676964
30
Zoom out
Zoom in
Vorherige Seite
1/88
Nächste Seite
- 28 -
sent back into the room and its function is to mitigate the
unpleasant odours produced by cooking.
- The non-regenerable active carbon filters must be replaced
at least every 4 months. The saturation of the active charcoal
depends on the more or less prolonged use of the appliance,
on the type of kitchen and on the frequency with which anti-
grease filter is cleaned.
- Regenerable active charcoal filters must be washed by hand,
with non abrasive neutral detergents, or in the dishwasher at
a maximum temperature of 65°C (the washing cycle must be
complete without dishware). Remove excess water without
damaging the filter, remove the plastic parts, and let the
mat dry in the oven for at least 15 minutes approximately at
a maximum temperature of 100°C. To keep the regenerable
charcoal filter functioning efficient this operation must be
repeated every 2 months. These must be replaced at least
every 3 years or when the mat is damaged.
•Beforeremountingtheanti-greasefiltersandtheregen-
erable active charcoal filters it is important that they are
completely dry.
•Cleanthehoodfrequently,bothinternallyandexternally,
using a cloth dampened with denatured alcohol or neutral
liquid detergents that are non abrasive.
 The lighting .system is designed for use during cooking
and not for the prolonged general lighting of the room. The
prolonged use of the lighting system significantly decreases
the average duration of the bulbs.
 If the appliance is equipped with courtesy lights it is possible
to use them for general room lighting for a prolonged amount
of time.
•Attention: the non compliance with the hood cleaning
warnings and with the replacement and cleaning of the filters
entails risk of fires. One therefore recommends keeping to the
suggested instructions.
•Replacinghalogenlightbulbs(Fig.15.1):
To replace the halogen light bulbs B, remove the glass pane
C using a lever action on the relevant cracks.
Replace the bulbs with new ones of the same type.
Caution: do not touch the light bulb with bare hands.
•ReplacingLEDlamps(Fig.15.2):
If the appliance version is with LED lamps, the intervention of
a specialised technician is necessary to replace them.
•Commandsluminous(Fig.16)the key symbols are ex-
plained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes (*)
If your appliance has the INTENSIVE speed function, from
speed THREE, press key E for 2 seconds and it will be activated
for 10 minutes after which it will return to the previously set
speed. When the function is active the LED flashes.
To interrupt it before the 10 minutes have elapsed, press
key E again.
Some models allow activating this function even with speed
one and two.
By pressing key F for two seconds (with the hood switched off)
the “clean air function is activated. This function switches the
appliance on for ten minutes every hour at the first speed. As
soon as this function is activated the motor starts up at the
first speed for ten minutes. During this time key F and key
C must flash at the same time. After ten minutes the motor
switches off and the LED of key F remains switched on with
a fixed light until the motor starts up again at the first speed
after fifty minutes and keys F and C start to flash again for ten
minutes and so on. By pressing any key for the exclusion of
the hood light the hood will return immediately to its normal
functioning (e.g. if key D is pressed the clean air function is
deactivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
(*)The “AUTOMATIC STOP TIMER delays stopping of the
hood, which will continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
•Anti-grease/activecharcoalfilterssaturation:
- When the A key flashes with a 2 second frequency the anti-
grease filters must be washed.
- When the A key flashes with a 0.5 second frequency the
active carbon filters must be replaced or washed depending
on the type of filter.
Once the clean filter has been put back one must reset the
electronic memory by pressing the A key for approximately 5
seconds until it stops flashing.
•Commands(Fig.17):
Push-button A = on/off lights switch.
Push-button B = on/off cooker hood switch. The appliance
switches on at speed level 1, If the cooker hood is on depress
the push-button for 2 sec. to switch off the cooker hood. If
the cooker hood is at speed level 1 it will not be necessary
to depress the push-button to switch the cooker hood off.
Decreases the motor speed.
Display C = indicates the motor speed level selected and
activates the timer.
Push-button D = switches on the cooker hood. Increases the
motor speed. Touching the key at 3rd speed, the intensive
function runs for 10’, then the appliance go back to work at
the original speed. During this function the display blinks.
Key E = The Timer times the functions on activation for 15
minutes, after which they are switched off. The Timer is deac-
tivated by re-pressing Key E.
When the Timer is activated the decimal point must flash on
the display. The Timer cannot be activated if the intensive
speed is functioning.
The “clean air function is activated by pressing key E for 2
seconds when the appliance is switched off. This switches the
motor on for 10 minutes every hour at the first speed.
During functioning a rotary movement of the peripheral seg-
ments must be visualised on the display. When this time has
passed the motor switches off and the fixed letter C must
be visualised on the display until the motor re-starts after 50
minutes for another 10 minutes and so on.
Press any key apart from the light keys to return to normal
functioning. Press key E to deactivate the function.
•Anti-grease/activecharcoalfilterssaturation:
- When display item C flashes, at a speed where it alternates
with the letter F (e.g. 1 and F), the anti-grease filters must be
washed.
- When display item C flashes, at a speed where it alternates
with the letter A (e.g. 1 and A), the active carbon filters must
be replaced or washed depending on the type of filter.
After the clean filter has been positioned correctly, the
electronic memory must be reset by pressing button A for
approximately 5 seconds, until the indication F or A shown
on the display C stops flashing.
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für BEKO HCA91531X wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info