BENNING ST 725
31
permanent measurements at a high load current. If the admissible internal operating
temperature is exceeded, the "StOP" and "hot" symbols will be shown on the display. In this
case, the BENNING ST 725 must be disconnected from the mains and can be used again
after a sufficient cooling phase.
Note on measuring the contact current:
- Accessible conductive parts which are not connected with the protective conductor have to
be tested as described in section 9.2. For measuring the contact current (direct measurement
method), the BENNING ST 725 has to be operated with a mains voltage of 230 V.
- During contact current measurement by means of the direct measurement method, no part
of the test object must have a connection to the earth potential. The test object must be
placed onto an insulated surface. Otherwise, leakage currents to earth might influence the
measuring result.
9.2 Testing of devices of protection class II
(shock-proof) and of devices of protection
class III
(safety extra-low voltage)
Testing of devices without protective conductor and with accessible conductive parts
- Connect the test object to the test socket
1
of the BENNING ST 725.
- Establish a connection between the 4 mm test socket
9
and a metal part of the test object
by means of the test lead with alligator clip.
- For mains operating mode (contact current by means of the direct measurement method,
test object in operation!): Connect the plug of the mains connection cable with the socket K
and the shock-proof plug with a protected shock-proof socket (230 V, 50 Hz, 16 A).
- If necessary, the testing voltage of the R
ISO
(insulating resistance) measurement can be
reduced to 250 V
DC
by means of the -key
5
. The selected testing voltage is briefly shown
on the display
8
. Press the key again to switch back to the preset testing voltage of 500 V
DC
.
- Switch the test object on.
- Press the
-key
3
to start the automatic testing procedure.
- If "Lo LOAD" is shown on the display, please check whether the test object is switched on.
- Press the key
3
to continue the testing procedure in case of the load being too low (R
L-N
>
6kΩ).
- If "HIGH LOAD“ is shown on the display, this indicates an excessive load (R
L-N
<<14Ω,I
LAST
(I
LOAD
) > 16 A) of the test object. There might be danger of a m short-circuit or of an earth
fault. Check whether there is a short-circuit between the external conductor (L) and neutral
conductor (N) of the test object.
- If there is no short-circuit, you can continue with the testing procedure by pressing the
-key
3
.
- If the insulating resistance R
ISO
is higher than the admissible limiting value, a appears
next to the R
ISO
symbol.
BENNING ST 725 in mains operating mode:
- The BENNING ST 725 interrupts the testing procedure after the R
ISO
(insulating resistance)
measurement and requests the user to switch the mains voltage of 230 V to the test socket
1
by showing a flashing "I
LEAK
" symbol. Make sure that the test sample is protected and
press the -key
4
to measure the contact current I
LEAK
(direct measurement method).
- The contact current by means of the direct measurement method only starts as soon as the
mains voltage is correct applied.
40

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning ST 725 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info