6.4 MASSAGE programmes
Prog. no. Massage form
1 Tap and grasp massage
2 Knead and grasp massage
3 Tap massage
4 Side of hand/pressing massage
5 Side of hand/pressing massage
6 Vibratory massage
7 Tap massage (switch between electrodes)
8 Massage jet (switch between electrodes)
9 Pressure massage jet (switch between electrodes)
10 Combination programme (switch between electrodes)
Electrodes must be placed so that they surround the muscle segments in
question. For optimal effect, electrode distance must not be greater than
approx. 15 cm.
The electrodes should not be applied to the anterior wall of the
thorax, i.e. never massage the left or right large pectoral muscle.
6.5 Information on placing the electrodes
For the desired success of any stimulation application, it is important that
electrodes are placed sensibly.
We advise you to coordinate with your doctor regarding the best electrode
positions for your intended field of application.
The electrode positions suggested inside the cover (Figs. 1– 28) serve as a
guide. The following applies when choosing electrode positions:
Electrode distance
The greater the electrode distance which is selected, the greater will be the
volume of tissue that is stimulated. This applies to the area and the depth of
the tissue volume. At the same time, however, the strength of tissue stimula-
tion decreases as the electrode distance becomes greater, which means
that, if a greater electrode distance is chosen, a greater volume is stimulated,
but stimulation is weaker. To increase stimulation, pulse intensity must then
be increased.
The following guideline holds when selecting electrode distances:
most reasonable distance: approx. 5 –15 cm
below 5 cm, it is mainly surface structures which are strongly stimulated
over 15 cm, large-area and deep structures are stimulated very weakly
Electrode relationship to muscle fibre orientation
Choice of current flow direction must be adapted to the muscle fibre orien-
tation according to the desired muscle layer. If surface muscles are to be
reached, the electrodes must be placed parallel to the fibre orientation (P. 2,
Fig. 16; 1A-1B/2A-2B). If deep tissue layers are to be reached, the electrodes
must be placed crosswise to the fibre orientation (P. 2, Fig. 16; 1A-2A/1B-
2B). The latter arrangement can, for example, be achieved via the cross
electrode arrangement, such as P. 2, Fig. 16; 1A-2B/2A-1B.
Channel allocation:
Channel 1 (CH1): connection left, intensity controller rocker switch left, pulse
intensity display left (CH1).
Channel 2 (CH2): connection right, intensity controller rocker switch right,
pulse intensity display right (CH2).
i
In the treatment of pain (TENS) using the Digital TENS/EMS machine
with its 2 separately controllable channels and in each case 2 adhesive elec-
trodes, it is advisable to either position the electrodes of one channel so that
the pain spot lies between the electrodes or else you position one electrode
directly on the pain spot and the other at least 2 3 cm away.
The electrodes of the second channel can be used to treat other pain spots
simultaneously or else, however, together with the electrodes of the first
channel, to surround the pain area (opposite). A cross arrangement is again
advisable here.
i
Massage function tip: always use all 4 electrodes to ensure optimal
treatment.
i
In order to extend the durability of the electrodes, use them on clean skin
which is as free as possible from hair and grease. If necessary, clean the skin
with water before application and remove the hair.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

beurer-em-41

Suche zurücksetzen

  • Guten Tag,
    ich bin Vorsitzender eines Deutsch-Philippinichen Verein!
    Wir helfen vor Ort den Ärmsten der Armen und schicken auch Hilfgüter!
    Bei einer letzten Spende haben wir auch das Gerät EM 41 bekommen!
    Leider fehlen die E-Kabels.
    Gibt es die Anleitung auch auf englisch?
    Wir bezahlen natürlich was wir bestellen.
    Mit freundlichen Grüßen

    Lutz Ruhloff
    New Filipino – German Associations e.V.
    46145 Oberhausen, Reinersstraße 1
    Telefon 0208 62945285 / Handy 01782589265
    Email : lutz-ruloff@t-online.de


    Eingereicht am 24-9-2023 10:41

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Beurer EM 41 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Beurer EM 41

Beurer EM 41 Bedienungsanleitung - Holländisch, Dänisch, Portugiesisch, Schwedisch, Norwegisch, Finnisch - 148 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info