DUSPOL
®
digital
7
Operating Manual
DUSPOL
®
digital
Before using the DUSPOL
®
digital voltage tester, proceed as
follows: Please read the operating manual and absolutely ob-
serve the safety instructions!
Table of Contents
1. Safety instructions
2. Device description
3. Functional test before use to ensure the absence of
voltage of an installation
4. Checking the absence of voltage of an installation
5. Load connection with vibration motor
6. External conductor test (phase indication)
7. Phase sequence test
8. Continuity test
9. Resistance measurement
10. Diode test
11. Cable break detector
12. Measuring point / display illumination
13. Battery replacement
14. Technical data
15. General maintenance
16. Environmental protection
1. Safety instructions:
- During the use, touch the tester at the isolated handles L1
8
and L2
9
only and do not touch the probe tips L1/-
2
and L2/+
3
!
- Check the voltage tester for correct functioning immedi-
ately before and after using it in order to ensure the ab-
sence of voltage of an installation (see section 3)! Do not
use the voltage tester, if one or more indications are not
working or if it does not seem to be ready for operation!
Please repeat the test with another voltage tester after-
wards.
- With the battery being exhausted, the voltage tester is not
fully functional! From a voltage of AC/DC ≥ 50 V on, volt-
age tests are also possible without batteries by means of
the LED step indicator
9
. The LC display
6
is activated
with a minimum voltage ≥ 90 V AC/DC.
- The voltage tester must be used only within the stated
nominal voltage range and in electrical installations of up
to 1,000 V AC / 1,200 V DC!
- The voltage tester must be used only in electric circuits of
overvoltage category CAT III with max. 1,000 V or over-
voltage category CAT IV with max. 600 V for phase-to-
earth measurements.
- Do not operate the device with the battery compartment
being open.
- The voltage tester is designed for being used by qualified
electricians and under safe working conditions.
- The LED step indicator
J
is intended for indicating the
voltage range. It is not intended for measuring purposes.
- Creating a voltage tester for more than 30 seconds volt-
age (maximum duty cycle = 30 s)!
- Do not dismantle the voltage tester!
- The voltage tester must be protected against contamina-
tion and damaging of the housing surface.
- To protect them against damaging, provide the probe tips
with the enclosed probe tip protector
1
after using the
voltage tester!
Electrical symbols on the device:
Symbol Meaning
Important documentation!
The symbol indicates that the guide described
in the manual, to avoid any risks
Device or equipment for working under voltage
Push-button
Alternating voltage (AC)
Direct voltage (DC)
Direct and alternating voltage (DC/AC)
Earth (voltage to ground)
Phase sequence indication; the phase se-
quence can be indicated only at 50 or 60 Hz
and in an earthed mains
This symbol shows the orientation of the batter-
ies for inserting them with correct polarity
2. Device description
1
Probe tip protector
2
Probe tip L1/-
3
Probe tip L2/+
4
LED measuring point illumination
5
Sensor of the cable break detector
6
LC display
7
Push-button
8
Handle L1
9
Display handle L2
J
LED step indicator
K
Red LED for external conductor test (phase indication)
L
Green LEDs ◄LR► of the phase sequence indication
(left/right)
M
Yellow LED Ω for continuity test (lights up)/cable break
detector (ashes)
N
Light sensor for LC display illumination
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning Duspol Digital wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info