GB13
The instructions below, to be carried out in the order in which they are numbered, refer to the figures (with the same step numbers) provided on the last few
pages of this manual.
IMPORTANT: The flue kit must be purchased in order to use the hood in "Extractor Version"; it must be ordered and fitted before use.
1. Mark a vertical centre line on the wall.
2. Place the drilling diagram on the wall (fixing it with adhesive tape): the vertical centre line printed on the drilling diagram must be aligned with the centre
line drawn on the wall, and the lower edge of the drilling diagram must be aligned with the lower edge of the hood.
Drill the 3 holes as shown on the drawing.
IMPORTANT: The bottom edge of the drilling diagram must have a min. distance of 40 cm (for electric hobs) or 45 cm (for gas hobs).
3. Remove the drilling template from the wall, fix the support bracket to the wall with 2 plugs and 2 screws and insert the third plug in the lowermost hole.
4. Extractor Version only - Place the flue support bracket on the wall. Drill and insert the wall plugs as shown. Fix the bracket.
5. Open the perimeter hood panel.
6. Remove the grease filter.
7. Hook the hood onto the support bracket.
8. Tighten the two adjustment screws.
9. Adjust the hood horizontally, using a level and operating on the two adjustment screws.
10. Open the perimeter panel and mark the two holes for final fixing of the hood.
11. Remove the hood from the wall.
12. Drill the holes marked previously.
13. Insert the wall plugs.
14. Reattach the hood to the wall.
15. Fix the hood to the wall using two screws and two washers.
16. Filter Version only - Fit the plastic grille over the hood air outlet hole.
17. Extractor Version only - Fit the collar onto the hood air outlet hole.
18. Fit the power cable in the special housing.
19. Secure the cable to the cable clamp.
IMPORTANT: This operation is compulsory. It will prevent accidental disconnection of the power cable.
Carry out the connection to the household electrical system.
20. Extractor Version only - Connect an exhaust pipe to the collar for the expulsion of fumes.
21. Filter Version with flues only - Fix the deflector to the flue support bracket and connect the exhaust pipe to the deflector.
22. Filter or Extractor Version with flues only - Fit the flues in the relevant seat above the hood.
23. Filter or Extractor Version with flues only - Slide the top section upwards and fix the flues with two screws as shown.
24. Filter Version only - Fit the carbon filter onto the back of the grease filter, hooking it with the two rods.
25. Fit the grease filter and close the front panel.
Check for correct hood operation, referring to the hood description and use section.
INSTALLATION - ASSEMBLY INSTRUCTIONS