GB13
The instructions below, to be carried out in the order in which they are numbered, refer to the gures (with the same step numbers) given on the last pages of
this manual.
Before starting the installation steps:
- remove the extraction panel P
- push the lever (located at the bottom of the panel) to the lef
- release the panel from the supports
- remove the grease lter
1. Remove the tape xing the control electronics box to the motor body.
Note: the drawing is only for reference, the box may be temporarily xed to other sides of the motor body.
2. Fully tighten the screws, already partially tightened, that x the electronics box to the motor body.
3. Adjust the extension of the hood support structure, as the nal height of the hood depends on this.
Note: in some cases the support structure is xed to the motor group with 1 or more screws. Check for and temporarily remove any screws to enable
adjustment of the support structure.
Fix the two sections of the structure using 16 screws (4 each corner).
Note: if required; t the reinforcement bracket into the truss and place it on the motor unit.
After installing the truss to the ceiling, x the bracket in its position.
4 Place the ceiling hole diagram directly above the cooktop (the center of the diagram must match the center of the cooktop and the edges must be parallel
to the sides of the cooktop, the side of the diagram with the wording FRONT (or with the arrows) corresponds to the control panel side).
Prepare the electrical connection.
5. Drill as shown (6 holes for 6 wall plugs) and insert the 6 plugs in the 6 drilled holes, tighten 4 screws on the outer holes shown on the drawing, leaving a
space of about 1 cm between the screw head and the ceiling.
6. Fit an exhaust pipe inside the truss and connect it to the collar of the motor compartment (* exhaust pipe and clamps are not provided).
7. For lter operation (7F), remove the fumes non-return valve "E", t the deector F on the truss and x it with 4 screws to the special bracket. Adjust the
deector according to the ue width. Finally, connect the exhaust pipe to the collar located on the deector.
8. Hook the truss on the 4 screws (see step 8).
WARNING: the side of the truss with electrical connection box corresponds to the side of the control panel with hood assembled.
9. Tighten rmly the 4 screws.
10. Insert and tighten rmly another 2 screws in the remaining free holes for secure xing.
Note - only for Extraction version: connect the upper end of the exhaust duct to the outdoor exhaust device (e.g.: hole on the ceiling).
11. Fix the reinforcement bracket (see step 3) to the truss in a position as intermediate as possible.
Carry out the electrical connection to the mains power supply, only turn on the power supply with assembly completed.
12. Fix the hood to the truss with 8 screws.
WARNING: the side of the truss with electrical connection box corresponds to the side of the control panel with hood assembled.
13. Carry out the electrical connection of control panel and the lamps.
Position the power cable in its housing and secure the cable to the cable clamp (14a).
Note: hook the excess cable to the appropriate cable glands (tted with screw for tightening).
14. Join the two top sections of the ue to cover the truss so that one of the slots on the sections is on the same side as the control panel and the other is on
the opposite side.
Screw the two sections with 8 screws (4 each side - see the plan diagram for joining the two sections).
15. Fix the top ue assembly to the truss, near the ceiling, with 2 screws (one each side).
16. Join the two bottom sections of the ue covering the truss using 6 screws (3 each side - also see the plan diagram for joining the two sections).
17. Insert the bottom section of the ue in the special seat to completely cover the motor compartment and electrical connection box.
18. Apply the 2 tabs (supplied) to cover the xing points of the bottom ue sections (IMPORTANT! THE TABS FOR THE BOTTOM FLUE ARE THE NARROWER AND
LESS DEEP ONES).
The wider and deeper tabs are those used for the top ue, and must be cut to size.
Re-t the grease lters and the perimeter extraction panel.
Turn the mains power on again at the central electrical panel and check for correct hood operation.
INSTALLATION - ASSEMBLY INSTRUCTIONS
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bauknecht DBTRI 9110 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info