extension pieces for the wall strap ZUWA704L= 200
mm.
ZU-
WA891250
Extension pieces for the wall strap ZUWA704L= 250
mm.
ZUWA706 Extension pieces for the wall strap ZUWA704L= 400
mm, WA = 50 - 360 mm.
124 ZU-
DA074200
Set of ceiling finishing plates / Fire stopsfor a flat roof :
0°.
124 ZU-
DA99V200
Set of ceiling finishing plates / Fire stopsfor a pitched
roof : 0° - 30°.
124 ZU-
DA98V200
Set of ceiling finishing plates / Fire stopsfor a pitched
roof : 31° - 45°.
Available components for the concentric flue system -
natural draught
72 Gas Fire Front 70-75
Fig.
No.
Jeremias
Art. / Order
No.
Description
124
ZU-
DA99VHL20
0
Set of ceiling finishing plates / Fire stops with ventila-
tion openings for a pitched roof : 0° - 30°.
124
ZU-
DA98VHL20
0
Set of ceiling finishing plates / Fire stopswith ventilation
openings for a pitched roof : 31° - 45°.
125 FD08 130 Adapter: TWIN-GAS to FLEX. (only for the inner pipe
Ø100 mm).
125 TWG1276D
130-200
Chimney-/flat roof-/ceiling - platewith adapter: FLEX to
TWIN-GAS.
125 ZU-
WA1618130 Adapter: TWIN-GAS to ‘Schaft’ (DE).
125 TWG173213
0-200
Chimney-/flat roof-/ceiling - platewith adapter: Ø100 rig-
id/flex. to TWIN-GAS .
133 TWG317130
-200 Concentric T-piece 90°.Including locking band.
134 TWG51130-
200
Concentric pipe with gauging orificeL= 200 mm. Includ-
ing locking band.
135 TWG10
130-200
Concentric pipe, L= 300 mmwith cleaning opening/in-
spection panel.Including locking band.
135 TWG19130-
200
Concentric elbow 90°with cleaning opening/inspection
panel.Including locking band.
136 TWG05130-
200
Base plate/Cover-under with 2x ½” gauging orifice,
sealing cap and condensate drain at the bottom.
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 73
Fig.
No.
Jeremias
Art. / Order
No.
Description
136 TWG07130-
200 Base plate / floor support.
DW391
Wall support with transverse supportType I: 350 mm
- Distance to wall: WA= max. 50 mm.
DW392
Wall support with transverse supportType II: 500 mm
- Distance to wall: WA= 50 - 150 mm.
DW393
Wall support with transverse supportType III: 750 mm
- Distance to wall: WA= 150 - 250 mm.
DW407
Wall support with transverse supportType IV: 1030 mm
- Distance to wall: WA= 250 - 360 mm.
100 TWGR Concentric reduction Jeremias TWIN-GAS Ø130/Ø200
→ Jeremias TWIN-GAS Ø100/Ø150
LUX-
ECO200
Insulation roof flashing, L= Max. 500 mm (adjustable).
Wall thickness LUX-ECO Insulation: min. 25 mm.
(11
9)
LUX-
ECO200
Insulation wall flashing, L= Max. 360 mm(adjustable).
Wall thickness LUX-ECO Insulation: min. 25 mm.
Available components for the concentric flue system -
natural draught
74 Gas Fire Front 70-75
6.12 Modinox - PLA system Ø100 - Ø153
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
2PLAMAFM100BEL
Bellfires appli-
ance connec-
tion: Adapter
Bellfires
Ø100/150 mm
→ Modinox
PLA
Ø100/153
mm. L= 230
mm. INOX
2PLAMAFM100BELNO
Bellfires appli-
ance connec-
tion: Adapter
Bellfires
Ø100/150 mm
→ Modinox
PLA
Ø100/153
mm. L= 230
mm. INOX -
BLACK
10
2PLAELDR100250
Twin-wall bal-
anced flue
pipe, L= 250
mm., INOX
2PLAELDR100250NO
Twin-wall bal-
anced flue
pipe, L= 250
mm., INOX -
BLACK
10
2PLAELDR100330
Twin-wall bal-
anced flue
pipe, L= 330
mm., INOX
2PLAELDR100330NO
Twin-wall bal-
anced flue
pipe, L= 330
mm., INOX -
BLACK
10
2PLAELDR100500
Twin-wall bal-
anced flue
pipe, L= 500
mm., INOX
2PLAELDR100500NO
Twin-wall bal-
anced flue
pipe, L= 500
mm., INOX -
BLACK
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
11
2PLAELDR1001000
Twin-wall bal-
anced flue
pipe, L= 1000
mm., INOX
2PLAELDR1001000NO
Twin-wall bal-
anced flue
pipe, L= 1000
mm., INOX -
BLACK
12
2PLAELRE100500
Telescopic
twin-wall bal-
anced flue
pipe, L= min.
300 / max.
500 mm., IN-
OX
2PLAELRE100500NO
Telescopic
twin-wall bal-
anced flue
pipe, L= min.
300 / max.
500 mm., IN-
OX - BLACK
14
2PLACO90100
Twin-wall bal-
anced flue el-
bow 90°, IN-
OX
2PLACO90100NO
Twin-wall bal-
anced flue el-
bow 90°, IN-
OX - BLACK
15
2PLACO45100
Twin-wall bal-
anced flue el-
bow 45°, IN-
OX
2PLACO45100NO
Twin-wall bal-
anced flue el-
bow 45°, IN-
OX - BLACK
15
2PLACO30100
Twin-wall bal-
anced flue el-
bow 30°, IN-
OX
2PLACO30100NO
Twin-wall bal-
anced flue el-
bow 30°, IN-
OX - BLACK
Available components for the concentric flue system -
natural draught
76 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
15
2PLACO15100
Twin-wall bal-
anced flue el-
bow 15°, IN-
OX
2PLACO15100NO
Twin-wall bal-
anced flue el-
bow 15°, IN-
OX - BLACK
16
2PLACHAR100
Vertical (roof)
termination
cap, L= 360
mm, INOX
2PLACHAR100NO
Vertical (roof)
termination
cap, L= 360
mm, INOX -
BLACK
17
2DIVS5IN150
Roof flashing
for a roof pitch
of 5°- 30°, IN-
OX
2DIVS5IN150NO
Roof flashing
for a roof pitch
of 5°- 30°, IN-
OX - BLACK
17
2DIVS3IN150
Roof flashing
for a roof pitch
of 31°- 45°,
INOX
2DIVS3IN150NO
Roof flashing
for a roof pitch
of 31°- 45°,
INOX -
BLACK
17 2DIVRTS1
Roof tile fitting
for roof flash-
ing
17
2DIVCSOL153
Collar for roof
flashing, IN-
OX
2DIVCSOL153NO
Collar for roof
flashing, IN-
OX - BLACK
2DIVJOCO155
Sealing ring
for collar roof
flashing
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 77
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
17
2DIVS5PS160
Roof flashing,
standard
model, lead:
0,6mm thick,
for a roof pitch
of 5°- 30°,
with INOX
cone
2DIVS5PR160
Roof flashing,
large tile mod-
el, lead:
1,0mm thick,
for a roof pitch
of 5°- 30°,
with INOX
cone
2DIVS3PS160
Roof flashing,
standard
model, lead:
0,6mm thick,
for a roof pitch
of 31°- 45°,
with INOX
cone
2DIVS3PR160
Roof flashing,
large tile mod-
el, lead:
1,0mm thick,
for a roof pitch
of 31°- 45°,
with INOX
cone
17
2DIVC5LA153NO
Cone cover
for roof flash-
ing, lead, for a
roof pitch of
5°- 30°, INOX
- BLACK
2DIVC3LA153NO
Cone cover
for roof flash-
ing, lead, for a
roof pitch of
31°- 45°, IN-
OX - BLACK
18
2DIVSOIN150
Roof flashing
for existing
chimney or
flat roof, INOX
2DIVSOIN150NO
Roof flashing
for existing
chimney or
flat roof, INOX
- BLACK
Available components for the concentric flue system -
natural draught
78 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
19
2PLATHOR100
Horizontal
(wall) termina-
tion kit, with
rosettes, L=
min. 580 mm /
max. 780 mm.
INOX
2PLATHOR100NO
Horizontal
(wall) termina-
tion kit, with
rosettes, L=
min. 580 mm /
max. 780 mm.
INOX -
BLACK
20
2PLACOJO100
Locking band,
quick-fasten-
ing. INOX
2PLACOJO100NO
Locking band,
quick-fasten-
ing. INOX -
BLACK
21 2PLAJOIF100 Fiber seal
23
2PLACOMU100 Wall strap, IN-
OX
2PLACOMU100NO Wall strap, IN-
OX - BLACK
23 2PLASUPLR100
Wall support,
quick fasten-
ing
24 2PLACOCF100
Set of ceiling
finishing
plates / Fire
stops
24 2PLAPVEN100
Ceiling finish-
ing plate with
ventilation
openings
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 79
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
24
2PLAROSA100BT Rosette, IN-
OX
2PLAROSA100BTNO Rosette, IN-
OX - BLACK
2PLAROSA100BTBL Rosette, IN-
OX - WHITE
24
2PLAROSA100
Rosette with 4
mounting
holes, INOX
2PLAROSA100NO
Rosette with 4
mounting
holes, INOX -
BLACK
2PLAROSA100BL
Rosette with 4
mounting
holes, INOX -
WHITE
34
2PLAEMES100
Concentric
pipe with
gauging ori-
fice, L= 250
mm, INOX
2PLAEMES100NO
Concentric
pipe with
gauging ori-
fice, L= 250
mm, INOX -
BLACK
35 2PLAERAM100
Concentric
pipe with in-
spection/
cleaning
opening, L=
260 mm.
36 2PLACOSO100 Floor support
strap
36 2PLACTOS100 Roof strap
Available components for the concentric flue system -
natural draught
80 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
36 2PLAEPDS100
Clearance
roof/floor pas-
sage
25
2PLAADA71002020
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x200mm,
INOX
2PLAADA71002020NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x200mm,
INOX -
BLACK
●●●
25
2PLAADA71002525
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
250x250mm,
INOX
2PLAADA71002525NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
250x250mm,
INOX -
BLACK
●●●
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 81
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
25
2PLAADA71003030
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x300mm,
INOX
2PLAADA71003030NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x300mm,
INOX -
BLACK
●●●
25
2PLAADA71002040
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x400mm,
INOX
2PLAADA71002040NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x400mm,
INOX -
BLACK
●●●
25
2PLAADA71003040
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x400mm,
INOX
2PLAADA71003040NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x400mm,
INOX -
BLACK
●●●
Available components for the concentric flue system -
natural draught
82 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
25
2PLAADA61002020
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
200x200mm,
INOX
2PLAADA61002525
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
250x250mm,
INOX
2PLAADA61003030
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
300x300mm,
INOX
2PLAADA61002040
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
200x400mm,
INOX
2PLAADA61003040
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
300x400mm,
INOX
2PTGKIMU100
Insulation kit
ISOMU for
wall passage
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 83
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainles
steel antr. rigid flex
2PTGKIRA100 + la
pente
Insulation kit
ISORA for
pitched roof
passage
2PTGKIRAV100 + la
pente
Insulation kit
ISORA for
pitched roof
passage, roof
and floor, in-
cludes a junc-
tion collar and
4 ventilation
grilles
2PTGKIFO100
Insulation kit
FOURP for
ceiling pas-
sage. Com-
plete wood
floor kit
2PTGKIFO100BE
Insulation kit
FOURP for
ceiling pas-
sage. Com-
plete concrete
floor kit
2PTGKIFOV100
Insulation kit
FOURP for
ceiling + stor-
ey floor pas-
sage. Com-
plete wood
floor kit
2PTGKIFOVBE100
Insulation kit
FOURP for
ceiling + stor-
ey floor pas-
sage. Com-
plete concrete
floor kit
2PTGPPDR100BL
Ceiling finish-
ing plates -
Whit lac-
quered - Op-
tion for kit
FOURP
Available components for the concentric flue system -
natural draught
84 Gas Fire Front 70-75
6.13 Modinox - PLA system Ø130 - Ø200
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
2PLAMAFM130BEL
Bellfires appli-
ance connec-
tion: Adapter
Bellfires
Ø130/200 mm
→ Modinox
PLA
Ø130/200
mm. L= 230
mm. INOX
2PLAMAFM130BELNO
Bellfires appli-
ance connec-
tion: Adapter
Bellfires
Ø130/200 mm
→ Modinox
PLA
Ø130/200
mm. L= 230
mm. INOX -
BLACK
100
2PLAMAFM130100BEL
Bellfires appli-
ance connec-
tion: Adapter
Bellfires
Ø130/200 mm
→ Modinox
PLA
Ø100/153
mm. L= 180
mm. INOX
2PLAMAFM130100BEL
NO
Bellfires appli-
ance connec-
tion: Adapter
Bellfires
Ø130/200 mm
→ Modinox
PLA
Ø100/153
mm. L= 180
mm. INOX -
BLACK
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 85
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
100
2PLAMAFM130100
Adapter Modi-
nox PLA
Ø130/200 mm
→ Modinox
PLA
Ø100/153
mm. L= 225
mm. INOX
2PLAMAFM130100NO
Adapter Modi-
nox PLA
Ø130/200 mm
→ Modinox
PLA
Ø100/153
mm. L= 225
mm. INOX -
BLACK
110
2PLAELDR130250
Twin-wall bal-
anced flue
pipe, L= 250
mm., INOX
2PLAELDR130250NO
Twin-wall bal-
anced flue
pipe, L= 250
mm., INOX -
BLACK
110
2PLAELDR130330
Twin-wall bal-
anced flue
pipe, L= 330
mm., INOX
2PLAELDR130330NO
Twin-wall bal-
anced flue
pipe, L= 330
mm., INOX -
BLACK
110
2PLAELDR130500
Twin-wall bal-
anced flue
pipe, L= 500
mm., INOX
2PLAELDR130500NO
Twin-wall bal-
anced flue
pipe, L= 500
mm., INOX -
BLACK
111
2PLAELDR1301000
Twin-wall bal-
anced flue
pipe, L= 1000
mm., INOX
2PLAELDR1301000NO
Twin-wall bal-
anced flue
pipe, L= 1000
mm., INOX -
BLACK
Available components for the concentric flue system -
natural draught
86 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
112
2PLAELRE130500
Telescopic
twin-wall bal-
anced flue
pipe, L= min.
300 / max.
500 mm., IN-
OX
2PLAELRE130500NO
Telescopic
twin-wall bal-
anced flue
pipe, L= min.
300 / max.
500 mm., IN-
OX - BLACK
114
2PLACO90130
Twin-wall bal-
anced flue el-
bow 90°, IN-
OX
2PLACO90130NO
Twin-wall bal-
anced flue el-
bow 90°, IN-
OX - BLACK
115
2PLACO45130
Twin-wall bal-
anced flue el-
bow 45°, IN-
OX
2PLACO45130NO
Twin-wall bal-
anced flue el-
bow 45°, IN-
OX - BLACK
115
2PLACO30130
Twin-wall bal-
anced flue el-
bow 30°, IN-
OX
2PLACO30130NO
Twin-wall bal-
anced flue el-
bow 30°, IN-
OX - BLACK
115
2PLACO15130
Twin-wall bal-
anced flue el-
bow 15°, IN-
OX
2PLACO15130NO
Twin-wall bal-
anced flue el-
bow 15°, IN-
OX - BLACK
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 87
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
116
2PLACHAR130
Vertical (roof)
termination
cap, L= 360
mm, INOX
2PLACHAR130NO
Vertical (roof)
termination
cap, L= 360
mm, INOX -
BLACK
117
2DIVS5IN200
Roof flashing
for a roof
pitch of 5°-
30°, INOX
2DIVS5IN200NO
Roof flashing
for a roof
pitch of 5°-
30°, INOX -
BLACK
117
2DIVS3IN200
Roof flashing
for a roof
pitch of 31°-
45°, INOX
2DIVS3IN200NO
Roof flashing
for a roof
pitch of 31°-
45°, INOX -
BLACK
117 2DIVRTS1
Roof tile fitting
for roof flash-
ing
117
2DIVCSOL200
Collar for roof
flashing, IN-
OX
2DIVCSOL200NO
Collar for roof
flashing, IN-
OX - BLACK
2DIVJOCO205
Sealing ring
for collar roof
flashing
Available components for the concentric flue system -
natural draught
88 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
117
2DIVS5PS200
Roof flashing,
standard
model, lead:
0,6mm thick,
for a roof
pitch of 5°-
30°, with IN-
OX cone
2DIVS5PR210
Roof flashing,
large tile mod-
el, lead:
1,0mm thick,
for a roof
pitch of 5°-
30°, with IN-
OX cone
2DIVS3PS200
Roof flashing,
standard
model, lead:
0,6mm thick,
for a roof
pitch of 31°-
45°, with IN-
OX cone
2DIVS3PR210
Roof flashing,
large tile mod-
el, lead:
1,0mm thick,
for a roof
pitch of 31°-
45°, with IN-
OX cone
117
2DIVC5LA200NO
Cone cover
for roof flash-
ing, lead, for a
roof pitch of
5°- 30°, INOX
- BLACK
2DIVC3LA200NO
Cone cover
for roof flash-
ing, lead, for a
roof pitch of
31°- 45°, IN-
OX - BLACK
118
2DIVSOIN200
Roof flashing
for existing
chimney or
flat roof, INOX
2DIVSOIN200NO
Roof flashing
for existing
chimney or
flat roof, INOX
- BLACK
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 89
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
119
2PLATHOR130
Horizontal
(wall) termina-
tion kit, with
rosettes, L=
min. 580 mm /
max. 780 mm.
INOX
2PLATHOR130NO
Horizontal
(wall) termina-
tion kit, with
rosettes, L=
min. 580 mm /
max. 780 mm.
INOX -
BLACK
120
2PLACOJO130
Locking band,
quick-fasten-
ing. INOX
2PLACOJO130NO
Locking band,
quick-fasten-
ing. INOX -
BLACK
121 2PLAJOIF130 Fiber seal
123
2PLACOMU130 Wall strap, IN-
OX
2PLACOMU130NO Wall strap, IN-
OX - BLACK
123 2PLASUPLR130
Wall support,
quick fasten-
ing
124 2PLACOCF130
Set of ceiling
finishing
plates / Fire
stops
124 2PLAPVEN130
Ceiling finish-
ing plate with
ventilation
openings
Available components for the concentric flue system -
natural draught
90 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
124
2PLAROSA130BT Rosette, IN-
OX
2PLAROSA130BTNO Rosette, IN-
OX - BLACK
2PLAROSA130BTBL Rosette, IN-
OX - WHITE
124
2PLAROSA130
Rosette with 4
mounting
holes, INOX
2PLAROSA130NO
Rosette with 4
mounting
holes, INOX -
BLACK
2PLAROSA130BL
Rosette with 4
mounting
holes, INOX -
WHITE
134
2PLAEMES130
Concentric
pipe with
gauging ori-
fice, L= 250
mm, INOX
2PLAEMES130NO
Concentric
pipe with
gauging ori-
fice, L= 250
mm, INOX -
BLACK
135 2PLAERAM130
Concentric
pipe with in-
spection/
cleaning
opening, L=
260 mm.
136 2PLACOSO130 Floor support
strap
136 2PLACTOS130 Roof strap
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 91
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
136 2PLAEPDS130
Clearance
roof/floor pas-
sage
125
2PLAADA71302020
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x200mm,
INOX
2PLAADA71302020NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x200mm,
INOX -
BLACK
●●●
125
2PLAADA71302525
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
250x250mm,
INOX
2PLAADA71302525NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
250x250mm,
INOX -
BLACK
●●●
Available components for the concentric flue system -
natural draught
92 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
125
2PLAADA71303030
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x300mm,
INOX
2PLAADA71303030NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x300mm,
INOX -
BLACK
●●●
125
2PLAADA71302040
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x400mm,
INOX
2PLAADA71302040NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
200x400mm,
INOX -
BLACK
●●●
125
2PLAADA71303040
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x400mm,
INOX
2PLAADA71303040NO
Adapter Modi-
nox PLA →
Flexible pipe,
with chimney
bottom finish-
ing plate
300x400mm,
INOX -
BLACK
●●●
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 93
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
125
2PLAADA61302020
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
200x200mm,
INOX
2PLAADA61302525
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
250x250mm,
INOX
2PLAADA61303030
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
300x300mm,
INOX
2PLAADA61302040
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
200x400mm,
INOX
2PLAADA61303040
Adapter Flexi-
ble pipe →
Modinox PLA,
with chimney
top finishing
plate
300x400mm,
INOX
2PTGKIMU130
Insulation kit
ISOMU for
wall passage
Available components for the concentric flue system -
natural draught
94 Gas Fire Front 70-75
Fig.
No. Modinox Art./ Order No. Description
Color (*) Application
stainless
steel antr. rigid flex
2PTGKIRA130 + la
pente
Insulation kit
ISORA for
pitched roof
passage
2PTGKIRAV130 + la
pente
Insulation kit
ISORA for
pitched roof
passage, roof
and floor, in-
cludes a junc-
tion collar and
4 ventilation
grilles
2PTGKIFO130
Insulation kit
FOURP for
ceiling pas-
sage. Com-
plete wood
floor kit
2PTGKIFO130BE
Insulation kit
FOURP for
ceiling pas-
sage. Com-
plete concrete
floor kit
2PTGKIFOV130
Insulation kit
FOURP for
ceiling + stor-
ey floor pas-
sage. Com-
plete wood
floor kit
2PTGKIFOVBE130
Insulation kit
FOURP for
ceiling + stor-
ey floor pas-
sage. Com-
plete concrete
floor kit
2PTGPPDR130BL
Ceiling finish-
ing plates -
White lac-
quered - Op-
tion for kit
FOURP
Available components for the concentric flue system -
natural draught
Gas Fire Front 70-75 95
Your Barbas dealer
002 - 21.07.2022 - 351792 - 235-002
41

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Barbas Gas Fire Front 70-75 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Barbas Gas Fire Front 70-75

Barbas Gas Fire Front 70-75 Zusatzinformation - Deutsch - 100 seiten

Barbas Gas Fire Front 70-75 Installationsanweisung - Deutsch - 92 seiten

Barbas Gas Fire Front 70-75 Bedienungsanleitung - Deutsch - 40 seiten

Barbas Gas Fire Front 70-75 Installationsanweisung - Englisch - 84 seiten

Barbas Gas Fire Front 70-75 Bedienungsanleitung - Englisch - 36 seiten

Barbas Gas Fire Front 70-75 Zusatzinformation - Holländisch - 100 seiten

Barbas Gas Fire Front 70-75 Installationsanweisung - Holländisch - 88 seiten

Barbas Gas Fire Front 70-75 Bedienungsanleitung - Holländisch - 36 seiten

Barbas Gas Fire Front 70-75 Zusatzinformation - Französisch - 100 seiten

Barbas Gas Fire Front 70-75 Installationsanweisung - Französisch - 88 seiten

Barbas Gas Fire Front 70-75 Bedienungsanleitung - Französisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info