707277
11
Zoom out
Zoom in
Vorherige Seite
1/68
Nächste Seite
11
3. Important Information
ATTENTION:
Proper use
Only use this device for the purpose for which it was developed and in the manner specified in the In-
structions for Use. Any improper use can be hazardous.
If you wear jewellery or piercings (e.g. navel piercing) make sure that you take it of before using the de-
vice. Otherwise it may cause punctual burnings.
Do not use this device simultaneously with other devices which give electrical pulses to your body (e.g.
TENS devices).
The device is only for private use and is not intended for medical or commercial purposes.
The manufacturer assumes no liability for damages caused through improper or wrong use.
If you are in any doubt, do not use and contact your dealer or a specified customer service address.
Only use the device with the accessory parts supplied.
Note: In rare instances skin irritation in the region of the electrodes may occur.
Improper use
The device must not be used:
On the head: here it can cause seizures.
On the neck / carotid artery: here it can cause cardiac arrest.
On the pharynx and larynx: here it can cause muscle spasms, which lead to suffocation.
Near the ribcage: Here it can increase the risk of ventricular fibrillation and lead to car-
diac arrest.
Keep the device away from children to prevent any hazards.
This device may be used by children over the age of 8 and by people with reduced physical, sensory
or mental skills or a lack of experience or knowledge, provided that they are supervised or have been
instructed on how to use the device safely, and are fully aware of the consequent risks of use. Children
must not play with the device. Cleaning and user maintenance must not be performed by children un-
less supervised.
Keep the device away from heat sources.
Do not use the device near (less than 1 m away from) shortwave or microwave devices (such as mobile
phones) as these could influence the effect.
Never use the device while you bathe or shower. Do not store or keep the device in places from which it
can fall into a bathtub or washbasin.
Never submerge the device in water or other liquids.
Damage
Check the device at regular intervals for signs of wear or damage. If you find such signs or if the device
was used improperly, you must bring it to the manufacturer or dealer before it is used again.
Switch off the device immediately if it is defective or if it malfunctions.
Only have repairs carried out by the customer service department or an authorized dealer.
Do not, under any circumstances, attempt to repair the device by yourself!
Caution - For your safety !
The device is only designed for use by healthy adults.
The device should never be used in the following cases.
users with medical implants (e.g. cardiac pacemaker)
if there are any metal implants
Cardiac arrhythmias
Acute illness
― Epilepsy
In malignant diseases
In the region of skin injuries and cuts
― Pregnancy
When there is an increased tendency to bleed, e.g. after an acute injury or a fracture. The stimulation
current can trigger or exacerbate bleeding.
After operations when muscle contractions could impair the healing process
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Beurer EM 37 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info