577171
9
Zoom out
Zoom in
Vorherige Seite
1/30
Nächste Seite
09/ 2003
BENNING CC 1
7
6. Environment conditions:
- The BENNING CC 1 is intended for making measurements in dry
environment.
- Maximum barometric elevation for making measurements: 2000 m,
- Overvoltage category IEC 60664/ IEC 61010, 300 V category III,
600 V category II,
- Contamination degree II according to EN 61010-1
- Protection class: IP 30 (EN 60529),
- Operating temperature and relative humidity:
For operating temperatures from 0 °C to 30 °C: relative humidity less than 80
%
For operating temperatures from 31 °C to 40 °C: relative humidity less than 75
%
For operating temperature from 41 °C to 50 °C: relative humidity less than 45 %
- Storage temperature: The BENNING CC 1 can be stored at any temperature
in the range from 20 °C to + 60 °C ).
7. Electrical specications
Note: The measuring precision is specied as the sum of
- a relative fraction of the measured value and
- a current value in A.
The measurement precision applies at a temperature of 23 °C ± 5 °C and a
relative humidity less than 75 %.
7.1 Alternating current measurement
Measurement
range
Measured
value
Output Measurement precision
400 A
3 A 3 mV
± (1,9 % + 0,5 A)
at 50 Hz - 60 Hz
30 A 30 mV
350 A 350 mV
400 A 400 mV
± (3,2 % + 1 A)
at 50 Hz - 60 Hz
Max. equivalent source resistance: 75 Ω
8. Making measurements with the BENNING CC 1
8.1 Preparations for making measurements
Operate and store the BENNING CC 1 only at the specied storage and
operating temperatures. Avoid continuous insulation.
- The nominal voltage and current ratings of the safety measuring cables
included in the scope of delivery correspond to the ratings of the
BENNING CC 1.
- The safety measuring cable is securely connected to the BENNING CC 1
and cannot be removed.
- Check the insulation of the safety measuring cables. Discard the
BENNING CC 1 immediately if the insulation is damaged.1
- Do not clamp the measuring pliers on a live conductor before the
BENNING CC 1 has not been connected to a multimeter.
Strong sources of interference in the vicinity of the BENNING CC 1 can lead
to unstable readings and measuring errors.
- Do not apply any voltage to the output contacts of the BENNING CC 1.
Do not exceed the maximum permitted voltage with respect to
earth potential! Electrical danger!
The highest voltage, that may be applied to the BENNING CC 1 against ground
potential, is 600 V.
8.2 Alternating current measurement
- Set the multimeter to the function “alternating voltage measurement” (V AC)
and select a measurement range that can display voltages from 1 mV to
400 mV.
- Contact the 4 mm safety connector of the spiral type safety measuring cable
with the COM jack of the multimeter.
- Contact the red 4 mm safety connector of the spiral type safety measuring
cable with the voltage input jack (V) of the multimeter.
- Opening lever
Operate and use meas. pliers to
clamp the single wire
live conductor.
- Read off the voltage value on the multimeter and convert to the current
value taking into account the conversion factor.
cc_1_in.indd 24.09.2003, 10:137
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning CC1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info