48
Bellfi res English
Installation instructions
Never position the appliance directly against the rear wall,
but always place an nonfl ammable insulation plate, at least
12 mm thick, between the appliance and the rear wall, with
free space on either side of 2 cm. (Total ± 5 cm.)
The rear wall must be made of nonfl ammable material.
Never use combustible materials during the installation.
Ventilate the fi replace, by allowing vents above and
below the fi replace.
During installation of the gas fi re, a clearance of 3 mm
should be maintained on all sides of the appliance to
allow for expansion of the appliance during operation.
Do not insulate the appliance! Only the top and sides
may be fi tted with a strip of white, loose insulation wool
(heat-resistant to 1000°C), width 15 cm max. to protect
the wall.
Do not use fi breglass or Rockwool, or any other sort of
insulating material. These emit a pungent odour.
This is considered extremely unpleasant. They may also
cause discolouring of the column.
Flammable materials, such as curtains, should not
be placed in the vicinity of the gas fi re.
Minimum safe distance: 100 cm.
If desired, fi t a convection package to the appliance.
(See chapter 1.1)
The appliance can be easily installed Corner Bell Medium 3 R with options:
using a set of carrying brackets • 10 cm frame (4 sided) and mantle iron
(accessory). After installing: • convection package
remove carrying brackets!