674370
5
Zoom out
Zoom in
Vorherige Seite
1/8
Nächste Seite
4 PB
Control Panel
ON /
Low Mist
Standby
Control
Knob
High
Max Mist
Indicator Light:
Red: Low Water
Green: Normal
1. Rotate the control knob clockwise from the off
position to the position between Low
& High
mist range to start the humidifier.
The indicator light will illuminate in green,
and mist will disperse from top after a few
seconds. See below the control panel figure
for reference.
2. Adjust the control knob to select desired
mist output level. Rotate knob clockwise
to increase mist output level and counter
clockwise to decrease mist level.
NOTE: High setting will produce the maximum
moisture level and Low setting will produce
the longest run time and quieter performance.
When the humidifier runs out of water, the
transducer and fan will automatically shut off.
3. To stop mist output at any setting, turn the
knob counter clockwise to the off position .
4. When the humidifier runs out of water, the
transducer and fan will automatically shut
off. The indicator light will turn red. Turn the
humidifier off and unplug it from the electrical
outlet.
Before refilling, empty any residual water
from the base and the tank (follow the "Daily
Maintenance" instructions). Then follow the
Filling Water Tank Instructions to refill the
tank and put back into the humidifier to begin
operation.
WARNING: DO NOT move the humidifier with
water in the tank or the humidifier base. The
moving action of the water may activate the
water tank’s release nozzle and overfill the
humidifier base. This may cause the humidifier
to function intermittently, or stop emitting mist.
If this occurs, simply remove the excess water
from the humidifier base.
LED Night Light
Your humidifier is equipped with blue decorative
night light feature. The light is built in the
humidifier base and below the water tank base,
it can illuminate the water with blue light been
seen from the water level view window. The
decorative light will turn on when the control
knob rotates clockwise into Low to High mist
position, and turns off when the control knob is
placed into Standby position.
NOTE: DO NOT operate the humidifier without
water.
Hygrometer/Thermometer
The Hygrometer/Thermometer included with
your Humidifier operates within the following
specifications:
• MeasuringTemperatureRange:-50°C~
+70°C(-50°F~+158°F)
• TemperatureAccuracy:±1°C(±2°F)
• Selectable°Cor°FDisplay
• TemperatureDisplayResolution:0.1°C
(0.2°F)
• MeasuringHumidityRange:10%Rh~
99%Rh
• HumidityAccuracy:±5%
1. Press MIN/MAX key to display the minimum
indoor temperature and minimum indoor
humidity.
2. Press MIN/MAX key again to display the
maximum indoor temperature and maximum
indoor humidity.
3. Clear button (
) to reset stored MIN/MAX
values.
4. Unit will show a Happy Face - Comfort ( )
when the humidity level is between 40-60%, a
Sad Face - Dry ( ) when humidity is below
40%, and a Neutral Face - Wet ( ) for any
humidity level above 60%.
CLEANING AND MAINTENANCE
INSTRUCTION
Humidifiers provide comfort by adding moisture
to dry, heated indoor air. To get the most benefit
from the humidifier and to avoid product misuse,
follow all instructions carefully, specifically the
operation, care and maintenance guidelines.
Please note this is an electrical appliance and
requires attention when in use.
Cleaning your humidifier every one or two
weeks, depending on the water conditions is
important in order to maintain efficient, healthy,
odour-free operation. Water quality varies widely
and, combined with build-up of mineral scale in
your humidifier, may under certain conditions
promote the growth of micro-organisms in the
water tank.
Before cleaning, Please note the
following:
•DONOTusesoap,detergents,abrasives,
gasoline, glass or furniture polish, or boiling
water to clean any part of your Ultrasonic
Humidifier. These will interfere with the
proper operation of your unit and may affect
its appearance.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bionaire BU6000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info