Automatic measurement (Vo/c, Is/c, R
ISO
)
Attention:
Maximum DC power: P ≤ 10 kW, Vo/c ≤ 1000 V, Is/c ≤ 15 A
Do not make measurements at PV strings which are connected in parallel!
1. Connect the BENNING PV 1-1 to the PV generator as shown, by means of
the enclosed PV safety measuring leads and the red 4 mm safety test lead.
2. The open-circuit voltage (Vo/c) is automatically displayed.
3. In case of reversed polarity of the DC voltage, the symbol is displayed and
the measurement will be blocked.
4. Use the
V
ISO
-key to select 250 V, 500 V or 1000 V insulation test voltage.
5. Press the
Auto
-key to automatically measure short-circuit current (I
S/C
) and
insulation resistance (R
ISO
).
Note:
The red 4 mm safety measuring lead is required for the insulation resistance
measurement.
500V
250V 1000V
PV 1-1
DIN EN 62446 (VDE 0126-23), ÖVE/ÖNORM EN 62446
Auto
Ω
NULL
R
PE
V
ISO
ON/OFF
press 2 sec.
NULL
red redblack
Null balance of the measuring leads, resistance (R
PE
)
1. Connect the safety measuring leads to the red and black 4 mm test sockets of
the BENNING PV 1-1.
2. Hold the test probe tips together or connect together using the supplied
crocodile clips.
3. Press and hold the
Ω
NULL
-key until an acoustic signal sounds and the
Ω
NULL
-symbol
is displayed.
4. The Null-value is stored when unit is switched off.
5. To disable, press
Ω
NULL
-key until the
Ω
NULL
-symbol is removed from LC display.
Note:
Max. measuring lead resistance: 10 Ohm
500V
250V 1000V
PV 1-1
DIN EN 62446 (VDE 0126-23), ÖVE/ÖNORM EN 62446
Auto
Ω
NULL
R
PE
V
ISO
ON/OFF
press 2 sec.
NULL
red black
Protective conductor resistance (R
PE
)
1. Connect the 4 mm safety measuring leads as shown.
2. To make a single measurement (2 sec.), press and release the
R
PE
-
key.
3.
To make a continuous measurement, press and hold the
R
PE
-key until the symbol
is displayed continuously.
4. Press the
R
PE
-
key to terminate the continuous measurement.
500V
250V 1000V
PV 1-1
DIN EN 62446 (VDE 0126-23), ÖVE/ÖNORM EN 62446
Auto
Ω
NULL
R
PE
V
ISO
ON/OFF
press 2 sec.
NULL
R
PE
red
black
AC/DC current measurement
1. Disconnect all safety measuring leads from the BENNING PV 1-1.
2. Connect the BENNING CC 3 (option) current clamp adapter to the 4 mm test
sockets.
3. Select the 40 A range on the BENNING CC 3.
4. Press the null balance key (ZERO) of the BENNING CC 3 for approx. 2
seconds.
5. Press the
V
ISO
-key on the BENNING PV 1-1 until the symbol is
displayed.
6. The AC/DC current can be measured in single-wire live conductor.
500V
250V 1000V
PV 1-1
DIN EN 62446 (VDE 0126-23), ÖVE/ÖNORM EN 62446
Auto
Ω
NULL
R
PE
V
ISO
ON/OFF
press 2 sec.
+
40A : 10mV/A
300A : 1mV/A
BATT
LOW
PWR
ON
BENNING CC 3
ZERO A
OFF
40A
300A
CAT. III 600V
300A
NULL
AC/DC voltage measurement
1. Disconnect the PV safety measuring leads from the BENNING PV 1-1.
2. Connect the red and black safety measuring lead as pictured.
3. The BENNING PV 1-1 automatically measures the AC/DC voltage at the
measuring probes.
4. The polarity of the DC voltage is displayed by “+/-“. In case of AC voltage,
“+/-“ will be displayed alternately.
500V
250V 1000V
PV 1-1
DIN EN 62446 (VDE 0126-23), ÖVE/ÖNORM EN 62446
Auto
Ω
NULL
R
PE
V
ISO
ON/OFF
press 2 sec.
NULL
c
Max.
P ≤ 10 kW
Vo/c ≤ 1000 V
Is/c ≤ 15 A
Max.
CAT III 400 V
Option:
40 m measuring leads
BENNING TA 5
part no. 044039
Option:
BENNING CC 3
part no. 044038
PV-module/ -string
PV-module/ -string
09/ 2012
BENNING PV 1-1
309/ 2012
BENNING PV 1-1
2 09/ 2012
BENNING PV 1-1
4
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

benning-pv-1.1

Suche zurücksetzen

  • Was ist der Grund für eine zusätzliche DC Spannungsanzeige bei der Auto Messung, an der Stelle wo sonst R PE angezeigt wird und die für die Auto Messung eigentlich nicht relevant ist? Eingereicht am 14-12-2022 19:53

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning PV 1.1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Benning PV 1.1

Benning PV 1.1 Bedienungsanleitung - Deutsch, Englisch - 29 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info