669274
9
Zoom out
Zoom in
Vorherige Seite
1/10
Nächste Seite
IMPORTANT: Be sure to use BISSELL Hard
Floor Solution when cleaning sealed hard
floor surfaces.
4. Place solution tank back in the machine.
5. Attach Microfiber mop pad to quick dry
hard floor tool by attaching ends to Velcro
strips on top of tool.
6. Attach quick dry hard floor tool to end
of the wand.
7. Plug into a proper electrical socket and
push heater, power and wet clean buttons on.
8. Place tool directly on the hard floor
surface, resting on the pad.
9. Press spray trigger to moisten mop pad
with cleaning solution.
Caution: Do not oversaturate.
10. Move tool back and forth across floor;
using solution, brushes and mop pad to
clean. Press spray trigger as needed.
11. With the spray trigger released, tilt the
tool forward and pull back across cleaned
floor to remove any residual water. This will
create the best suction and will help get the
hard floor surface as dry as possible.
12. Continue to clean entire floor.
13. When finished, be sure to remove
Microfiber mop pad and clean by hand
or machine wash as needed. Allow to
dry completely before next use.
14. Refer to section D for machine care
instructions.
D
Care,
Maintenance & Storage
D-1 Machine care
1. Push heater, power and wet clean buttons
off. Unplug machine.
2. Open Quick Release™ hose door and
remove collection tank by lifting straight up
using tank handle.
3. Remove top lid from collection tank, rinse
and air dry.
4. Empty dirty water into a sink, toilet or out-
side by pouring dirt water out from corner of
tank. Rinse inside of collection tank.
5. Remove mode selector by turning to
“REMOVE” and pulling straight out.
6. Once model selector is removed, remove
water filtration tower by lifting up and rotat-
ing clockwise so front of tower is facing side
of collection tank. Then pull up and out
of collection tank.
7. Rinse collection tank, mode selector and
water filtration tower. Allow to air dry com-
pletely before replacing water filtration tower
and mode selector back into collection tank.
a . To replace filtration tower back
into collection tank, drop into top of
collection tank and rotate counterclock-
wise so front of tower is facing front of
collection tank. Be sure to align with
tabs in bottom of collection tank.
b . Once water filtration tower is
replaced, replace mode selector by
inserting back into front of machine.
Make sure mode selector is in
“REMOVE” position when inserting back
into machine. Turn either clockwise to
“FILTER VAC” or counterclockwise to
“WET CLEAN” to lock back in place.
8. For wet cleaning, remove all tools that
were used and rinse with clean tap water.
Allow to dry completely before storing.
9. Remove hose, taking care to keep both
ends up to avoid spilling. Empty out
any remaining water and rinse clean with
clean tap water. Allow to dry completely
before storing or placing back on machine.
D-2 Maintenance
1. Pre-motor filter: Remove from top lid by
pulling tab away from separator and pull-
ing straight out. Inspect foam filter. If dirty,
rinse with clean tap water and allow to dry
completely before replacing back into sepa-
rator. To attach separator back onto to top
lid, line up “T” pieces under shallow grooves
on top lid and push together until tab clicks
together.
2. HEPA Media filter*: Remove filter door by
pressing down on latch and pulling down.
Once filter door is open, place one hand on
each side of filter and pull it out of machine.
If dirty, replace with new filter or rinse under
clean tap water and allow to dry completely
before replacing back into machine. Be sure
filter door is fully closed and latched prior to
operating machine.
D-3 Machine storage
Water and cleaning formula can be left
in solution tank for next use.
1. Wrap power cable around cable wrap
on back of the machine.
2. Store unit in a protected, dry area, at
room temperature (4° to 43° C).
9
www.BISSELL.com
WARNING
to reduce the risk of fire and
electric shock, always install float
before any wet pick-up operation.
*The filter media, not the vacuum as a whole,
complies with the IEST-RP-CC001.5 HEPA standard.
Downloaded from www.Manualslib.com manuals search engine
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bissell HYDRO CLEAN COMPLETE 81N7 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info