605208
5
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
5
considered when undertaking any installation. Failure to install the appliance
correctly will render the warranty null and void.
Range cookers are heavy and should be handled by two people. Never lift or drag a
range by the oven handles as damage may occur.
Note: Pictures and graphics in this manual cover different models and may vary in
minor details from your cooker.
INSTALLING RANGE COOKER
Rating of Services The rating plate is visible in the storage area of the cooker and a copy is also
attached to page two of the user manual.
Before connecting the cooker, check that the requirements on the rating plate
correspond with those of the electrical system and gas supply (where applicable).
Ensure that the electrical system and isolating switches have a suitable capacity to
carry the maximum power as indicated on the rating plate.This chart can be used as
a guide to the electrical supply ratings.
Table N°1
Cooker model Type
MCB size for dedicated
cooker circuit
The cable of
alimentation
60 cm single oven Gas hob top 13 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
*60 cm single oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
60 cm single gas oven Gas hob top 13 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
90 cm single hybrid oven Gas hob top 16 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
90 cm single gas oven Gas hob top 13 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
90 cm single oven Gas hob top 16 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
*90 cm single oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
90 cm twin oven Gas hob top 20 AMP MCB
H05BB-F or H05SS-F
3X2,5
mm²
*90 cm twin oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
100 cm twin oven Gas hob top 20 AMP MCB
H05BB-F or H05SS-F
3X2,5
mm²
*100 cm twin oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
100 cm XG (3 oven compartments) Gas hob top 32 AMP MCB
H07RN-F 3X4
mm²
*100 cm XG (3 oven compartments) Induction hob top 40 AMP MCB
H07RN-F 3X6
mm²
120cm twin oven Gas hob top + griddle 32 AMP MCB
H07RN-F 3X4
mm²
* With diversity factor applied
Positioning The cooker may be installed in a kitchen or open-plan kitchen diner but not in a
room containing a bath or shower. The cooker should be positioned in an area with
good light and free from draughts.
Any shelf or unit of combustible material should be at least 660mm above the
hotplate. In addition an area of 75mm wide on either side and behind the hotplate
must be clear of any combustible materials to a height of 400mm. Units must not
overhang over the hob.
Kitchen cabinets may be fitted flush to the sides of the cooker, but to allow for
cleaning and servicing
It is recommended that a 2.5mm gap be allowed on each side so that the cooker
may be moved if necessary.
The worktop or kitchen cabinets must not protrude beyond the height of the cooker
hotplate frame.
Ventilation Your appliance is not connected to a combustion products evacuation device. Th
e room in which it is to be installed must have an air supply in accordance with
national standards. The room must have an opening window or equivalent, and
some rooms may require a permanent vent in addition to the opening window.
General guidelines: The cooker must not be installed in a bedsit room of 20m³
or
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bertazzoni HERITAGE serie wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bertazzoni HERITAGE serie

Bertazzoni HERITAGE serie Bedienungsanleitung und Installationsanweisung - Holländisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info