If the Reset Light ( ) is still on at this point, and
the unit does not being to produce moisture
within a few minutes, then please repeat steps
1-5.
IMPORTANT:
If you do not plan to use the humidifier for two or
more days, make sure any residual water is
drained from the water tank and base to prevent
algae or bacteria growth.
Cleaning and Maintenance Instruction
The following maintenance procedures must be
routinely followed in order to ensure proper,
efficient operation of your humidifier. The unit
WILL FAIL if it is not cleaned properly.
Regular cleaning prevents scale build-up on the
heating element and tray. It also prevents
microorganisms from growing on the tray and
tank. This ensures that maximum efficiency will
be achieved.
We cannot over-emphasize how essential
proper cleaning is to the maintenance and
continued use of your unit and the avoidance of
algae or bacteria build-up.
Regular Maintenance
The frequency of maintenance will depend on
the average daily use of your humidifier and the
water hardness of your area. It is recommended
that this procedure is carried out weekly or more
regularly if necessary.
1. Before cleaning, set the control to Off
(
) position and unplug the unit from the
electrical outlet.
2. Remove the water tank (A) then unlock the
misting chamber (B) by rotating the safety
lock. Lift mist chamber from the unit’s base.
3. Empty water and minerals from the base and
wash it through to remove any sediment and
dirt that has accumulated in the base.
NOTE: It is imperative that the base is cleaned
properly. The base is dishwasher safe for easy
cleaning (Top rack of the dishwasher only).
4. Rinse out the tank out and re ll with clean
cool water.
5. Wipe the heating element clean with a soft
cloth after it has had a chance to cool.
WARNING: If the misting chamber is
left assembled to the humidi er, it may
take up to an hour before the heating
element is suf ciently cool to be
touched.
This humidifier heats the water producing a
clean moisture. Some of the impurities from the
water are collected in the Heating Chamber. The
Electronic Thermal Control Heating element is
lined with a coating that is designed to provide
the easiest cleaning to prolong the operating
efficiency of the humidifier.
DO NOT use any metal or hard objects to clean
the Heating Element. The coating can be
scratched if cleaned improperly.
Never use detergents, gasoline, kerosene, glass
cleaner, furniture polish, paint thinner or other
household solvents to clean any part of the
humidifier.
De-scaling Maintenance
Scale needs to be removed as it becomes
noticeable.
1. Repeat steps 1-3 in the Maintenance
section.
2. Clean the base by partially lling the tray
with 200ml of undiluted white vinegar. If the
element is heavily scaled, plug the humidi er
into an electrical socket and turn it ON for no
longer than 15 seconds. After this time turn
the humidi er OFF and unplug it from the
electrical outlet.
Let solution stand 20 minutes, cleaning all
interior surfaces with a soft brush. Dampen
a cloth with undiluted white vinegar and wipe
out entire tray to remove scale.
3. Rinse with clean warm water to remove
scale and the white vinegar solution before
beginning to disinfect the tank.
4. Wipe the heating element clean with a soft
cloth after it has had a chance to cool.
Disinfect tank:
1. Fill tank with 1/2 teaspoon of bleach and 2
litres of water.
2. Let the solution stand for 20 minutes,
swishing every few minutes. Wet all
surfaces.
3. Empty the tank after 20 minutes, and rinse
well with water until the bleach smell is gone.
Dry with some paper towel.
4. Re ll the water tank with cool water;
replace the water tank. Repeat Operating
Instructions.
Storage Instructions
If your humidifier will not be in use for two days
or more, or at the end of the season follow these
instructions.
1. Clean, rinse and thoroughly dry the
humidi er as directed in the De-scaling
Maintenance section. DO NOT leave any
water inside the base or tank.
2. Remove the reservoir cap on the tank. Do
not store with the reservoir cap in place.
3. Place the humidi er in the original carton
and store in a cool, dry place.
4. Clean the humidi er before the next season
begins.
SERVICE INSTRUCTIONS
1. Do NOT attempt to repair or adjust any
electrical or mechanical functions on
this unit. Doing so will void the warranty.
The insides of the unit contain no user
serviceable parts. Only quali ed personnel
should perform all servicing.
2. Should the unit stop working, rst check
the fuse in the plug (UK only) or fuse/circuit
breaker at the distribution board is operating,
before contacting the manufacturer or
service agent.
3. If you need to exchange the unit, please
return it in its original carton, with a sales
receipt, to the store where you purchased it.
4. Should your humidi er require service,
please contact your local dealer.
ACCESSORIES FOR MODEL
We recommend the use of a Bionaire
TM
Hygrometer/Thermometer, model no: BT400,
to read the indoor room temperature and
humidity level.
TECHNICAL SPECIFICATIONS
Input voltage: 220-240 V~ 50 Hz
Power consumption: 400 Watts
Holmes Products (Europe) Ltd. reserves the
right to change or modify any specifications
without notice.
FOR U.K. AND IRELAND ONLY
If the plug is not suitable for the socket outlets in
your home:
Please do not attempt to remove plug and
replace. This plug is sealed and you cannot
gain access to the wires.
In the unlikely event the plug fails, please
check fuse and replace with a 3A fuse which
needs to be BSI or ASTA approved to the
BS13623 standard.
If you still have problem, please contact the UK
Customer Service helpline on 0800 052 3615.
4 5
TROUBLESHOOTING
TROUBLE PROBABLE CAUSE SOLUTION
Unit does not
turn on.
Not plugged in.
Outlet not functioning.
Plug in unit.
Have outlet replaced by a licensed
electrician.
• Re ll/
Reset light
illuminated.
Water Tank Empty.
Unit not reset after re ll.
Scale buildup on heating element.
Re ll Tank.
Follow manual for Reset Instructions.
Remove scale from heating element.
• Mist output
minimal to
none.
Scale buildup on heating element.
Humidi er is not warmed up yet.
Remove scale from heating element
.
Allow 10 minutes for the humidi er
to warm up.
• Water Leaks
from tank.
Tank rubber ring is missing.
Cap not tight enough.
Tank water is Hot.
Remove tank cap and replace or
reposition ring.
Tighten the cap.
Fill with cool water only.
• Crack in Tank.
Hot water will cause tank to
pressurize.
Tanks will crack if hit or
dropped.
Fill with cool water only.
Handle tank with Care.
Film on tank.
Mineral deposits.
Clean/disinfect tank as instructed in
cleaning instructions.
BWM5251-I_10MLM2.indd 7-8BWM5251-I_10MLM2.indd 7-8 4/26/10 3:48:45 PM4/26/10 3:48:45 PM
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bionaire BWM5251 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info