19
Bellfi res English
Instructions for use
Figure 4: Gas regulating block
2.4.3 Operation (Remote control)
Igniting the fi re
• Open the gas supply valve in the gas pipe to the fi re.
• Switch the hand-held transmitter to the
position.
• On the hand-held transmitter, press the OFF and
(large fl ame) buttons simultaneously. A short tone
will signal the start.
Release the buttons. Short beeps will then follow until
the pilot light and main burner are ignited.
Once the main burner has been ignited, the fl ame
height will automatically rise to the maximum position.
Important: • If the pilot fl ame goes out for any reason, wait for 5 minutes
before attempting to re-light it.
• If the pilot light does not ignite after 3 ignition attempts;
close the gas tap and warn the fi tter.
• Once the pilot light is burning, the main burner must ignite
within 10 seconds automatically.
If this does not happen, immediately close the gas tap and
warn the fi tter.
• If the main burner ignites with a pop; immediately close the
gas tap and warn the fi tter.
Motor-knob
Microswitch8-wire Receiver Jack
Pilot gas adjustment screw
(Factory set) (Puncture the casing
with a small screwdriver)
Adjustment screw
Maximum burner pressure
(Factory set and sealed)