577341
28
Zoom out
Zoom in
Vorherige Seite
1/169
Nächste Seite
19
BENNING MM 1-1/ 1-2/ 1-3.
- Bring the safety measuring leads into contact with the measuring points. If the
lead resistance between the COM jack J and the jack for V, , , Hz 9 falls
below 25 , the integrated buzzer of the BENNING MM 1-1/ 1-2/ 1-3 sounds.
See gure 8: Continuity test with buzzer
8.6 Capacitymeasurement (BENNING MM 1-2/ 1-3)
Beforeperformingcapacitymeasurements,dischargecapaci
torscompletely!
Neverapplyvoltagetothecapacitymeasurementjacks!
Thismightdamage ordestroythedevice!A damageddevice
might represent an electrical hazard!
- Select the desired function ( ) by means of the rotary switch 8 of the
BENNING MM 1-2/ 1-3.
- Determine the polarity of the capacitor and completely discharge the ca-
pacitor.
- Connect the black safety measuring lead to the COM jack J of the
BENNING MM 1-2/ 1-3.
- Connect the red safety measuring lead to the jack for V, , , Hz 9 of the
BENNING MM 1-2/ 1-3.
- Bring the safety measuring leads into contact with the discharged capacitor
according to ist polarity and read the measured value on the digital display
of the BENNING MM 1-2/ 1-3.
See gure 9: Capacity measurement
8.7 Frequencymeasurement (BENNING MM 1-2/ 1-3)
- Select the desired function (Hz) by means of the rotary switch 8 of the
BENNING MM 1-2/ 1-3.
- Connect the black safety measuring lead to the COM jack J of the
BENNING MM 1-2/ 1-3.
- Connect the red safety measuring lead to the jack for V, , , Hz 9 of
the BENNING MM 1-2/ 1-3. Please observe the minimum sensitivity for fre-
quency measurements of the BENNING MM 1-2/ 1-3!
- Bring the safety measuring leads into contact with the measuring
points and read the measured value on the digital display of the
BENNING MM 1-2/ 1-3.
See gure 10: Frequency measurement
8.8 Temperature measurement (BENNING MM 1-3)
- Select the desired function (°C or °F) by means of the rotary switch 8 of the
BENNING MM 1-3.
- Connect the temperature measuring adapter and the temperature meas-
uring lead to the COM jack (-) J and to the jack for V, , , Hz (+) 9
observing correct polarity.
- Arrange the end of the temperature measuring lead in the vicinity of the heat
source to be monitored. Read the measured value on the digital display
of the BENNING MM 1-3.
See gure 11: Temperature measurement
8.9 Voltage indicator
The voltage indicator function is possible from each position of the rotary switch.
No measuring leads are required as voltage indicator (non-contact detection
of an alternating eld). The detector is located on the upper part of the device
behind the LED. By pressing the „VoltSensor“ key 5, the display indication dis-
appears (if the display is switched on). If a phase voltage is localized, this is
indicated by an acoustic signal and a red LED signal M. An indication is made in
earthed AC current networks only! The phase can be determined by means of a
single-pole measuring lead.
Practical hint:
Interruptions (cable breaks) in cables lying around openly such as e.g. cable
reels, fairy lights etc. can be traced from the feeding point (phase) to the point
of interruption.
Functional range: 230 V
See gure 12: Voltage indicator with buzzer
8.9.1 Phase test
- Connect the red safety measuring lead to the jack for V, , , Hz 9 of the
BENNING MM 1-1/ 1-2/ 1-3.
- Bring the safety measuring lead into contact with the measuring point of the
system part and press the „VoltSensor“ key 5.
- If the red LED lights and if there is an acoustic signal, the phase of an
earthed AC voltage is applied to this measuring point (system part).
09/ 2013
BENNING MM 1-1/ 1-2/ 1-3
28

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning MM 1.2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info