Press the MENU button till S1_x or S2_x is shown in the display
S1_x and S2_x are 2 different sound programmes.
With music applied the last number will count up from 0 till 20. These are the steps of the sound programmes.
Press ENTER to confirm and save these settings.
DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the
first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are connected.
If you use a controller with 5-pin DMX connection, you will need to use a 5-pin to 3-pin adapter.
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal
(+) into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.
DMX CHANNELS
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit’s optics.
• Make sure the area below the installation place is free from unwanted persons during servicing
• Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation
• The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected
• In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
• The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
• Clean with soft cloth using normal glass cleaning fluid.
• Always dry the parts carefully.
• Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.