8 XENYX 1202FX/1002FX User Manual
POWER
The blue POWER LED indicates that the console is powered on.
LEVEL INDICATOR
The 4-segment display accurately displays the relevant signal level.
LEVEL SETTING:
To correctly set the gains of the channels, rst set the LEVEL controls of the input
channels to their center positions. Then use the GAIN controls to increase the
input amplication until signal peaks show 0 dB on the level meter.
When recording to digital recorders, the recorders peak meter should not go into
overload. While analog recorders can be overloaded to some extent, creating only
a certain amount of distortion, digital recorders distort quickly when overloaded.
In addition, digital distortion is not only undesirable, but also renders your
recording completely useless.
When recording to an analog device, the VU meters of the recording machine
should reach approx. +3 dB with low-frequency signals (e.g. kick drum). Due to
their inertia VU meters tend to display too low a signal level at frequencies above
1 kHz. This is why, for example, a Hi-Hat should only be driven as far as -10dB.
Snaredrums should be driven to approx. 0 dB.
◊ The CLIP-LED’s of your XENYX display the level virtually independent
of frequency. A recording level of 0 dB is recommended for all
signal types.
MAIN MIX
Use the MAINMIX fader to adjust the volume of the main out.
PHONES/CONTROL ROOM
Use the PHONES/CONTROL ROOM control to adjust the signal level of the
CONTROLROOM and PHONES outputs.
CD/TAPE TO MIX
When the CD/TAPE TO MIX switch is pressed, the CD/tape input is assigned to
the main mix providing an additional input for tape machines, MIDI instruments
or other signal sources that do not require any processing.
CD/TAPE TO CTRL
Press the CD/TAPE TO CTRL switch if you want to monitor the CD/tape input via
the CTRL ROOM and PHONES outputs. A typical studio application of this function
is recording music into a digital audio workstation (DAW) with simultaneous
reproduction (see ch. 3.1).
◊ If you are recording a signal via the TAPE OUTPUT and wish to
listen to this simultaneously via the CD/TAPE INPUT, do not use the
CD/TAPE TO MIX switch. Doing this would create a feedback loop,
since the signal would be routed, via the main mix, back to tape via the
TAPE OUTPUT. To monitor the CD/TAPE INPUT, use the CD/TAPE TO CTRL
switch to assign the tape signal to the monitor(s) or headphones.
This will avoid the tape signal being routed to the TAPE OUTPUT.
FX TO CONTROL
If you want to monitor only the eects signal in your headphones or monitor
speaker(s), press the FX TO CTRL switch. Now the signal of the eects processor
can be monitored alone, and the main mix and/or CD/tape signal is no longer
present on the phone and control room outputs.
2.5 Digital eects processor
Fig. 2.5: Eects section
100 FIRST-CLASS EFFECTS
The XENYX 1202FX/1002FX features a built-in digital stereo eects processor.
Thiseects processor oers a large number of standard eects such as Hall,
Chorus, Flanger, Delay and various combination eects. Using the FX control,
youcan feed signals into the eects processor. Theintegrated eects module has
the advantage of requiring no wiring. This way, the danger of creating ground
loops or uneven signal levels is eliminated at the outset, completely simplifying
the handling.
SIGNAL and CLIP LED
The SIGNAL LED on the eects module shows the presence of a signal whose
level is high enough. This LED should always be on. However, make sure that the
clip LED lights up only sporadically. If it is lit constantly, you are overdriving the
eects processor, which leads to unpleasant distortion. If this occurs, turn the
FXcontrols down somewhat.
PROGRAM
The PROGRAM control has two functions: by turning the PROGRAM control,
you dial the number of an eect. The number of the preset you just dialed up
blinks in the display. To conrm your selection, press the PROGRAM control;
theblinkingstops.
FX TO MAIN
The FX TO MAIN control feeds the eects signal into the main mix. If the control
is turned all the way counterclockwise, no eects signal is present in the sum
signal of the mixing console.
The appendix contains an overview of all presets of the multi eects processor.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Behringer Xenyx 1002FX wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Behringer Xenyx 1002FX

Behringer Xenyx 1002FX Bedienungsanleitung - Deutsch - 14 seiten

Behringer Xenyx 1002FX Bedienungsanleitung - Holländisch - 15 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info