15
5.1.17 The BENNING MM 1-1/ 1-2/ 1-3 is equipped with a detector as voltage
indicator at its top side to localize earthed AC voltages.
6. Ambient conditions
- The BENNING MM 1-1/ 1-2/ 1-3 is intended for measurements under dry
ambient conditions,
- Maximum barometric height for measurements: 2000 m,
- Overvoltage category / installation category: IEC 60664-1/ IEC 61010-1
600 V category III; 1000 V category II,
- Contamination class: 2,
- Protection category: IP 30 DIN VDE 0470-1 IEC/EN 60529
IP 30 means: Protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm, (3 – rst index).
No protection against water, (0 – second index).
- Operating temperature and relative air humidity:
For operating temperatures from 0 °C to 30 °C: relative air humidity less
than 80 %,
For operating temperatures from 31 °C to 40 °C: relative air humidity less
than 75 %,
For operating temperatures from 41 °C to 50 °C: relative air humidity less
than 45 %,
- Storage temperature: The BENNING MM 1-1/ 1-2/ 1-3 can be stored at
temperatures between - 15 °C and + 60 °C (air humidity of 0 to 80 %).
During storage, the battery should be removed.
7. Electricalspecications
Note: The measuring accuracy is specied as the sum of:
- a relative part of the measured value and
- a number of digits (i.e. counting steps of the last digit).
This measuring accuracy applies for temperatures from 18 °C to 28 °C and a
relative air humidity less than 80 %.
7.1 DC voltage ranges
The input resistance is 10 MΩ.
Measuring
range
*3
Resolution Measuring accuracy
Overload
protection
200 mV 100 µV ± (0.5 % of the measured value + 2 digits) 1000 V
DC
2 V 1 mV ± (0.5 % of the measured value + 2 digits) 1000 V
DC
20 V 10 mV ± (0.5 % of the measured value + 2 digits) 1000 V
DC
200 V 100 mV ± (0.5 % of the measured value + 2 digits) 1000 V
DC
1000 V 1 V ± (0.5 % of the measured value + 2 digits) 1000 V
DC
7.2 AC voltage ranges
The input resistance is 10 MΩ in parallel 100 pF.
Measuring
range
*3
Resolution
Measuring accuracy *
1
within the
frequency range 50 Hz - 300 Hz
Overload
protection
200 mV 100 µV ± (2.0 % of the measured value + 5 digits) *
2
750 V
eff
2 V 1 mV ± (1.5 % of the measured value + 5 digits) 750 V
eff
frequency range 50 Hz - 500 Hz
20 V 10 mV ± (1.5 % of the measured value + 5 digits) 750 V
eff
200 V 100 mV ± (1.5 % of the measured value + 5 digits) 750 V
eff
750 V 1 V ± (1.5 % of the measured value + 5 digits) 750 V
eff
The measured value of the BENNING MM 1-1/ 1-2/ 1-3 is obtained by mean
value rectication and is displayed as r.m.s. value.
*1
The measuring accuracy is specied for a sinusoidal curve. In case of non-
sinusoidal curves, the accuracy of the displayed value decreases. Thus, an
additional error results for the following crest factors:
Crest factor from 1.4 to 3.0 additional error ± 1.5 %
Crest factor from 3.0 to 4.0 additional error ± 3 %
*2
Applies to sinusoidal curves of 50 Hz/ 60 Hz
*3
For automatic range selection (AUTO), the change-over point might be al-
ready at a value of 1400!
09/ 2013
BENNING MM 1-1/ 1-2/ 1-3
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning MM 1.2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info