470375
26
Zoom out
Zoom in
Vorherige Seite
1/28
Nächste Seite
26
Select the pulse intensity which is the most comfortable for you by pressing
the key CH 1+/CH 2+.
The pulse intensity display adapts accordingly.
i
Note: Your individualised programme settings are stored and automati-
cally retrieved when you select it next.
7.4 Changes to the settings
Changing intensity (during application)
CH1+/- and CH2+/-: Changing the intensity for each channel.
DOWN key : the intensity of both channels is reduced.
Interrupting stimulation
Press the ON/OFF button.
If you press it again, the application is resumed.
Switching off a complete channel
Press the CH- key until the channel reaches the lowest intensity, then hold
the key depressed until the channel no longer appears in the display.
Hold down the corresponding key CH+ to reactivate the channel.
Changing application (completely or single parameters)
ON/OFF: to interrupt stimulation
MENU: back to program selection window or main menu
Set required parameters. Confirm with ENTER. Press ON/OFF to continue
application.
7.5 Doctor’s Function
Doctor’s Function is a specific setting to allow you to call up your specific
personal programme even more easily.
Your individual programme setting is immediately retrieved in wait status
when you switch on and is activated by simply pressing the ON/OFF key.
Settings for this individual programme may, for example, be on the advice of
your doctor.
With the Doctor’s Function, only pulse intensity can be changed during
stimulation treatment. All other parameters and programmes of the Digital
TENS/EMS are blocked in this case and cannot be modified or called up.
Setting the Doctor’s Function:
Select your programme and appropriate settings as described under 7.2
or 7.3.
Before you activate the programme by pressing the ON/OFF key, hold ON/
OFF and CH 2+ keys down simultaneously for approximately 5 seconds.
Storage in Doctor's Function is confirmed by a long signal tone.
Cancelling Doctor’s Function:
To clear the device again and access other programmes, hold down the two
keys ON/OFF and CH 2+ once again for approximately 5 seconds (not pos-
sible during stimulation). Cancelling of the Doctor’s Function is confirmed by
a long signal tone.
8. Cleaning and storage
Adhesive electrodes:
In order to ensure that the electrodes adhere for as long as possible, they
should be cleaned carefully with a damp, lint-free cloth.
After use, stick the electrodes onto the backing film.
Cleaning the unit:
Remove the batteries from the device every time you clean.
Clean the unit after use with a soft, slightly moistened cloth. In case of
more extreme soiling you can also moisten the cloth with mild soapy
water.
Ensure that no water penetrates into the machine. If this should ever hap-
pen, only use the machine again once it is completely dry.
Do not use any chemical cleaners or abrasive agents for cleaning.
Storage:
Remove the batteries from the unit if you are not going to use it for a
longer period. Leaking batteries can damage the unit.
Do not make any sharp kinks in the connecting leads or electrodes.
Detach the connecting cable from the electrodes.
After use, stick the electrodes onto the backing film.
Store the machine in a cool, well-ventilated place.
Never place any heavy objects on the machine.
9. Disposal
Used, fully discharged batteries must be disposed of in a specially labeled
collection container, at toxic waste collection points or through an electrical
retailer. You are under legal obligation to dispose of batteries correctly.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

beurer-em-40

Suche zurücksetzen

  • zum Sprunggelenk z.b. nur links : schmerzen o b e n spez. beim Ruhen.

    die abb 10 liegT über dem KNöcheln und bei 2 Füßen : ; KONNTE man nicht 1 A über Knöchel und 2 B auf den Vorderfuß plazieren ??
    und überhaupt : kann man rein technisch gesehen ,nur mt einem Kanal z.b. nur kinken Fuß arbeiten ?

    über Ihren Bericht würde ich mch freuen.

    mit Güßen h. ochsenkiel
    Abb. 10 Eingereicht am 15-2-2021 18:07

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Beurer EM 40 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info