Power Supply
48V battery charging procedure (power supply)
Connect the power supply and the battery by
inserting the charge connector into the TOUCH PORT
– the BionX system can be on or off
Connect the power supply to a power receptacle
The battery TOUCH PORT (LED ring around the
charge connector) lights up red upon insertion and
then turns to amber during the charging process
When fully charged, the colour of the LED ring
changes to green. The battery charging process is
then complete
• Following this procedure the charging connector should be disconnected from the battery
• During the charging process you can check the battery state-of-charge through the console if the
battery is connected to the system – a 48V system can be switched on while it is charging
This has my vote :)
Battery state-of-charge Colour
100-75 % Green
75-20 % Amber
< 20 % Red
Checking the 48V Battery state-of-charge
• Swipe your finger slowly over the TOUCH PORT
• Battery state-of-charge LED will illuminate
• Allow ten (10) seconds before checking state-of-charge again
NOTE
The power supply is suitable for line voltage ranges of 110-115V or 220-230V, and com-
pensates automatically. The 48V battery is designed to be charged by a 26V BionX power
supply. The battery has an integrated charger which permits the use of a small, portable
power supply.
Ensure that a completely charged battery is no longer connected to the power supply after the charge
procedure is completed.
TOUCH PORT green =
fully charged
TOUCH PORT amber =
charging
TOUCH PORT red =
upon insertion
It is best to store the battery in a cool location at temperatures between 10 °C (50 °F) and 25 °C (77 °F).
Never store the battery in locations where the temperatures can reach more than 45 °C (113° F) or
fall below -10 °C (14 °F). The battery should never be exposed to extreme temperature fluctuations
or humidity, and always protect the battery during storage from humidity to prevent corrosion of the
connectors. Never drop the battery. Always protect it from physical damage. Damage may lead to short-
circuits, and as a result cause overheating of the battery.
Do not dispose of used batteries in regular household trash, be aware that used batteries
must be disposed of properly! BionX batteries can be returned to BionX to be recycled.
WARNING
The BionX power supply/charger should be used exclusively for BionX rechargeable
batteries of the specified type. Keep the power supply or charger away from water or
moisture when charging and/or connected to prevent electrical shock or short-circuits.
Do not use a power supply or charger that has obvious signs of damage to the cable,
housing, or the connector.
Extreme temperatures will affect battery life, especially during charging. Avoid charging in direct sunlight
or in very hot or cold temperatures as this will reduce the life of the battery considerably. We recommend
charging the battery at room temperature (approximately 20 °C / 68 °F). The battery should be warmed to
room temperature before it is charged, particularly if it was exposed to cold temperatures during a ride.
The battery can be charged when mounted on the bicycle or removed from the docking station.
A Lithium Ion battery does not have a memory effect, which means that the battery’s maximum energy
capacity is not affected if it is repeatedly recharged after only being partially discharged. The battery does
not need to be completely drained before charging. We recommend charging the battery after every ride,
preferrably when the state-of-charge display shows less than 50%. When the battery is fully depleted it will
signal that a recharge is needed by beeping. The battery is fully charged after approximately 4 to 5.5 hours.
CAUTION
All classic BionX batteries must be charged when not in use for a long period of time (i.e.
before winter storage) and then must be charged at minimum every three months. Not
charging the battery can lead to potential damage of the battery cells. This is a lack of
maintenance on behalf of the owner, which can incur a loss of warranty.
NOTE
New 48V BionX batteries are equipped with “Deep Sleep” mode, a function that preserves battery
energy depending on either the state of charge or significant inactivity. A fully charged battery will
automatically enter Deep Sleep after 2 months, while a partially discharged battery will enter it in
increasingly faster time frames. This results in minimal energy consumption during standby and enables
a shelf life of up to 6 months for a fully discharged battery, and up to 18 months for a fully charged
battery. To activate a battery that has entered Deep Sleep mode, connect it to the 26V BionX power
supply and allow it to complete a full charge cycle. BionX still recommends charging these batteries at
minimum every 6 months.
english
english
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für BionX D-series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von BionX D-series

BionX D-series Bedienungsanleitung - Deutsch - 18 seiten

BionX D-series Bedienungsanleitung - Französisch - 17 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info