by 3A fuse.
2. Warning!
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating.
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood.
D) Avoid free flame, as it is damaging for the filters and a
fire hazard.
E) Constantly check food frying to avoid that the over-
heated oil may become a fire hazard.
F) Disconnect the electrical plug prior to any maintenance.
G) This appliance is not intended for use by young children
or infirm persons without supervision.
H) Young children should be supervised to ensure they do
not play with the appliance.
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels.
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions.
This appliance conforms to the European Directive EC/2002/96,
Waste Electrical and Electronic Equipment (WEEE). By making
sure that this appliance is disposed of in a suitable manner, the
user is helping to prevent potential damage to the environ-
ment or to public health.
The symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to
a suitable electric and electronic appliance recycling collection
point. Follow local guidelines when disposing of waste. For
more information on the treatment, re-use and recycling of
this product, please contact your local authority, domestic
waste collection service or the shop where the appliance was
purchased.
INSTALLATION INSTRUCTIONS
•Assemblyandelectricalconnectionsmustbecarriedout
by specialised personnel.
•Wearprotectiveglovesbeforeproceedingwiththe
installation.
•ElectricConnection:
Note! Verify the data label placed inside the appliance:
- If the symbol
appears on the plate, it means that no earth
connection must be made on the appliance, therefore follow
the instructions concerning insulation class II.
- If the symbol
DOES NOT appear on the plate, follow the
instructions concerning insulation class I.
Insulation class II
- The appliance has been manufactured as a class II, therefore
no earth cable is necessary. The plug must be easily accessible
after the installation of the appliance. If the appliance is equip-
ped with power cord without plug, a suitably dimensioned
omnipolar switch with 3 mm minimum opening between con-
tacts must be fitted between the appliance and the electricity
supply in compliance with the load and current regulations.
- The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral.
Insulation class I
This is a class I, appliance and must therefore be connected to
an effiecient earthing system.
- The appliance must be connected to the electricity supply as
follows:
BROWN = L line
BLUE = N neutral
YELLOW/GREEN =
earth.
The neutral wire must be connected to the terminal with the
N symbol while the YELLOW/GREEN, wire must be connected
to the terminal by the earth symbol
.
When connecting the appliance to the electricity supply, make
sure that the mains socket has an earth connection. After fitting
the ducted cooker hood, make sure that the electrical plug is
in a position where it can be accessed easily. If the appliance
is connected directly to the electricity supply, an omnipolar
switch with a minimum contact opening of 3 mm must be
placed in between the two; its size must be suitable for the
load required and it must comply with current legislation.
 If the hob is electric, gas, or induction, the minimum distance
between the same and the lower part of the hood must be at
least 65 cm. If a connection tube composed of two parts is
used, the upper part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same con-
ductor used to circulate hot air or for evacuating fumes from
other appliances generated by other than an electrical source.
Before proceeding with the assembly operations, remove the
anti-grease filter(s) (Fig.5) so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
 We recommend the use of an air exhaust tube which has the
same diameter as the air exhaust outlet hole. If a pipe with a
smaller diameter is used, the efficiency of the product may be
reduced and its operation may become noisier.
 If your appliance has been designed for use in habitations
supplied with acentralised suction device perform the fol-
lowing operations:
- The switch controls opening and closure of a valve using
a thermoelectical device. By placing the switch in the ON
position, after a minute, the valve opens rotating 90° allowing
suction of the stale air. By placing the switch in the OFF posi-
tion, the valve closes after 100 seconds.
•Fixingtothewall:
Drill the holes A respecting the distances indicated (Fig.2). Fix
the appliance to the wall and align it in horizontal position
to the wall units. When the appliance has been adjusted,
definitely fix the hood using the screws A (Fig.4). For the
various installations use screws and screw anchors suited to
the type of wall (e.g. reinforced concrete, plasterboard, etc.). If
the screws and screw anchors are provided with the product,
check that they are suitable for the type of wall on which the
hood is to be fixed.
•Fixingthedecorativetelescopicflue:
Arrange the electrical power supply within the dimensions of
the decorative flue. If your appliance is to be installed in the
ducting version or in the version with external motor, prepare
the air exhaust opening. Adjust the width of the support bra-
cket of the upper flue (Fig.3). Then fix it to the ceiling using the
screws A (Fig.3) in such a way that it is in line with your hood
and respecting the distance from the ceiling indicated in Fig.2.
Connect the flange C to the air exhaust hole using a connection
pipe (Fig.4). Insert the upper flue into the lower flue and rest
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Belling 1000-AWBL wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info