598330
2
Zoom out
Zoom in
Vorherige Seite
1/2
Nächste Seite
1
1
3. Functions
A. MANUAL ACTIVATION & DISACTIVATION :
Activation Please check that the doors, windows, and trunk are closed. Press once the button A of the remote .
The siren chrips once*, the system is activated.
Disactivation Press once the button A on the remote. The siren chirps twice*, the system is disactivated.
Alarm memory When disactivation, if siren bips 4 times, the system has memorized a sensor triggering.
** To get weaker chirps, press B then A. See point C.
B. PROXIMITY RFID : AUTOMATIC ACTIVATION & DISACTIVATION AT PROXIMITY
Activate PROXIMITY RFID Press & hold button A during 2 sec. untill the LED flashes 4 times and off. The LED will flash every 3 sec. to transmit the code automtically. The proximity RFID is operated.
Stop PROXIMITY RFID Press & hold button A during 2 sec. untill the LED is off. , then press button A twice, the LED will flash 3 times to show the proximity RFID is OFF.
PR
PROXIMITY RFID operation When you leave your car, at about 10 to 15 m. far from the car, the system will be automatically activated after a delay of 30 sec. (1 siren chirp). When you come back to
your car , at about 10 to 15 m., the system will be automatically disactived immediately (2 siren chirps or 4 chirps if alarm memory). During the operation of the PROXIMITY
RFID function, it is always possible to activate & disactivate the system manually.
Remark Remark : The range of the PROXIMITY RFID ca be affected following weather conditions, if you stay closed to your car (20 m.), the system may activate & disactivate automatically. Then, you can disactivate the proximity RFID function.
C. OTHER FUNCTIONS :
PANIC Press button B over 2 sec.will operate PANIC, the siren will sound during 30 seconds.
BIPS LÉGERS Press B then press A (activation/disactivation), the activation/disactivation siren chirps will be weaker.
D. DETECTIONS & ALARMS :
AI
AIR PRESSURE SENSOR The cigar lighter shape air pressure sensor calculates the air pression in the passenger cell and the truck, it triggers when there is quick modification of the air pressure (door opening,
trunk opening, window breaking-in). If a window is opened, the air pressure sensor will not work properly.
SHOCK SENSOR The shock sensor is built-in the siren. There are 8 levels of sensitivity. By default (factory preset), the shock sensor is activated on level 1 (minimum sensitivity). See adjustment on point E.
CURREN
CURRENT SENSOR The current sensor is built-in the siren. By defayult (factory preset), the current sensor is not activated. For the cars after year 2000, we advise not to activate the current sensor. The current
sensor is activated 35 sec. after the activation to let the electrical equipments to shut down. See adjustment on point E.
ALARMS For any detection, the siren sounds 3 x 30 sec. and stops. This cycle will start again at each new detection. The alarm is memorized in the system and when you disactivate, the siren will chirp 4 times
(instead 2). To stop the siren sound, press button A. Siren stops but the system is still activated, press A once more to disactivate the system.
E
E. ACTIVATION & SENSITIVITY ADJUSTMENT OF THE SHOCK & CURRENT SENSORS :
PROGRAMMATION MODE Press button A to ACTIVATE the system.
Before 8 seconds, press simultaneously buttons A & B, siren will chirp 7 times to indicate that you are in the programmation mode.
SENSORS ACTIVATION Press button B once, the siren will chirp several times to show the status of the system programmation (4 different status) :
CHIRPS STATUS SHOCK SENSOR CURRENT SENSOR
* WARNING : CURRENT SENSOR
1 1 ON OFF
It is strongly disadvised to activate the current sensor on the cars after year 2000
2 2 OFF ON*
The c ars are generally canbus multiplexed and it can create false alarms.
3 3 ON ON*
4 4 OFF OFF
The current sensor is activated 35 sec. after the system activation.
When you have chosen the mode, press button A to memorize the status.
SENSITIVITY LEVEL You can adjust the sensitivity of the shock sensors on 8 levels, follow the instructions below :
ADJUSTMENT Press button A to DISACTIVATE the system.
Before 8 seconds, press simultaneously the buttons A & B, siren chirps 5 times to show that you are in the sensitivity adjustment mode
Press button B once. The siren chirps the same times as the sensitivity level : 1 chirp = Level 1 = Minimum sensitivity
8 chirps = Level 8 = Maximum sensitivity
When you adjust the sensitivity, hit the car (hand on the window for example) to validate the sensitivity.
Press button B to increase the sensitivity level, we advise not to increase over level 5 to avoid creating false alarms.
Press button A to memorize and get out the sensitivity adjustment mode.
During adjsutments, if you do not press a button during 20 sec., system will get out the programmation mode automatically.
F. RE-CODING A COMPONENT
You can program 3 remotes and 1 cigar lighter pressure sensor on the same siren. To code a new component, follow the instructions below :
Stop the power of the siren and power it once again.
Before 8 sec., trigger the pressure sensor (blow toward the sensor, the LED flashes)
The siren chirps once to confirm the porgrammation of the 1st component
Press the button of the remotes to code Press the button of the remotes to code
The siren chirps twice for the 2nd component coded, 3 chirps for 3rd component and 4 chirps for the 4th.
The re-coding mode stops automatically 8 seconds after the porgrammatrion of the last component.
When you want to code only one component, we advise you to re-code all the components of the system to avoid losing the code of one of the components
G. BATTERY LIFE
. Air pressure sensor (cigar lighter) : 6 days in full charge
. Remotes : 18 to 24 months in regular use (manual activation & disactivation) 10 to14 months in proximity RFID (automatic activation & disactivation at proximity)
44. Assistance and guarantee
For any technical trouble, please contact our technical HOT LINE.
The BEEPER product and its accessories are guaranted during 3 years, either 36 months.The guarantee is accepted following these conditions :
The date of your purchasing will start the garantee and must be prooved by the invoice.
If you cannot provide the invoice, the date of guarantee will be the date of the manufacturing of the product + 36 months.
The guarantee is available exclusively on the product outside of all technical intervention of desinstallation and/or reinstallation or any other labour force facturation of the installator.
The freight charges of the product towards the technical service IXIT are liable to the customer, the return freight charges are liable to IXIT for mainland France only. For foreign countries, all freight charges are liable to the customer.
In order to keep the garantee, the products and its accessories musn't have been opened, analysed, modified, repaired ... by other technical services than IXIT.
The product and its accessories must have suffered a normal use and hadn't have suffered shocks, crackings, or other sign of deterioration.
The product and its accessories musn't present traces of oxydation or moisture due to water projections or to a bad protection of the system.
If the product is not defectiv If the product is not defective, the freight charges from IXIT to the customer are liable to the customer. The testing and checking time will be liable to the customer if the product is not defective.
Each invoice will be previously accepted by the consumer.
BEEPER ALARM is a registered brand of IXIT SAS
IXIT SAS
contact@ixit.fr
Parc d'activité des Grillons www.ixit.fr
228 rue de l'ancienne distillerie www.beeperalarm.com
F 69400 GLEIZÉ FRANCE www.reverse.fr
Button A
Button B
Ref : XR1
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Beeper XR1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info