Position the two fi tting boxes in the fi replace, at a minimum distance of 30 cm under the
ceiling. Mount the other end of the aluminium pipes onto the fi tting boxes. To do this use
the hose clamps supplied. When the fi replace is completely fi nished, mount the grilles
onto the fi tting boxes.
Within a range of 30 cm either side and 50 cm above the
escape opening, there must be no fl ammable materials
(e.g. wooden ceiling, fi tted furniture).
1.7.3 Building in the appliance
Remove the front of the casing, if applicable. (See Chapter 4: Dismantling / Assembling
of the glass.)
Decide on positions of the vents (grilles above and below the fi replace) and, if
applicable, the hot air grids of the convection package.
The brickwork must be built up around the appliance. In connection with the appliance
expanding during burning: there must be at least 3 mm clearance on either side of the
appliance. Do not build up the brickwork farther than the angle irons/brackets (keep in
mind the thickness of any plastering!).
Do not use masking tape on the appliance when installing
and plastering.
Tape can damage the fi nish of the appliance.
Connect up the convection package, if applicable. See 1.7.2.1.